Loading…
Loading…
4,618 results • Best match
SUPLY OF MEDICAL EQUIPMENT FURNITURE AND LININ TO SDH AND MCH SAGARA-2025-26
Supply of Hospital Furniture and Equipment
Supply of Hospital Furniture and Equipment
Item
Hemodialysis Machine With RO Plant Technical Specification Equipment Specifications 1. Dimensions Height: 122 cm Width: 30 cm Depth: 37 cm 2. Weight Standard system Approximately 60 kg System with all options: Approximately 80 kg 3. Power supply AC (single-phase) 100 to 120V, or 200 to 240V 50/60Hz± 1 Hz Back-up battery: Ni-MH. battery, . 24V/500mAh 4. Water supply Pressure range of water supply 70 to 300 kPa (11 to 101 PSI) Temperature: 5 to 30°C 5. Dialysate flow. rate. (Qd) Setting. range: 300 to 700ml/min 6. Dialysate temperature Setting. range: . 30 to 40°C 7. Dialysate conductivity Bicarbonate conductivity Setting range: 1.5 to 7.0mS/cm Total conductivity Setting. range: . 12.5. to. 15.5mS/cm 8. Disinfection method Chemical, heat, or citric acid/heat 9. UF control system UF rate setting range: O or 0.1 to 4.0L/h Accuracy: ±30ml/h (Qd 300 to 500ml/min) ±0.1%. of .O d . (O d . 501 _ to 700ml/min) 10. Blood pump Flow rate setting range 40 to 600ml/min(blood tube's outer diameter 12mm, inner diameter 8mm); 40 to 350ml/min(blood tube's outer diameter 9.6mm, inner diameter 6.6mm 11. Air detector Ultrasonic, Sensitivity (blood flow rate 250ml/min) normal bubbles: 0.02ml micro .bubbles . (blood/air . mixture): 0.0003m. 12. Blood leak detector Optical, Sensitivity: 0.5ml blood/1 L dialysate (Blood: Hematocrit 20%, Dialysate temperature: 37 °C) 13. Monitoring Display Specifications (Measurement Range) Venous pressure -200 to +500mmHg TMP -100 to +500mmHg Dialysate pressure -600 to +600mmHg 1.Machine should have touch screen facility with customization of screen. 2.Machine should have sodium/UF/Bicarbonate profiling with 9 different modules . Machine should have 16 patients data storage facility. Machine should have facility to show complete flow diagram during disinfection and Test. Machine should have dialysate flow rate -300 to 700 mL/minute with incremental of 1 ml/minute. Machine should have heater capacity of 1500VA or less to save electricity. Performance (*Optional) • Single pump single needle (Click-clack) • UF/Conductivity profile • Concentrate nozzle rinse • Dialysate filter • Blood pressure monitor* • Network connection* • Blood volume monitor User Friendly Interface • Treatment settings data can be stored for up to 16 patients, eliminating the need to input data every time • Large graphic display for easy operation Safety • Continuous monitoring of pumps and valves during treatment Self test of extracorporeal blood circuit, hydraulic circuit, and CPU system before starting treatmen Detectors for blood, air bubble, and blood tubing lines Easy • Maintenance Flow diagram for checking the function of each part of the hydraulic circuit • Machine and treatment history data RO Plant – 250LPH
Supply of Hospital Lab Consumables
SUPPLY OF HOSPITAL LAB CONSUMABLES
Quotations for supply and Installation of ICU Ventilator to Dept. of Hematology, Rajiv Gandhi Govt. General Hospital, Chennai under ICMR Fund
Surgical instruments and equipment's. Personal protection system ( Steri -shield) Brand: Stryker (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687778507221 dt.18/0