Loading…
Loading…
6,166 results • Best match
Design, Supply, Installation, Testing and Commissioning of 1000 Kg Per Hour capacity Mechanized Windrow Composting unit at Fruit and Vegetable Mandi Potushay, Bandipora under HADP.
Fabrication, Providing and Fitting of Segregation Table fabricated out of SS-304 material for segregation of organic waste along with (6 No’s) of HDPE Dustbins as per Technical Specifications.
Construction work of drain at municipal area ward no 01 to 27
Providing & Fixing in position, MS fabrication work using angles, sqr tubes, c channels etc for various partition frame as per Design & Instructions & Complete in all aspects . including all materials labour, finishing etc complete
construction work of drain at municipal area ward no 28 to 55
Providing & Fixing in position, MS fabrication work using angles, sqr tubes, c channels etc for various partition frame as per Design & Instructions & Complete in all aspects . including all materials labour, finishing etc complete
Supply and Delivery of Various Stages (03 Nos) Submersible Motor with Suitable Starter at Kakavedu in Ward No.02, (10 Nos) 5HP Submersible Motor with Suitable Starter at a) Rasappa Colony in Ward No.05, b) Ngaari D/w in Ward No. 06, c) Netham ST Colony in Ward No.09, d) Prakash Nagar Ward No.15, (01 No) 40HP Vertical turbine Pump Motor at SS Tank and (20 Nos) 7.5HP Submersible Motor with Suitable Starter, Materials at a) NTR Nagar in Ward No.13, b) EKM Kamaraja Street in Ward No. 14, c) Karakantapuram D/w in Ward No.17, d) Sathrawada SC Colony in Ward No.20, e)Sanjivee Nagar in Ward No.24, f) Gandala Street in Ward No.26, Chinthalapatteda D/w in Ward No.27 g) Raja Street Chinthalapatteda in Ward No.28, h) Chakala Street in Ward No.29 in Nagari Municipality
Fabrication ,transportation and and supply of wall mounted control panel board of size 600x600x250mm made of 18 SWG CRCA sheet steel enclosure, 14 SWG mounting plate for cable entry fabricated , painted with two coats of Red oxide primer and two coats of Grey paint, lock and key arrangements two side louvres with weld mesh inside etc., complete consisting of the following equipment with all internal wiring using L&T / Finolex copper FRLS cables of suitable size and capacity and cable clamp etc complete for 3 phase motor pump sets. Makes: As per list of recommended brands. Voltmeter ; 0-500 V 96x96mm size. 0 to 20 Amps / 0 50 Amps Ammeter (96x96mm size)-1No. Single phase preventor of suitable range - 1No. 32 A TP, 10KA MCB. - 1No Indication lamps (R-Y-B) with switch control - 1set Voltmeter & Ammeter selector switch - 2 Nos Supply and fixing of ISI Mark suitable capacitor ELEC-5.4.17
Restoration of rain damages of LWSS Manai Pargod under Section Manai Sub Division Manai in Tehsil Harchakian Distt, Kangra, (HP)
Laying ,jointing, with circumferential butt joints by electrical arc welding & flanged pipes with 5% flanged joints and remaining 95% with butt welding(Welding thickness shall be equal to pipe wall thickness) and testing of G.I Pipe of approved store issued rate make of following diameter confirming to IS:1239:1990 (Part-II) (latest with up to date amendments having wall thickness as specified below capable of withstanding required test pressure , including manufacturing and fabrication of reducers taper all shorts pieces, bends etc as per site requirement made from parent tubes. The laying of pipe shall also include flanged joints duly welded in three layer (one inner and two outer) Where ever required as per direction of Engineer in charge (Earth work in trenches and the cost of flanges i/c nut and bolts gasket will be measured and paid for separately) and all operation such as cutting welding and jointing fabrication of bends tees i.e lowering and laying in excavated trench to ensure required level including flushing cleaning and hydraulic testing complete in all respect to the entire satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The welding electrodes shall be as per IS 814 of Advani Overlikon/Over cord s/s make. The rates also includes entire carriage of material ,flushing, Cleaning and Hydraulic testing,DP test of butt welded joints complete in all respect and to the entire satisfaction of Engineer in charge with in all leads and lifts
Restoration of rain damages of LWSS Manai Pargod under Section Manai Sub Division Manai in Tehsil Harchakian Distt, Kangra, (HP)
Laying ,jointing, with circumferential butt joints by electrical arc welding & flanged pipes with 5% flanged joints and remaining 95% with butt welding(Welding thickness shall be equal to pipe wall thickness) and testing of G.I Pipe of approved store issued rate make of following diameter confirming to IS:1239:1990 (Part-II) (latest with up to date amendments having wall thickness as specified below capable of withstanding required test pressure , including manufacturing and fabrication of reducers taper all shorts pieces, bends etc as per site requirement made from parent tubes. The laying of pipe shall also include flanged joints duly welded in three layer (one inner and two outer) Where ever required as per direction of Engineer in charge (Earth work in trenches and the cost of flanges i/c nut and bolts gasket will be measured and paid for separately) and all operation such as cutting welding and jointing fabrication of bends tees i.e lowering and laying in excavated trench to ensure required level including flushing cleaning and hydraulic testing complete in all respect to the entire satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The welding electrodes shall be as per IS 814 of Advani Overlikon/Over cord s/s make. The rates also includes entire carriage of material ,flushing, Cleaning and Hydraulic testing,DP test of butt welded joints complete in all respect and to the entire satisfaction of Engineer in charge with in all leads and lifts