Construction of Block Level Stadium under Bologarh Block With Indoor hall_building
Provision of CLASS 1 +2 SPD, for power line protection, 4P ( 3PHASE + NEUTRAL), Impulse Discharge Current/POLE (10/350 s) (L - N) /(N - PE) imp,12.5 kA ( As per NBC),Numbersminal AC Voltage (50/60Hz) Uo / Un 240 V,Maximum Continuous Operating Voltage 300 V, Numbersminal Discharge Current (8/20 s) (L - N) / (N - PE) In-20KA/50 KA, Maximum Discharge Current (8/20 s) (L - N) / (N - PE) Imax -50 kA / 100 kA, Impulse Discharge Current (10/350 s) (L - N) /(N - PE) imp,12.5 kA / 50 kA, Location of Use: Main Distribution Boards Network Systems: TT, TN-S,Mode of Protection: L-N,N-PE,IEC/EN/UL Category: Class I+II / Type 1+2 / Type 1CA,Open Type 1 SPD Listed,Housing: Pluggable Design, Compliance:NBC-2016, NEC-2023,IS/IEC-62305, IEC 61643-11:2011,EN 61643-11:2012 +A11:2018,UL 1449 5th Edition . 'along with all accesories connecting cables, lugs etc(Make should be as per the approved quality and specifications. It should be approved by the user agency (Sports & YS Department) and the works should be executed as per the direction of Engineer in charge.)
Construction of Block Level Stadium under Tirtol Block With Indoor hall_building
Provision of CLASS 1 +2 SPD, for power line protection, 4P ( 3PHASE plus NEUTRAL), Impulse Discharge Current/POLE (10/350 s) (L - N) /(N - PE) imp,12.5 kA ( As per NBC),Nominal AC Voltage (50/60Hz) Uo / Un 240 V,Maximum Continuous Operating Voltage 300 V, Nominal Discharge Current (8/20 s) (L - N) / (N - PE) In-20KA/50 KA, Maximum Discharge Current (8/20 s) (L - N) / (N - PE) Imax -50 kA / 100 kA, Impulse Discharge Current (10/350 s) (L - N) /(N - PE) imp,12.5 kA / 50 kA, Location of Use: Main Distribution Boards Network Systems: TT, TN-S,Mode of Protection: L-N,N-PE,IEC/EN/UL Category: Class I+II / Type 1 plus 2 / Type 1CA,Open Type 1 SPD Listed,Housing: Pluggable Design, Compliance:NBC-2016, NEC-2023,IS/IEC-62305, IEC 61643-11:2011,EN 61643-11:2012 plus A11:2018,UL 1449 5th Edition . 'along with all accesories connecting cables, lugs etc. Make Should be as per approved quality and specifications. It should be approved by the user agency (Sports & YS Department) and the work should be executed as per direction of Engineer in charge.
Construction of Block Level Stadium under TANGI Block With Indoor hall in the district of Khordha_building
Provision of CLASS 1 +2 SPD, for power line protection, 4P ( 3PHASE + NEUTRAL), Impulse Discharge Current/POLE (10/350 s) (L - N) /(N - PE) imp,12.5 kA ( As per NBC),Numbersminal AC Voltage (50/60Hz) Uo / Un 240 V,Maximum Continuous Operating Voltage 300 V, Numbersminal Discharge Current (8/20 s) (L - N) / (N - PE) In-20KA/50 KA, Maximum Discharge Current (8/20 s) (L - N) / (N - PE) Imax -50 kA / 100 kA, Impulse Discharge Current (10/350 s) (L - N) /(N - PE) imp,12.5 kA / 50 kA, Location of Use: Main Distribution Boards Network Systems: TT, TN-S,Mode of Protection: L-N,N-PE,IEC/EN/UL Category: Class I+II / Type 1+2 / Type 1CA,Open Type 1 SPD Listed,Housing: Pluggable Design, Compliance:NBC-2016, NEC-2023,IS/IEC-62305, IEC 61643-11:2011,EN 61643-11:2012 +A11:2018,UL 1449 5th Edition . 'along with all accesories connecting cables, lugs etc(Make should be as per the approved quality and specifications. It should be approved by the user agency (Sports & YS Department) and the works should be executed as per the direction of Engineer in charge.)
Construction and Maintenance of Block level stadium under MAHAKALAPADA block (with Indoor Hall) in the district of Kendrapara_building
Provision of CLASS 1 +2 SPD, for power line protection, 4P ( 3PHASE + NEUTRAL), Impulse Discharge Current/POLE (10/350 s) (L - N) /(N - PE) imp,12.5 kA ( As per NBC),Numbersminal AC Voltage (50/60Hz) Uo / Un 240 V,Maximum Continuous Operating Voltage 300 V, Numbersminal Discharge Current (8/20 s) (L - N) / (N - PE) In-20KA/50 KA, Maximum Discharge Current (8/20 s) (L - N) / (N - PE) Imax -50 kA / 100 kA, Impulse Discharge Current (10/350 s) (L - N) /(N - PE) imp,12.5 kA / 50 kA, Location of Use: Main Distribution Boards Network Systems: TT, TN-S,Mode of Protection: L-N,N-PE,IEC/EN/UL Category: Class I+II / Type 1+2 / Type 1CA,Open Type 1 SPD Listed,Housing: Pluggable Design, Compliance:NBC-2016, NEC-2023,IS/IEC-62305, IEC 61643-11:2011,EN 61643-11:2012 +A11:2018,UL 1449 5th Edition . 'along with all accesories connecting cables, lugs etc(Make should be as per the approved quality and specifications. It should be approved by the user agency (Sports & YS Department) and the works should be executed as per the direction of Engineer in charge.)
Civil Renovation works, furnishing, Internal Electrification, MEP, Lift System, DG set, Networking, HVAC, ELV Systems, Street Lighting, Substation and connected electrics etc.
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.
Part ll Electrical Work SH- SITC of EI LAN system Access Control System CCTV Surveillance system fire Alarm System fire fighting and Sprinkler system power Backup and Elevator system therein
IP/CCTV SURVEILANCE SYSTEM SITC of 5MP (five megapixel) IR Dome Camera (2.8mm Fixed Lens) with 30 Mtr (Thirty metre) IR Distance and In-built Microphone. Image Sensor: 5 MP Dome camera 1/2.8" Progressive Scan, CMOS Sensor or Better Supported resolutions: 2593 X 1944,2592 X 1520,2048 X 1536, 1920 X 1080,720p,D1,2CIF,VGA,CIF Video Compression: H.264, H.265, MJPEG or Higher Video Standard: PAL/NTSC Number of Streaming profiles support: Profile 1: 2592 x 1944 @30fps (H.264/H.265) Profile 2: D1 @30fps (H.265/H.264) Profile 3: 2048x1536 @8fps (MJPEG) or D1/VGA@15fps(H.264/H.265) Profile 4: 1920 x 1080 @30fps (H.265/ H.264/ MJPEG) Bitrate: 128kbps-16Mbps or Better Adaptive streaming: Should Support Unicasting/ Multicasting: Support of Unicasting and Musticasting shall be provided Shutter speed: 1/15s-1/100000s or Better Minimum Illumination: Colour - 0.01 Lux @( F1.2 AGC ON) Black & white - 0 Lux or Better Signal to Noise Ratio (SNR): 70dB or better Lens focal length: 2.8 mm Lens HFOV - 107.6°, VFOV - 57.°, DFOV - 127.62° Built In IR irradiance upto: Min 30mtrs or better Zoom: 16x Digital Zoom Audio Input: IN-built Microphone Audio Output: 1 Output port Audio Compression: G.726 ,G.711 a-law and u-law Day/Night Camera Switching: Should Support Network Failure recording: In case of Network failure, the Camera shall start recording on NAS or SD Card, which can be retrived back when the network connectivity restores ( ANR) Edge Storage: 512 GB Onboard storage support or better Network Connectivity: 10Base-T/100BaseTX Ethernet (RJ-45) Supported Network Protocols: TCP/IP, UDP, HTTP, HTTPS, DHCP, DNS, DynDNS, DDNS, RTP, RTCP, RTSP, PPPOE, SMTP, NTP, SNMP, FTP, TLS/SSL, SFTP, ICMP, IGMPv2 & v3, ARP, 802.1x, IPv4, IPv6, QoS Layer 3, DSCP, CIFS, SSH, UPnP, Bonjour Data Encryption: All data, including sensitive data, is encrypted with AES and RSA IP Address Filtering: Should Support HTTPs Streaming: Should Support Edge Data Encryption: Should Support Network Authencation: 802.1x Network authentication Video Content Analytics (VCA): Detection:Motion Detection, View Tamper Detection, Trip/No Trip Detection, Object Intrusion/ Zone Intrusion IP Conflict, Network Disconnect,Storage Full, Alert Support: IP conflict, Network disconnect, storage full, time triggered, Manual Trigger. Back light Compensation (BLC): Should Support Wide Dynamic Range: 120 dB or Better Image Enhancement: Saturation,Contrast, Sharpness, Brightness, Auto Exposure, Gamma , White balance, Intelligent Defog Noise Reduction: 2 DNR, 3 DNR Power: POE (802.3af/at), 12 V 2A or Better Operating Temperature: ~30°C- +60°C or better Operating Humidity: 95% or less Ingress Protection: IP67 Impact protection: Yes, IK10 Rated Metal Housing MAC Address: The MAC address of the camera shall be registered in the name of the OEM, and it must be registered in India. ONVIF Compliance: S,G & T, The IPCamera make and model shall appear on the ONVIF Conformant products List Regulatory Approvals/ Certifications To be attach: FCC, BIS, CE , RoHs,NDAA, Cyber Security Certified by STQC to meet the essential requirement issued by MeitY IP camera & NVR: Should be same Make Plug and Play: The IPCAM shall get connected to the destined NVR/VMS when plugged in the network without adding from NVR or VMS Compliance: OEM should comply with all specifications and deviations, if any, must be clearly highlighted. Make: BOSCH/MATRIX/AXIS/INFINOVA/Securus as approved by Engineer-In-Charge including all incidentals.The rates are inclusive of octroi, royality, malkana, toll tax, sale tax, GST or other taxes imposed by the Government.