Loading…
Loading…
15,542 results • Best match
CONTROL ROOM EXTENSION AND REPAIRING WORK AT 33/11 KV. SUB-STATION CHAMANGANJ, KESCo, KANPUR
Painting or varnishing on previously painted old wood or iron work iron work in small areas with two coat of approved superior quality ready mix paint "Luxol" or equivalent brand or varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should conform to the I.S. 103-1950 (OLD CSI No. 13.02+13.03)
CONTROL ROOM EXTENSION AND OTHER MISC. CIVIL WORKS AT 33/11 KV. SUB-STATION K-BLOCK KIDWAI NAGAR, KESCo KANPUR.
Painting or varnishing on previously painted old wood or iron work iron work in small areas with two coat of approved superior quality ready mix paint "Luxol" or equivalent brand or varnish including supply of all materials, labour and T&P etc. required for proper completion of the work. Paint to be used should conform to the I.S. 103-1950 (OLD CSI No. 13.02+13.03)
Repair & Development works for Hangarahalli Primary Health Center in Holenrasipura Taluk at Hassan District
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manuf...
REPAIR AND MAINTENANCE TO VARIOUS TYPE OF PRINTER TABLE NOTICE BOARD CHAIRS BED PLYWOOD TABLES SOFA MISC FURNITURE AND POLISHING OF WOODEN FURNITURE AND REPAIR OF CHARPOY AT AGE INDEPENDENT R AND D HALDWANI
(ix) All as per item No 60 (i) unsv/broken with pushing handle nut/bolt with washer complete all as specifed and directed. NOTES:- (i) Painting/Polishing work shall be carried out all around on the complete exposed suraface including internal parts like shelves, drawers, stiffners, partions etc, with spray painting process. (ii) Newly reaplced parts shall be traeted with one coat of primer before Painting/Polishing work and cost of the same deemed included in the rate of these items. (iii) Cost of removing of all dent and correcting of deshaped profiles shall deemed to be included in the unit rate of these items. (iv) Surface and site shall be made neat and clean by the contractor. (v) Contractor has to visit at site before quopting tender, Tenders may be noted that amount of creadit will be deducted from the amount arived, at the time of Acceptance of contract. (vi) Work Shall be carried out within the areas of AGE (I) R&D Haldwani, DIBER Haldwani or in the furniture yard of BSO as Specified and directed. (vii) Repairs will be carried out in furniture yard an different locations fall under AGE (I) R&D Haldwani. (viii) Duration of the contract : - 06 months.
.
) Chipping, cleaning and painting of all equipment’s & machinery Centrifugal station (all C/F Machine, Pug mill , Magma mixture, gutters etc.) during off season 2026. b) Chipping, cleaning and painting in drier house i.e. hoppers, grader, all sugar elevators, Sugar bins, power built machines, bag closure Stitching machines, conveyor chains etc.
Construction Work of Non-Residential Buildings in the Sadar Tehsil of District Shahjahanpur
Supply, installation, testing and commissioning of following capacity(160 KVA) (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural Air Natural] copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better),Dielectric material shall be type -A, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with +12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 40 dg.°C for oil and 45 dg.°C for winding up to 200 KVA and 45 dg.°C for oil and 50 dg.°C for winding for above 200 KVA. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 dg.°C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap. h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. 160 KVA