Loading…
Loading…
3,552 results • Best match
Pre-printed Thermal Paper UTS Ticket Rolls for ATVM, with 500 tickets per roll.
Description :Pre-printed Thermal Paper UTS Ticket Rolls for ATVM, with 500 tickets per roll. The size of each ticket shall be 3.38 inches x 2.5 inches. The tickets shall be wound on a plastic roll holder/core having an inner core diameter of 38 +/- 1 mm and an outer diameter of 45 +/- 1 mm. The paper low s ensor diameter shall be 48 +/- 0.5 mm. The complete details and technical specifications shall be as per Annexure-A and Annexure-B attached herewith. The parameters of UTS tickets are specified in Rail way Board Circular No. 12/2018, and the ticket drawing is specified in Railway Board Circular No. 55/2 018. ] DIVISION STORES DEPOT AJMER, Rajasthan 20470.00 In Thousand Numbers NWR DIVISION STORES DEPOT Rajasthan 24250.00 In Thousand Numbers BIKANER, NWR Consignee DIVISION STORES DEPOT Rajasthan 40182.00 In Thousand Numbers JAIPUR, NWR DIVISION STORES DEPOT Rajasthan 22281.00 In Thousand Numbers JODHPUR, NWR Inspection Stage Inspection Not Required Details
ceruch
PLASTIC CHAIR Specification attached
SUPPLY OF VARIOUS SPARE PARTS FOR VEHICLE AND MOTOR CYCLE TO THE OFFICE OF THE UNDERSIGNED
Acclerator Paddle Rubber for Hero/Hero-Honda/TVS/Bullet
Supply of Stationery Office Consumables and General Office
Supply and delivery of Gems Clip Plastic conforming to required specifications quality standards and bid conditions
SUPPLY OF FLOOR MOUNTED DIRECT RADIOGRAPHY SYSTEM WITH DUAL DETECTOR FOR HOSPITAL NIUM BENGALURU UND Floor Mounted Direct Radiography System with Dual Detector:- 1.Generator The Generator should be high frequency capacity of 30 KW or more. KV range should be 40 KV- 125 KV or more. The output at 80 KV should be 400 mA or more. Generator frequency should be 200khz or more 2. X-Ray Tube and Collimator The X-Ray Tube should be of rotating anode with dual focus having the following sizes: (i) Large focus: 1.5 mm or less. (ii) Small focus: 0.6 mm or less The unit should have Anode Heat Storage capacity of 100 KHU or more. Distance measuring scale should be provided. Should have an multi-leaf collimator having bright light source auto shut provision for the light along with automatic image cropping facility. The light output should be minimum 160lux Tube rotation on vertical axis should be - 180 degree locked (Clockwise) & + 120 degree (anticlockwise) at least with end stopper. The tube column should be ceiling-free floor mounted and should have longitudinal travel of a minimum 1500mm. Touch screen display on Tube head to control Kvp & Mas as well as selection of body parts. 3. Vertical Detector Stand The unit should be provided with vertical stand. The unit should have provision to do all upright X-Rays. The vertical Detector should travel from at least 1.4 ft to 5.5 ft above floor level. It should be flat vertical motion can be locked in any position. 4. Table The table top should be floating with transverse and longitudinal movements 250
including two batteries Detector must have inbuilt of 2 Lithium Ion Polymer batteries. The Detector should be wireless and should have operative batteries time of minimum 12 Hrs or more. Detector should have point load capacity of minimum 180 kg or more Detector should have surface load capacity of minimum 350 kg or more The Detector should work on wireless mode. Panel IPX Rating should be IP67 or better Operating temperature between 0° to 40 ° C or better. Image Acqusition time should be upto 3 Sec or better. Panels manufactured in the bordering countries of India should not be offered. 7. Detector for Table The size of detector should be minimum 43cm*43cm or more The detector should be flat panel type with A-Si ( amorphous silicon) and CSi as scintillator The detector should have a minimum storage of images. The pixel pitch should be at least 140 microns or better. It should have automatic exposure detection system It should have the Grey Scale of 16 bits or more The resolution should be minimum of 3.3 lines pair millimeter or more Active Image pixel matrix 3.0K x 3.0 K or more The Detector should have a DQE of 70% or more at 0 lp/mm Weight of detector should not be more than 3.9Kgs
WEST BS
U foam Rubber foam 40 density 6 feet X 3feet X1 inch