| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹13.4 LAdmitted-Finance | -25.80% | ₹13.4 L | L1 | Admitted-Finance |
| 2 | L2₹15.5 LAdmitted-Finance 00 VIBHAV NAGAR COLONY NAVIPUR KALAN NAVIPUR KALAN HATHRAS UTTAR PRADESH 204101 | HATHRAS | UTTAR PRADESH | 204101 | -14.21% | ₹15.5 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical Non responsive |
Tender Value
₹18.1 L
EMD Value
₹36,120
Closing Date
22 Apr 2026, 5:00 pmClosed
REGISTRAR
UNIVERSITY OF KOTA
Annual all in all Comprehensive maintenance Contract of Air Conditioners installed in various buildings of Kota University of Kota for the one year
2026_UOK_551264_1
02/2026-27
Open Tender
Miscellaneous Works
Fixed-rate
365 days
KOTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
AS PER NIT
₹36,120
5 May 2026
13 Apr 2026
23 Apr 2026
13 Apr 2026
22 Apr 2026
13 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | All in all comprehensive maintenance of various type air conditioners After Defect Laibility Period of Equipment including repair/replacement of compressor, condensing/ cooling coil, refrigerant piping, fan motor, remote, charging of refrigerant when ever required and periodical servicing as per EIC recommendations to meet out the efficient performance of the equipment. 1.0/1.5/2.0 Tr window type air conditioner | - | Job per Year | - | - |
| 2 | All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair/replacement of compressor, condensing/ cooling coil, refrigerant piping, fan motor , remote, charging of refrigerant when ever required and periodical servicing as per EIC recommendations to meet out the efficient performance of the equipment.1.5/1.8/2.0 Tr Split type air conditioner | - | Job per Year | - | - |
| 3 | All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair/replacement of compressor, condensing/ cooling coil, refrigerant piping, fan motor, remote, charging of refrigerant when ever required and periodical servicing as per EIC recommendations to meet out the efficient performance of the equipment.1.5/2.0/3.0/4.0 Tr Cassette type Split type air conditioner 1.5/2.0/3.0/4.0 Tr Cassette AC Split/ VRB type air conditioner | - | Job per Year | - | - |
| 4 | All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair/replacement of compressor, condensing/ cooling coil, refrigerant piping, fan motor, remote, charging of refrigerant when ever required and periodical servicing as per EIC recommendations to meet out the efficient performance of the equipment.3.0/4.0/5.0 Tr Ductable type Split type air conditioner | - | Job per Year | - | - |
| 5 | SITC of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications including chase cutting, supports etc. as required.6.35 mm | - | RM | - | - |
| 6 | SITC of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications including chase cutting, supports etc. as required 9.53 mm | - | RM | - | - |
| 7 | SITC of Interconnecting refrigerant pipe work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications including chase cutting, supports etc. as required.12.7 mm | - | RM | - | - |
| 8 | S & F of rigid CPVC (20mm) drain piping of 6 kg/ cm2 with 6mm thick nitrile rubber insulation. | - | RM | - | - |
| 9 | S & F of rigid CPVC (25mm) drain piping of 6 kg/ cm2 with 6mm thick nitrile rubber insulation. | - | RM | - | - |
| 10 | S & F of FR PVC insulated & sheathed 3 core flexible copper conductor ISI marked (IS:694) of 1.1 kV grade of 4.0 Sq.mm rating: | - | RM | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
BOQ_982383.xls
BOQ • 0.29 MB
TenderDocument.pdf
Tender Documents • 1.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].