Loading…
Loading…
1,570 results • Best match
VEHICLE SPARE PARTS
Pulse Sensor of TATA HMV
Micro Controller based Electronic Speed Indicating,
Description :Micro Controller based Electronic Speed Indicating, Recording system along with Tacho Gene rator/Pulse Generator type MRT 918 to RDSO Specn No. MP.0.3700.07(Rev.07) august 2017 suitable for Va nde Bharat (Train 18). Accepted Firm`s Offer : Micro Controller based Electronic speed indicating, recording system Type MRT-918 for MAE675UV2, As per RDSO specification MP.0.3700.07 (Rev.07 no. or latest) Augu st 2017. Each set consisting of 4 items as followings (1) Recorder cum Indicator Unit-01 No./set. (2) Speed sensor ((PG- type 4S-60P (to be fi8ed at 1st Wheel axle box of DTC )) - 01 no./set (3) Junction Box- 01 no./s et (4) Connecting cables- 01 no./set. Make:-Medha Type MRT 918 only, Suitable for ICF-Medha 3-phase bas ed, vande bharat train-set Verson-2, Note:- Scale Range 0-200 kmph and voltage:110 V DC [ Warranty Pe riod: 30 Months after the date of delivery ] ] SSE/Tool Room/MW/NER/GKP, Uttar Pradesh 2.00 Set Consignee NER UVAM Item ref. ( Item Id :- 2201261 - Micro controller based Electronic Speed indicating and Recording system for Railway application ) Inspection Details Stage Inspection Not Required
Purchase of Electronics Lab Equipment
Arbitrary Function Generator: Frequnecy Range 0.1Hz-10Mhz Waveforms Sine wave, Square wave, Triangle wave, Saw tooth(±) and Pulse(±) Square-wave rise time: 35 ns Sine distortion: 1% (10 Hz – 100 kHz) Frequency response: ±0.5 dB (≤100 kHz), ±1 dB (≤5 MHz) TTL/CMOS output: 0.4V low, ≥3.5V high Output: Impedance: 50Ω±10% Amplitude: ≥20Vp-p (No load) Attenuation : 20dB /40dB DC bias 0-±10V (Continuously adjustable) Symmetry Adjustemnt: 90:10-10:90 VCF input 0-5V Frequency meter 1Hz-20MHz, error 0.003% Input max: 150V (AC+DC) Power: 220V ±10%, 50 Hz ±2 Hz Warranty: Should have 3 – year’s warranty.
TENDER FOR SUPPLY OF LABORATORY EQUIPMENTS andINSTRUMENTS
HPLC Module Pump(Quaternary Gradient) •High Precision dual plunger design. •System designed to work in micro , semi-micro analytical to semi prep scale •High speed double micro plunger in –parallel pump with automatic pulsation correction mechanism •Achieving pulse –free solvent delivery •Forced check valve designed for excellent solvent delivery control •Flow raterange:0.0001ml to 10.0ml/min each pump •Flow rate resolution of 3nl/step increment •Built in self diagnostic, Auto purge function •Flow precision is less than±0.06% RSD •Flow rate accuracy:±1% •Concentration accuracy±0.5% Washing kit Gradient mixer, Reservoir tray Quaternary Gradient unit DGU-20A5R BKL Degassing unit Manual injector: Rheodyne injector with 20 ul loop & mounting plate 25ul Hamilton syringe PDA Detector Wavelength 190 – 800 nm, Channel 512, Drift smaller than 0.5x10-3 AU/Hour, Noise smaller than 0.6x10-5 AU. Wavelength accuracy should be ±1 nm, Linearity: 2.0AU or more. A deuterium lamp [D2] and a Tungsten lamp [W] should be available as Light Source A Conventional HPLC flow cell [12 μL volume, 10 mm cell path length]. Lamp Replacement: Front access, Lamp Life Time : 2000 hours (D2 lamp) Controller alite system controller, Solvent bottles with cap 5/pkt, Chromatographic software
PURCHASE OF LAB ITEMS FOR ECE DEPARTMENT
Function Generator • Frequency range: 0.1 Hz to 5 MHz. • Display: 4 to 6 digit LED display. • Output waveforms: Sine, triangle, square, ± pulse, ± ramp. • Amplitude: 0–20 Vpp. • Rise time: 100 ns. • Distortion: 1% within specified frequency range. • Power supply: 230 V ac ±10%, 50–60 Hz. • Output amplifier protection: Short-circuit and ±15 Voverload protection.• DC offset: 0 to ±10 V adjustable.• Attenuation: 0 to –60 dB.
Procurement of Medical Equipment
Pulse Oxymeter Table Top