Loading…
Loading…
2,146 results • Best match
PROVN OF CERTAIN EXTERNAL WORK SERVICES AT BLAST PEN AT S AND K LINK AT 4 WG UNDER GE (AF) TECH AREA AT AF STN AGRA
M&L for Digging/Trenching, excavation not less than 1.7 mtr depth and 0.4 mtrs width in any type of soil including spreading and leveling of dry river sand 15cm under and 08 cm over OFC cable and laying of old size bricks class B perpendicular to cable across the cable on complete excavated lenth over of OFC as per BSNL norms including returning filling in and removing surplus excavated materials in low lying area complete all as specified and directed.
Shifting of CCTV system
Fiber optical cable splicing complete with testing commissioning etc as reqd.
supply of mobile aluminium tiltable tower ladder
Internet Lease Line of 1 Gig Bandwidtch (Optical Fiber 1 Gig) (Yearly Basis)
MICROTUNNELING AND PIPELINE INSTALLATION ACROSS SONG-2 RIVER CROSSING UNDER HARIDWAR-RISHIKESH DEHRADUN PIPELINE (HRDPL) PROJECT
All activities pertaining to transport of OFC from Clients's designated store to bidder's store and from bidder's store to site location, Blowing / Laying of optical fiber cable in each of the laid 40 mm HDPE telecom duct (after testing of OFC drum at site) , blowing/ Laying of OFC cable has to be done in both the ducts, testing of OFC before Blowing/ laying, cable sealing etc. using all materials required complete as per specifications and drawing provided in the bid document & as per direction of EIC. (spare loop of 20 Meter at Blowing Pit, 30 Meter at Jointing Pit shall be provided). The Optical Fibre Cable shall be free issue to the contractor.
Installation of C CTV at various locations in Marutharoad Grama Panchayath (Project No 165)
Supplying and drawn of 6F Armored OS2 optical fiber cable,(with High carbon stay wire with all require accessories ) Single Mode,9/125 - micron promary coated buffers, 9/125/250 (OS2) micron (OS I is not accepted), Cortugated Steel Tape Armour, BELLCORE GR 20/IEC 794-1, Water Swellable Glass Yarm, Attenuation @1310nm &It;0.34 db/KM MAX - @1550nm <0.22 db/KM MAX, HDPE Outer Sheath, THIXOTROPIC Loose Tube Gel, Corrugated Steel Tape, Armouring Type, & gt; 0.15 Armouring Type Thickness, PBTP Loose Tube Material, BlackJacket Colour, 2.8mm Loose Tube Diameter, 2.0mm Jacket Nominal Thickness, 1250 N Tensile Strength
Upgradation of Dedicated Internet Leased Line Connectivity and Allied Infrastructure for The Centralized Internet Service for Different Offices under Public Work Department at 45, Ganesh Chandra Avenue, 3rd floor, Kolkata - 700 013
Installation, Testing and Commissioning of 100-MB/s (1:1) Dedicated Internet Leased Line Connectivity (Backup Feed) including all accessories. [Location: P.W.Dte. IT Server Room, at 45, Ganesh Chandra Avenue, 3rd floor, Kolkata - 700 013; Interface Required: Ethernet Media: Through Single Mode Optical Fiber Cable (OFC) only and which will be Owned by Service Provider] [DILL Condition: Throughput: 100% Non – blocking (after Firewall); Packet Drop: 0.5 %; Network Uptime: > 99.5 %; RTD: Less than 300 ms; MRTG: Online] IPS service provider has to provide WAN as well as LAN IP of (/29 subnet) Public IP Pool. Additional Terms and Condition given in NIT Documents.