Loading…
Loading…
947 results • Best match
Urgent repairing and installation of different Air Cooled Chiller units, Air Handling Units and distributioning of HVAC System at IAHVB
ARMO of various E and M Services for non-residential bldg and residential qtrs. at NASC Complex, Pusa, New Delhi. (SH:- Annual Comprehensive Maintenance of HVAC Plant.)
Up-gradation of Civil Hospital Naraingarh From 50 bedded to 100 bedded alongwith residential accommodation in Ambala District CM Announcement Code No 10020 (Pdg. Additional HVAC System) (Recall)
Sl. No. HSR Items / Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
Building Portion including Sanitary, Plumbing Water Supply System, Sewerage Drainage Work, Boundary Wall, Gate, Road Work, Electrification works, Firefighting Fire Alarm System, Medical Gas pipeline, Lift, HVAC, Drinking Water Supply (DWS) Work
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.
COMPREHENSIVE MAINTENANCE CONTRACT FOR HVAC (BLUESTAR MAKE) INSTALLED IN TEACHING BLOCK AT CHAUDHARY RANBIR SINGH
Providing services under Comprehensive Maintenance Contract for HVAC (VRF) System installed in C.V. Raman Bhawan( Teaching block-II) at CRSU, Jind Technical Specification : Make - Blue Star Limited Model No. IVRFB -10 TH ( 20 TR) – 2 Nos. IVRFB -18 TH ( 72 TR) – 4 Nos. IVRFB -20 TH ( 60 TR) – 3 Nos. IVRFB -20 THN ( 20 TR) – 1 Nos. IVRFB -22 TH ( 616 TR) – 28 Nos. IVRFB -22 THN ( 44 TR) – 2 Nos. The work shall be executed at as per “ Special Conditions and Scope of Work” given in DNIT. Rates to be quoted for Two (2) Years CAMC period
Repair and Maintenance of HVAC System installed in 500 Bedded Hospital Dr. RPGMC Kangra at Tanda for the year 2025-26