Loading…
Loading…
59,304 results • Best match
PreMonsoon Maintenance repair work of electrical installations such as switchgear transformer VCB HT Relay ACB MCCB LT Starter control panel including allied works of VT pumps and routine maintenance of 33KV substaion at Bagjola pumping station
Servicing and overhauling 2500 / 1600 /1250/1000 Amps A.C.B. after withdrawing the breaker from its track, complete servicing the breaker, cleaning, moving and fixed contacts and adjustment incl.mechanical lever, greasing, oiling etc. and disconnection of the armoured cable and cleaning the surface with carbon tetra chloride, marking cloth, emery papers and applying of petrolium jelly etc. to the socket terminals and taping with PVC tapes and re-connection of the same as per direction of E.I.C.
Electrical Renovation / Electrification Works for Electrical Machines Lab-1 at the Electrical Engineering Department, IIT Roorkee
Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light (System Lumen efficiency>=135) of Powder coated die cast/ Extruded aluminium body (thickness>=1.20mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 Hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5-year OEM warranty. System lumen efficacy ≥135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)
Electrical AC Work
Work Name:GENERAL-PWD Rest House North Paravur - 4 Nos Split AC installation- SITC of 4 Nos 1.5 TR Split A/C units in three rooms on the first floor and one room on the second floor of PWD rest house North Paravur -Electrical AC Work
Construction of auditorium including public health and electrical works at university college benra, Dhuri, Distt Sangrur Work Code-SGR-2026-016
eProcurement System Government of Punjab Created By: Lalit Kumar Created Date/Time: 04-May-2026 01:19 PM Tender Title: Construction of auditorium including public health and electrical works at university college benra, Dhuri, Distt Sangrur Work Code-SGR-2026-016 Tender ID: 2026_DOA_162402_1
Laying of 5.5 Km HT UG Cable from Venpalavattom to Munnamanakkal KRFB works in connection with road widening of Petta Anayara road under Electrical Section, Petta under Electrical Division, Kazhakoottam
GENERAL-Tax Tower, Karamana, Tvpm- Renovation works in Commissioner office room and flooring works-Rearrangement of firefighting facilities.-Electrical Fire Fighting Work
17.5.2:CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.