Customized AMC/CMC for Pre-owned Products - Annual Maintenance Contract (AMC) for Mechanical Systems and Fire Fighting Systems for 3-years including Incidental Supplies and On-Demand Services, IOCL owned products; IOCL owned products; Annual Maintena..
Customized AMC/CMC for Pre-owned Products - Annual Maintenance Contract (AMC) for Mechanical Systems and Fire Fighting Systems for 3-years including Incidental Supplies and On-Demand Services
Comprehensive Annual Maintenance and Operation of Fire Fighting System, Fire Alarm System and Water Supply System up to Terrace with Pumps Installed at NVDA, Narmada Bhawan, Bhopal for the Year of 2025-26
Comprehensive Annual Maintenance and Operation of Fire Fighting System, Fire Alarm System and Water Supply System up to Terrace with Pumps Installed at NVDA, Narmada Bhawan, Bhopal for the Year of 2025-26.
Comprehensive repair and maintenance of 1 MW Solar Power Plant under GE (E) Jalandhar Cantt
Supply and installation in repairs, commissioning and testing polycarbonate ASTA CPRI approved OEM made DC SMB (24 IN 1 OUT) outdoor type Floor Mounting type (Mini. Size 2550x1450x255mm). The DC SMB Isc : 18.5A, SYSTEM VOLTAGE : 1000V DC shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES shall be DESIGN TEMPERATURE: 50 degree centigrade , DESIGN STANDARD: IEC 60 364-7-712, UV resistance, anti-acid, anti corrosive and FR material.The manufacture of DC SMB shall submit a copy of CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGRRE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITHIEC 60529 and the gasket shall be internally embedded made of polyurethane. The Panel Should be mounted on angle legs of size 40mm x 40mm legs with Gound clearance 450mm duly spray painted internally and externallywith two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1(using 20 mm graded stone aggregate) including all provision of opening for nincomming Bus Bar Rating 30x10mm (TIN COATED CU)/outgoing 50x10mm(TIN COATED CU). The DC SMB Cable Size I/c-1Cx 6SqmmCAble - 48nos (Spare 4 Nos), RS 485-2Cx1.5Sq.mm Cable-1 No and O/G 1Cx300Sq.mm Cable-2Nos, Earthingfor SPD 1Cx16Sq.mm Cable-1 No made by aproved Hensel, ABB,Schneider & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel as per following. a). 1. In accordance with IEC 60 439-1 (IS8623) at ASTA ( CPRI Bhopal Laboratory ) and IEC 61 439-2 for powerswitchgear and controlgear assembly. The type test report as per CPRI ( in accordance with IEC 60 439-1 ) should consist with following: i) Degree of protection of system ii) Temperature Rise Limit iii) Dielectric Properties (iv) Short Circuit Withstand Strength (v) Effectiveness of protective circuit (vi) Clearance and creepage distance (vii) Mechanical Operation (b). Glow wire test at 9600C in accordance with IEC 60 695-2-11 UL subject 94, should be flame retardant and self- extinguishing in nature, so that fire should not be spread all over in the event of fire due to short circuit (c).Degree of protection against mechanical load IK 08 (5 Joule) ) in accordance with accordance with EN IEC 62262 (d). Rated insulation voltage should be 690Vac / IEC 1000 Vdc as per IEC 60664 (e). UV-resistance in accordance with IEC 61 439-1, Clause 10.2.4: The material is examined for UV resistance. INCOMER:- 500A , FP 1000V DC Isolator with Direct Handle, B.B - 01 No - Make Socomec, Auxiliary contact - 01 No Make Socomec, 40A, 1000V DC Diode With Heat sink - 24 Nos, 1000V/24VDC Power Supply Unit [DC/DC Converter] - 1 No., 1000V DC Surge Arrester, Type ll With FM - 01 No, Surge Protector for ataline(DLA-12D3 Type) - 01 No, Hall Based String Monitoring PCB/Card with RS 485 MODBUS - 1 No, String Monitoring PCB/Card (Slave) - 2 Nos., Voltage Monitoring device - 1 No, 3A,1000V DC Fuse Link - 2 Nos,.30A, 1000V DC Fuse Link - 24 Nos, 32A, 1000V DC Fuse Base without Indication - 26Nos. Providing the suitable Terminals, Internal wiring 6Sq.mm Cable Diode terminals + VE Diode +VE fuses NOTES:) Contractor shall the test reports & drawing. 2. M&L for REVA Type 1+2 AC SPD 3AYNPV1500-SPD5 - Each - 2 3. Supply and fix 6 sqm Solar DC Cable Each 200 4. Supply and fis Solar pnel MC4 Y Connector Each 20 5. Supply and fis Solar pnel MC4 YConnector RM 42
COMPREHENSIVE REPAIR/ MAINTENANCE OF CENTRAL AC PLANT 3 X 100 TR AT AF STATION HALWARA UNDER GE (AF) HALWARA
Comprehensive maintenance of chillar plant of capacity 3 Nos x 100 TR water cooled screw chiller operating on R-134 A Refrigerant with unit mounted starter panel complete with all accessories, Make - Voltas Model No ACEEWFXR 1001 ML B2-W/C. The Job includes the following scope of work :- (a) Carrying out quarterly inspection of equipment as mentioned above. As a part of Preventive maintenance (PM) in accordance with relevent PM check lists and as per schedules that will be prepared upon activation of contract. The salient features in theses check lists are as follows: - (i) Checking the central AC or refrigenration system and equipment such as compressors and their electrical controls on the repective equipment. (ii) Checking the refrigeration system for any leaks. (iii) Checking the electrical and refrigeration control system for operation and adjustments of set valves as necessary. (iv) Lubrication of all necessary points in the system & its components in line with the check lists. (v) Changing of parts (Not whole units such as chiller, control panel, reciprocating compressors, screw compressors, centrifugal compressors, motors, VFD and the like) or repairing or re-calibration as may be necessary. (b) Carrying out :- Once in a year, chemical or manual (Tube brushing) de-scaling of water cooled condensers. (i) Chemical de-scaling will not be done when manual brushing of condenser tubes will suffice this enhances the life of the condenser. (c) Carrying out chemical or manual (Tube brushing) de-scaling of evaporator. (d) Carrying out :- Once in a year testing of lubricant and water. (e) Part and consumables will be provided free of charge in normal circumstances. (f) Handing over of annual report for improvement if any at the termination of CAMC. (g) Attending to breakdown on call within 12 hrs from the time of intimation verbally/ telephonically. If the breakdown is not attended/ rectified on time the penalty of Rs. 1000/hr shall be charged till the time fault is rectified.
Customized AMC/CMC for Pre-owned Products - 9030C26A24 Expert Technical Services for maintenance of Velan Valves installed in DCU at Gujarat Refinery; As Per SSC-T; Annual Maintenance Contract (AMC); As Per SSC-T; No
Customized AMC/CMC for Pre-owned Products - 9030C26A24 Expert Technical Services for maintenance of Velan Valves installed in DCU at Gujarat Refinery; As Per SSC-T; Annual Maintenance Contract (AMC); As Per SSC-T; No
Annual all in all Comprehensive maintenance Contract of Air Conditioners installed in various buildings of Kota University of Kota for the one year
All in all comprehensive maintenance of various type air conditioners After Defect Laibility Period of Equipment including repair/replacement of compressor, condensing/ cooling coil, refrigerant piping, fan motor, remote, charging of refrigerant when ever required and periodical servicing as per EIC recommendations to meet out the efficient performance of the equipment. 1.0/1.5/2.0 Tr window type air conditioner