Loading…
Loading…
1,572 results • Best match
Lab reagents Equipments at CMHO Dungarpur
10 Pulse Oximeter each Excess(+) Full Conversion INR
mm SHAPED DORSAL DISTAL RADIUS LOCKING PLATE variable 3 holes in distal horizontal part and 3dash6 holes in longitudinal part with 4 x locking and 1 x cortical MRI safe, 2dot4slash2dot7 mm L SHAPED DORSAL DISTAL RADIUS LOCKING PLATE variable angle ... Disposable pulse lavage ... 160mm foot framecoma ...
Disposable pulse lavage system dot approvedslashregistered
Labour ward, Neonatal Opthalmic equipments for Kampli new 100 Bed Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
10 Item-10 PULSE OXIMETER 3 PARA. Itisusedforthetranscutaneousmeasurementanddisplay ofhaemoglobinoxygensaturation(SpO2).Thesignalsare produced by light-emitting diodes (LEDs) and received by aphotodetector.ThedevicedisplaystheSpO2valuesand may also measure and display pulse rate. Shouldbeaportable,lightweight,desktopmodelwith adult, pediatric and neonatal finger probes. Should have digital display with parameters: SpO2, pulserate,plethysmographwaveform,alarmmessage and battery state indication. SpO2detectionrangetoinclude:70–100% SpO2resolution:1%orless AccuracyofSpO2shouldbewithin+/-3% SpO2probesshouldbereusable. Pulse rate range detection range to include: 30-240 beats per minute (bpm). Pulserateaccuracy:within±3bpm. Pulserateresolution:1bpmorless Audio and visual alarms required: high and low SpO2 and pulse rate (operator variable settings), sensor disconnected, sensor failure, low battery.Suitablefordetectioninlowperfusionconditions. Shouldhaveaminimumof02hoursback-uptime. Shouldhavetrenddataofatleast36hrs.Digitaldisplayandeasilyaccessiblebuttonsto operate the machine. Lightweight 60dBA Shouldbedispersedthroughexhaust. 220V+/-10%AC,50Hz Yes,withminimumbackuptimeof02hour Tobespecifiedbymanufacturer Tworeusableprobeseachforadult,pediatricandinfant use Capableofoperatingcontinuouslyinambienttemperature of -10 to 60 deg C and relative humidity upto 90%in ideal circumstances. 03 years PreventiveMaintenancevisitsatleastonceineach quarter.Shouldprovide2sets(hardcopyandsoftcopy)of: User,technicalandmaintenancemanualsshould be supplied in English/Hindi language along with machine diagrams. Listofequipmentandproceduresrequiredfor local calibration and routine maintenance. Each 7.00 22299.08 156094
Set 5 KVA Kirloskar, Moving wheel for Genr Set 5 KVA Kirloskar, Injector for Genr Set 5 KVA Kirloskar, Cylinder Head valve grinding for Genr Set 5 KVA Kirloskar, Fuel Feed pump for Genr Set 5 KVA Kirloskar, Air Breather as approved for Genr Set 5 KVA ... Chilli, Oil Filter ... Kirloskar, Oil Filter ... Mahindra, Oil Filter ... Kirloskar, Oil Filter ... Kirloskar, Oil Filter ... Kirloskar, Oil Filter ... Harrison, Oil Filter ... Eicher, Oil Filter ... Honda, Pulser Coil ... Kirloskar, Oil Filter ... Kirloskar, Oil Filter ... Mahindra, Oil Filter ... Harison, Oil Filter ... Harison, Oil Filter ...
Oil Filter for Genr Set 30 KVA Kirloskar Oil Filter bracket open Make colon Luman forward slash Fleet Guard forward slash Donaldson bracket close for Genr Set 30 KVA bracket open Kirloskar bracket close
Supply of CONSUMABLES/NON-CONSUMABLES for the Department of PAEDIATRICS
FINGERTIP PULSE OXIMETER for SPO2 and pulse rate (Pediatrics). Specifications: 1). Should have Masimo signal extraction Technology and Measure-through motion and low perfusion technology 2). Should display perfusion index and pleth variability index 3). Should have soft material in the area of contact with patients finger tip
Supply of Miscellaneous articles, Anti-Covid Items, Electric articles and Different articles /items on Hiring basis for the West Bengal Assembly Election-2026.
Pulse Oximeter