Loading…
Loading…
1,573 results • Best match
Supply of Miscellaneous articles, Anti-Covid Items, Electric articles and Different articles /items on Hiring basis for the West Bengal Assembly Election-2026.
Pulse Oximeter
SUPPLY, INSTALLATION AND COMMISSIONING OF PROCESSING MACHINERIES FOR BANANA AUCTION CUM VALUE ADDITION CENTRE AT KALAKKAD BLOCK IN TIRUNELVELI DISTRICT
FOOD LAB EQUIPMENT SET Supply of Food Lab Equipment Set Such as Refractometer, Moisture analyte, water test , Egg tester
Supply of Ortho Implants
Pulse lavage
Blood testing & Office stationary related equipments for Kampli new 100 Beds Taluka Hospital, Ballari District under 2515-KKRDB (Macro projects) for the year 2024-25
10 Item-10 PULSE OXIMETER 3 PARA. Itisusedforthetranscutaneousmeasurementanddisplay ofhaemoglobinoxygensaturation(SpO2).Thesignalsare produced by light-emitting diodes (LEDs) and received by aphotodetector.ThedevicedisplaystheSpO2valuesand may also measure and display pulse rate. Shouldbeaportable,lightweight,desktopmodelwith adult, pediatric and neonatal finger probes. Should have digital display with parameters: SpO2, pulserate,plethysmographwaveform,alarmmessage and battery state indication. SpO2detectionrangetoinclude:70–100% SpO2resolution:1%orless AccuracyofSpO2shouldbewithin+/-3% SpO2probesshouldbereusable. Pulse rate range detection range to include: 30-240 beats per minute (bpm). Pulserateaccuracy:within±3bpm. Pulserateresolution:1bpmorless Audio and visual alarms required: high and low SpO2 and pulse rate (operator variable settings), sensor disconnected, sensor failure, low battery.Suitablefordetectioninlowperfusionconditions. Shouldhaveaminimumof02hoursback-uptime. Shouldhavetrenddataofatleast36hrs.Digitaldisplayandeasilyaccessiblebuttonsto operate the machine. Lightweight 60dBA Shouldbedispersedthroughexhaust. 220V+/-10%AC,50Hz Yes,withminimumbackuptimeof02hour Tobespecifiedbymanufacturer Tworeusableprobeseachforadult,pediatricandinfant use Capableofoperatingcontinuouslyinambienttemperature of -10 to 60 deg C and relative humidity upto 90%in ideal circumstances. 03 years PreventiveMaintenancevisitsatleastonceineach quarter.Shouldprovide2sets(hardcopyandsoftcopy)of: User,technicalandmaintenancemanualsshould be supplied in English/Hindi language along with machine diagrams. Listofequipmentandproceduresrequiredfor local calibration and routine maintenance. Each 7.00 22299.08 156094
supply of dental item equipment,instrument,minor equipment
Finger Pulse Oximeter
Rate Contract for Orthopedic Implants and Other Items
PULSE LAVAGE MACHINE