Loading…
Loading…
2,141 results • Best match
Providing CCTV cameras to the Boundary and Parking area of AO Building premises
Supply of OFC cable including laying with materials required
Supply, Installation Testing and commissioning of surveillance system at DIHM Lajpat Nagar-IV, New Delhi .
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPESheath, Operating ambient Temperature should be – 5 deg C to +50 deg C and Storage Temperature shall be – 5 deg C to +50 deg C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm corrospondingly. The Dispersion value 3.5 18 ps/nm-km and PMD value 0.2 ps/km and Cable Cut-off wavelength 1260 nm etc complete as required. Single Mode 6 Core Optical fiber cable
Sub work. Provision of LAN, EPABX and CCTV arrangements in the Construction of additional buildings for MCH care in the Institute of Social Obstetrics Government Kasturba Gandhi Hospital for Women and Children in Triplicane in Chennai District
Supply and Installation of Optical Fiber 12 Port Patch panel. (DATA-A23)
Refurbishing of Reception of ER-3 at IIM Indore
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db/ km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value 3.5 18 ps/nm-km and PMD value 0.2 ps/km and Cable Cut off wavelength 1260 nm i/c splicing & marking etc complete as required.Single Mode 6 Core Optical fiber cable
Construction of Admin Block and Library Hall, Lecture Hall and Hockey Astrotruf Stadium at SUS Govt College Sunam Distt Sangrur (Electrical Services)
SITC of 6 Core Optical Fiber Cable Unitube Double Jacket Fiber Optic Cables Steel tape armor and PE jacket provide rodent protection along with improved crush and impact protection, Water blocking tape & Water blocking yarns over FRP, Working Temperature –40°C ~+60°C Speed 10 Gbps .Complete in all respect to the entire satisfaction of the engineer-in-charge
Construction of Entrance Canopy and Opening of 3rd Entrance Gate near SSPCC Building at ACTREC
SITC of 12 Core outside Optical Fibre cable corrugated steel tape armoured loose tube, gely filled, 9/125 micron single mode OS2 specification in trench cable tray/ clamping on wall with suitable clamps, saddles bolts, etc. through HDPE pipe including connections/terminations in distribution box (LIU's) in rack with connectors and couplers having the compliance/certifications for ISO 9001:2015 & ROHS.