Loading…
Loading…
984 results • Best match
COMPREHENSIVE AMC OF FIRE ALARM, EBI AND VESDA SYSTEM AT DR CENTRE OF CMO BUILDING .
Shifting of Fire Alarm Panel from Control room at Basement to Security Room of Govt. Super Specality Hospital Jammu
1 Shifting of the existing Fire Alarm Control Panel from control room at basement to security room of Govt. Super Specaility Hospital Jammu. The job includes complete dismantling of the panel, safe disconnection of power supply and loops, and careful relocation without causing any damage to system components. The scope further includes extension of fire-resistant cables, re-termination of all circuits, and proper mounting of the panel at the new site . After relocation, the entire fire alarm system shall be reprogrammed, including configuration of all devices, zones, address loops, logic sequences, sounder circuits, and interface modules, ensuring integration with existing infrastructure. The job include complete testing and commissioning including device-wise loop testing, simulation of fire and fault conditions, and full functionality checks.The technician ensures that each device communicates properly with the panel, clears any loop faults, adjusts sensitivity levels where applicable, and restores all event logs and system parameters. Reprogramming of the Fire Alarm Control Panel and all connected devices must be done as per OEM guidelines, using authorised configuration software/tools, including updating of addresses, zones, loop mapping and cause-and-effect logic.After completing the reprogramming, the entire fire alarm system is tested device-wise to confirm proper operation, communication, and alarm response.The complete job includes cost of dismantling and shifting the existing Fire Alarm Control Panel ,cost of replacement of batteries , extension of fire-resistant cables, re-termination and mounting at the new location, complete system reprogramming, and full testing and commissioning, required materials, consumables, labour charges, and taxes. job Excess(+) Full Conversion INR
Custom Bid for Services - CAMC OF 8 HABDS AT TVC division for 2 years Sch 1 AMC charges for HABD at AFK ERN end (KM 80 200-300 from SRR) 8 Quarters, Custom Bid for Services - Sch 2-AMC charges for HABD at ERS C-Cabin (KM 1/880 from ERS)- 8 Quarters, ... of Fire Detection, ... Fire Detection , ... Detection, Fire Alarm, ... Fire Alarm , ... Alarm, Fire Hydrant ... of Fire Detection, ... Fire Detection , ... Detection, Fire Hydrant ...
Fire Hydrant and Sprinkler System AMC/CMC of Fire Detection
Customized AMC/CMC for Pre-owned Products - FIRE ALARM SYSTEM; PALLADIUM AGNI; Comprehensive Maintenance Contract (CMC); MONTHLY; No
Customized AMC/CMC for Pre-owned Products - FIRE ALARM SYSTEM; PALLADIUM AGNI; Comprehensive Maintenance Contract (CMC); MONTHLY; No
Fire agent Release control panel, Manual Gas Release Station, Manual Gas Abort Station, Auto dialer Module, Manual Call Point, Manual call point 2, Fire agent Release control panel2, 24 V DC electric actuator, 24 V DC electric actuator2, Optical ... type smoke detector, ... smoke detector , ... detector, Smoke Detector1, ... Smoke Detector1 , ... Sensor Smoke Detector ... Smoke Detector 2, ... Criteria Smoke Detector ... Smoke Detector Head3, ... heat detector4 , ... Criteria Smoke Detector ... Smoke Detector and ... Heat Detector5 , ... Hydrant fire Fighting ... valve, FIRE Hose ... Headed fire hydrant
Optical ionization type smoke detector
Plywood 06 mm, Exhaust Fan, Whiteboard, TV mount Stand 55 inch, Power Outlet, Fireball, Fire Extinguisher 5 Kg, Fire Alarm Panel, Floor Carpet 10 Ft x 15 Ft
Fire Alarm Panel