Loading…
Loading…
62,426 results • Best match
Maintenance of 35 KVA DG Set at Rajendra Nagar Zonal Office Building in Rajendra Nagar division (19) and Circle-19 of Rajendra Nagar Zone, GHMC
Providing of temporary lighting 225 nos of 120 W LED for 2 days (18-02-2026 to 19-02-2026) at Surroundings Shivaji Maharaj bridge and Imlibun park in Dabeerpura division (81) in Yakuthpura Circle and Constituency in view of Shivaji Maharaj Jayanthi.
Repair/Renovation and Electrical work in ATS Tarsara Varanasi.
Repair/Renovation and Electrical work in ATS Tarsara Varanasi.
Electrical Sub Station work at New Hospital, Pali
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Provision of ILS at Tuticorin Airport SH External Electrical Works
Supply, Installation, Testing and Commissioning of outdoor type totally enclosed MV LT panel, degree of enclosure protection shall be IP 55 as per IS 13947 ([part-I), with front and back openable arrangement completely made up of i/c internal partitions of 14 SWG CRCA sheet steel, i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, dust tight, vermin proof totally enclosed, cubicle type floor mounting, free standing including providing and fixing of extensible type 200 A Aluminium bus bar with all accessories suitable for operation at 415V, 3 phase, 4 wire, 50 Hz, A.C power supply system complete with all accessories, interconnection with solid Aluminium strip neutral links, earthing, painting, grouting, providing cable entry provision, cable chamber control wiring with 1.5 sq.mm PVC insulated FRLS copper conductor single core multistrand cables, cable gland plates, danger notice plates etc. as required and mounted with the following switch gears as per technical specification required and comprising the following : INCOMER 200 A, 25 kA, 4P MCCB with Microprocessor based releases for short circuit, overcurrent as incomer with R,Y,B,ON,OFF, Trip indication lamps, resin cast CT's with 3 phase multifunction meter with RS 485 (for V, A, kWH, kW, PF, Hz, kVA & THD - L&T WL 5010 or equivalent), double SPD for redundancy- 2 sets as incomer suitable for terminating incomers of2 runs of 3.5 core 400 sq.mm with suitable spreader links(suitable cable termination chamber are to be provided withour any extra cost). Buscoupler 200A, 25kA 4P MCCB without relase OUTGOINGS a) 63 A, 25KA, 4P MCCB with microprocessor based releases for SC &OC with resin cast CTs, digital Ammeter, ON, OFF, Trip indication lamps as outgoing - 3 set as outgoing. b) 200A, 25KA, 4P MCCB with microprocessor based releases for SC & OC with resin cast CTs, digital Ammeter, ON, OFF, Trip indication lamps as outgoing - 1 sets as outgoing. c) SPARE compartments suitable from MCCB rating of maximum 63Amps - 1 no.
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Commercial; Electrical System or Installation, Augmentation works of 11 KV DTs under Business Plan 2026-27 against Tender no 20 2026-27; As per BOQ
and Installation of Plant Systems/Equipments (Version 2) - Commercial; Electrical System or Installation