Loading…
Loading…
2,208 results • Best match
Construction of Large Weigh Bridge (160 MT Capacity) in Block No. 4 at KUMS - Hanumangarh Town
Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR : 6 fiber
Supply and Installation of CCTV Camera
Cable laying charges (Cat6 Cable) (approx. 1525 mtrs) (In RMT)
SITC of Boom barrier,Bollard integrated with wave reader RFID tap Reader in RLA, Jaipur.
Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size.
Construction of Assistant Director, Agri. (Ext.) office building at Nokha (Bikaner)
Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR : 6 fiber
Const. of SE (M and P) wing at first floor and SE (DSM) wing at second floor of NABL Lab NPH, Jodhpur
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR25.0 Sq. mm 3.5 CORE E-11.1.5.3
TURNKEY WORKS OF SUPPLY INSTALLATION AND ASSOCIATED CABLING OF RACKS PANELS ENCLOSURE FOR DEVELOPMENT OF NEW NOCC SERVER ROOM INFRASTRUCTURE ALONG WITH THE ASSOCIATED JOBS OF SHIFTING OF GAILTEL SERVER ROOM NOCC MUX ROOM EQUIPMENT
SITC of Server Panel 42U 800 mm Wide x 2000mm (42U) Height x 1000mm Deep. Colour RAL 7035 light grey ,As per technical in SOW. Rack should have base frame of 100mm height for stability and PDU and Monitoring as per technical in SOW..As per technical in SOW. Along with Installation of Panels on stands/base frame of suitable thickness including all accessories for proper dressing and labelling and marking such as CABLE WRAP FOR DRESSING OF PATCH CORDs 12mm dia, cable ties cable glands, cable clamps etc. All the internal panel dressing shall be included in this SOR (As per technical specifications and functionalities defined in SOW)