Loading…
Loading…
1,317 results • Best match
Sewerage and Septage Management for sewer system with STP and laying, jointing, testing and commissioning of Sewerage System in six (06) ULBs of Cluster-1 including 1 year defect liability with 10 years O and M.
Supply, installation, testing and commissioning of MNIE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron, showing arrangement of panel In available space and installation of PV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in ACC Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specfications, approved drawing and direction of Enginees in-charge. Note There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.
Sewerage and Septage Management for sewer system with STP and laying, jointing, testing and commissioning of Sewerage System in six (06) ULBs of Cluster-2 including 1 year defect liability with 10 years O and M.
Supply, installation, testing and commissioning of MNIE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron, showing arrangement of panel In available space and installation of PV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in ACC Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specfications, approved drawing and direction of Enginees in-charge. Note There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.
Sewerage and Septage Management for sewer system with STP and laying, jointing, testing and commissioning of Sewerage System in four (04) ULBs of Cluster-3 including 1 year defect liability with 10 years O and M.
Supply, installation, testing and commissioning of MNIE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron, showing arrangement of panel In available space and installation of PV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in ACC Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specfications, approved drawing and direction of Enginees in-charge. Note There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.
Sewerage and Septage Management for sewer system with STP and laying, jointing, testing and commissioning of Sewerage System in six (06) ULBs of Cluster-5 including 1 year defect liability with 10 years O and M.
Supply, installation, testing and commissioning of MNIE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron, showing arrangement of panel In available space and installation of PV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in ACC Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specfications, approved drawing and direction of Enginees in-charge. Note There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.
LOT-01 Modernization and Beautification Work of the Inspection House Premises at Dhukwan Weir.
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required: solar pannel 5 kw complete in all respects as per the direction and full satisfaction of the Engineer-in-Charge.
Construction of New Central Office building at Kalaburagi.
Supplying, Installing & Commissioning of Grid-connected Rooftop Solar Photo-voltaic includes of Systems Solar PV panels (with domestic cell and modules), inverter (single/3 phase wherever applicable),...