Loading…
Loading…
10,485 results • Best match
Work of laying 110 m Daya DI K-7 drinking water pipeline in a length of 575 m from Chamad Colony To Gulavthi Road Sati Mandir Chouraha
Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe ("B" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing suitably two rows of 100 mm wide PVC Tape preferabley of red colour. The M.S. pipe shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading the hole shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis). RUIDP SOR Item 4.28
Work of laying 160 m Daya DI K-7 drinking water pipeline in a length of 400 m from Dankor road Aggersen Digree Collage To BBC School.
Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe ("B" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing suitably two rows of 100 mm wide PVC Tape preferabley of red colour. The M.S. pipe shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading the hole shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis). RUIDP SOR Item 4.28
REPAIR/ REPLACEMENT OF SANITARY, FITTINGS, PLUMBING AND JOINERY WORK RIGHT SIDE OF VIKRAM BATRA ROAD UNDER AGE BR-III OF GE (N) BATHINDA AT BATHINDA MIL STN
Supply and fixing Gl frame work (snap grid framed work) for ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including hangers 6 mm dia. GI wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long at any height and position including 6-7mm thick Gypsum board with both side PVC laminated sheet, suitable for roof ceiling snap grid framed work, shape, colour and design as approved by GE including taking down of exiting false ceilimg complete all as specified and as directed.
REPAIR/ REPLACEMENT OF SANITARY, FITTINGS, PLUMBING AND JOINERY WORK LEFT SIDE OF VIKRAM BATRA ROAD UNDER AGE BR-III OF GE (N) BATHINDA AT BATHINDA MIL STN
Supply and fixing Gl frame work (snap grid framed work) for ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including hangers 6 mm dia. GI wire (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long at any height and position including 6-7mm thick Gypsum board with both side PVC laminated sheet, suitable for roof ceiling snap grid framed work, shape, colour and design as approved by GE including taking down of exiting false ceiling complete all as specified and as directed.
Road lighting work involving the installation of one 9.5-meter tubewell-style high-mast unit and four 140/150 watt lights at various locations within the city.
M & R to Various Road of Kheralu and Satlasana Section under R & B Sub Div. Visnagar (Pro. Machinery and Man power supply for During Monsoon Work-2026)
Excavation work, jungle cutting, dismantling road crust, clening water Eighteen And Paise Ninety