REPAIR/REPLACEMENT AND MAINTENANCE OF ELECTRICAL WIRING, SUB MAIN WIRING, DISTRIBUTION BOARDS AND MCBs, LIGHT FITTING/FIXTURES INCLUDING MISC ELECTRICAL WORKS AT CERTAIN OTM ACCN OF MIL STN KANCHRAPARA UNDER GE BARRACKPORE
Supply, fixing and testing of Solar street light fitting All-in-One Integrated type of 20 watts rating, LED type with solar panel of 30 watts, LED power 20 watts, Battery capacity-14AH, Lumen more than 1800 Lm, emitting colour cool white, 5700K with over charge device and backup for 08-10 hours of size 450mmx383mmx55mm complete fixed on wall/existing pole of any height ( 6M max from GL) complete all as specified and as directed.
REPAIR/REPLACEMENT AND MAINTENANCE OF ELECTRICAL WIRING, SUB MAIN WIRING, DISTRIBUTION BOARDS AND MCBs, LIGHT FITTING/FIXTURES INCLUDING MISC ELECTRICAL WORKS AT CERTAIN JCOs and ORs MD ACCN OF MIL STN KANCHRAPARA UNDER GE BARRACKPORE
Supply, fixing and testing of Solar street light fitting All-in-One Integrated type of 20 watts rating, LED type with solar panel of 30 watts, LED power 20 watts, Battery capacity-14AH, Lumen more than 1800 Lm, emitting colour cool white, 5700K with over charge device and backup for 08-10 hours of size 450mmx383mmx55mm complete fixed on wall/existing pole of any height ( 6M max from GL) complete all as specified and as directed.
WORK NO. 01 JANPAD MATHURA ME ISTHIT GOVERDHAN ME PARYTAN SUVIDHA KENDRA (DORMETRI, PARKING, CAFETAREA, TOILET BLOCK, ELECTRIC CHARGING STATION EVAM GUEST HOUSE AADI) KA NIRMAN KARYA
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 545 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.
B.C.& E.B.C Girl's Residential High School (Cap. 520) at Mahuar Bihta,Patna.
Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mountedon Aluminium/GI structure of suitable strength with following components complete as required:-a)Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/ IEC61215, IS/IEC61730-Part-1, IS/ IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% attheend of 25 years. b)Power Conditioning Unit (PCU) of 350-800V DC Input voltage range and 400V AC, three phase, 4 wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than3% and suitable for ambient temperature from 0 to 50 degreeC. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d)Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. (Make-Heron India Pvt ltd / Ojas Solar Energy/ Solar Power Tech) Note:-All Electricals & Mechanical items included.
Construction of Major Bridge over Shedhi River on Mahemdabad Nadiad Road (SH-03) at Chainage 40/350 to 41/450 (District Kheda)
Blinkers : Providing & fixing solar power road
80 MEN DOUBLE STOREY OR
Solar Light Solar Street Light 24W STORE LIST ITEMS TO BE SUPPLIED AS PER TECHNICAL SPECIFICATIONS MENTIONED IN PDF DOCUMENT