Loading…
Loading…
2,150 results • Best match
As per BId doc
Laying of OFC Cable along with GI pipe
RE-TENDER FOR SUPPLY OF VARIOUS DEPARTMENTAL EQUIPMENTS TO ESI HOSPITALS AND DIAGNOSTIC CENTRE.
4 ENT ENT NASAL ENDOSCOPE 0- DEGREE WITH COLD LIGHT SOURCE AND OPTICAL FIBRE CABLE - 1 - - - - 1
NOTICE INVITING e-TENDER FOR PROCUREMENT OF EQUIPMENTS, INSTRUMENTS,MACHINERIES, TOOLS ETC. FOR MALDA POLYTECHNIC, MALDA
CABLE FOR STUDY OF RUBBER, PVC,XLPE,FRS,FRLS,SUBMERGED FLATCABLE,INSTRUMENTION CABLE,COMMUNICATION CABLE,CO-AXIAL CABLE,OPTICAL FIBER FOR PVC & XLPE CABLES: VOLTAGE RANGE 66/132 /220 KV WITH ARMOURING ,X SECTION : 95 SQUARE MM ONE PIECE OF STANDARD LENGTH FOR EACH CABLE( 10 Types)
Implementation of Smart Water Management System for Tezpur 24 x 7 Water Supply Project Phase I under Amrut 2 in Assam including 5 years Operation and Maintenance on EPC Mode
OFC: Supply and Laying of 12core unarmoured Optical fibre cable (OFC :fiber glass with F-G 62.5/125micron, 2.6DB/KM F600) to various sites through HDPE pipe, prelaying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through previously laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ SiteEngineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer.
LAYING AND ASSOCIATED WORKS FOR GAIL-VIJAIPUR TO NFL-VIJAIPUR PIPELINE
Blowing of Optical Fibre Cable inside HDPE Duct : All activities pertaining to Blowing of Optical Fibre Cable in same pipeline trench directly (after testing drum at site), inside HDPE duct along the pipeline and OFC cable inside the duct at each side of pipe at all the crossings along the pipeline, sealing using all materials required as per specification.Testing of OFC before Blowing/laying, cable sealing etc. using all materials required complete as per specifications. (spare loop of 10 Meter at Blowing Pit, 20 Meter at Jointing Pit & 15 Meter at each station on wire-mesh (if applicable) shall be provided- No payments for laying shall be made for these spare loops) (Inside Plant: 3800 meter, Outside plant: 1000 meter)
nning, Maintenance and operation of Specialized Electrical and Mechanical Services installed at various residential flats near Lok Niwas Marg and Honourable LG Secretariate under M4512, Delhi. (SH-Addition/Alteration of existing Cisco make LAN System
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value 3.5 18 ps/nm-km and PMD value 0.2 ps/km and Cable Cutoff wavelength 1260 nm i/c splicing & marking etc complete as required. a) Single Mode 6 Core Optical fiber cable