Loading…
Loading…
2,356 results • Best match
Color: Black
Description :R/M paint Synthetic enamel, exterior, finishing, color: Black for Railway coaches, conforming to IS:8662/2024 (Third Revision) and RDSO Am endment No. 1 (Revision. 0) for pigment content as an additional requirement to IS: 8662/2024 with additional requirements of ICF/MD/SPEC.-045 Issue St atus: 02. Rev. No.-03 dt. 14/06/2007. [ Warranty Period: 12 Months after the date of delivery ] ] AMM (ELS)BL, WR Gujarat 454.00 Litre AMM EMU MX, WR Maharashtra 15151.00 Litre AMM(W)BVP, WR Gujarat 38540.00 Litre AMM-G MAHALAXMI, WR Maharashtra 2503.00 Litre COACHING STORES DEPOT DADN, WR Madhya Pradesh 701.00 Litre Consignee DY CMM - DAHOD, WR Gujarat 8753.00 Litre DY.CMM (C) L-PAREL, WR Maharashtra 28046.00 Litre DyCMM (GS) SBI, WR Gujarat 16735.00 Litre SMM (ELS) BRCY, WR Gujarat 210.00 Litre SMM(C&W)PRTN, WR Gujarat 33500.00 Litre Inspection Details Stage Inspection Not Required
Comprehensive Annual Maintenance Contract (AMC) for 12 Nos. (Major) Integrated Power Supply Systems (IPS) (Make: Statcon Energiaa Pvt. Ltd.) over Bilaspur Division by OEM / Authorised Dealer of M/s Statcon Energiaa Pvt. Ltd. for a period of 36 Months (03 Years) on a single tender basis.
Testing, checking, and maintenance of the Month Integrated Power supply system, Major (Statcon Energiaa Make), completely consisting of the following:- a) SMR Panel, SMPS Modules, Changeover Devices & their fuses, diodes, regulators, connections, wiring & other discrete components. b) AC Distribution Panel, Inverters, Transformers, CVTs, Changeover Devices, connecting fuses, regulators, diodes, wiring and other components. c) DC Distribution Panel, DC-DC Converters, connecting filters, regulators, diodes, MOVs and other components. d) ASM Indication Panel; its Buzzers, Push Buttons and Indications. e) All Indicators, Buttons, Switches, Sockets, Buzzers, Resistances, Capacitors, Diodes, and Fuses of various ratings connected to SMR/AC/DC Panels. f) Earthing and Bonding Connections, Lightning Protection Devices (Class B/C/D). g) Maintenance of Battery Sets, Connecting Terminals/Wires, floats, etc. (Replacement to be done by Railway) = 12 Locations X 36 Months (03 Years) = 432 Months of Major IPS as per Annexure - A Total 4997579.04
SW.I- Ia) MAS-AJJ section- TTR(TWS+WCMSC)- 1 in 8.5- 2 sets. Ib)MAS-AJJ section- TTR(FS+TWS+WCMSC)- 1 in 12- 11 sets MAS AJJ section- TTR(TWS+WCMSC)- 1 in 12- 13 sets . Ic) MAS-AJJ: TTR- DS (60 kg/ PSC) 1 in 8.5.-4 sets. Id(i&ii)MAS-AJJ section- TTR ... Allied works . ...
plates shall be supplied by Railway at nearest
Execution of AT Welding of 60kg/60EI-R260 rails and 60Kg 90 UTS in-situ withsingle shot crucible and Supply of Welding portion 60kg/60EI-R260, 60kg 90UTS inconnection with sanctioned track works under jurisdiction of Divisional Engineer(Central),MMCT section(R-1).
Each 25mm gap 'in-situ' welding during traffic block and finishing of weld to meet the prescribed tolerances and pass all stipulated tests with all required labour, materials, consumables, tools, equipments etc. to complete the work in all respect as per IR's "Manual for Fusion Welding of Rails by Alumino - Thermic Process" with latest correction slips, including marking of welded joint, painting weld collar with anticorrosive paint, restoration of track near weld joint to original position and fixing of joggled fish plate at new weld, to be removed after passing of weld in USFD test as directed by Engineer in charge. Note: 1. Welding shall be carried out only by trained welder having valid competency certificate using RDSO approved Alumino Thermit Welding Portions, 3 piece prefabricated mould (ZIRCON WASHED) manually pressed, Single shot crucible fitted with auto tapping thimble and Compressed Air Petrol/LPG preheating technique as per RDSO Specification No IRST/19-2020 with latest amendment. 2. Hydraulic Weld trimmer shall be used for chipping and profile Grinder for finishing. 3. Only required nos. of Joggled fish plates shall be supplied by Railway at nearest P. Way Stores and the same shall be returned at nearest P. Way Store or at other location as per direction of Engineer-in-Charge after release from track. All other items required shall be supplied by the Contractor.
AT Welding of rail joints for 52 Kg/ 60 Kg track under Sr.DEN/S/CSMT Section.
Each 25mm gap 'in-situ' welding during traffic block and finishing of weld to meet the prescribed tolerances and pass all stipulated tests with all required labour, materials, consumables, tools, equipments etc. to complete the work in all respect as per IR's "Manual for Fusion Welding of Rails by Alumino - Thermic Process" with latest correction slips, including marking of welded joint, painting weld collar with anticorrosive paint, restoration of track near weld joint to original position and fixing of joggled fish plate at new weld, to be removed after passing of weld in USFD test as directed by Engineer in charge. Note: 1. Welding shall be carried out only by trained welder having valid competency certificate using RDSO approved Alumino Thermit Welding Portions, 3 piece prefabricated mould (ZIRCON WASHED) manually pressed, Single shot crucible fitted with auto tapping thimble and Compressed Air Petrol/LPG preheating technique as per RDSO Specification No IRST/19-2020 with latest amendment. 2. Hydraulic Weld trimmer shall be used for chipping and profile Grinder for finishing. 3. Only required nos. of Joggled fish plates shall be supplied by Railway at nearest P. Way Stores and the same shall be returned at nearest P. Way Store or at other location as per direction of Engineer-in-Charge after release from track. All other items required shall be supplied by the Contractor.
SET OF ALUMINIUM ITEMS FOR WEC COACHES OF BANGLADESH RAILWAYS.
Description :SET OF ALUMINIUM ITEMS FOR WEC COACHES OF BANGLADESH RAILWAYS. COLOUR SH ADE TO BE FOLLOWED AS PER DESIGN L. NO. MD21862 DATED 11/12/2025, as per Drawing: MPLALBL WEC VERSION 0, Packing Instruction No.PI140 VER1.0, [ Warranty Period: 30 Months after the date of delivery ] ] Consignee FURNISHING DEPOT, RCF Punjab 56.00 Set Inspection Stage Inspection Not Required Details