Loading…
Loading…
1,342 results • Best match
BID Document for providing and installing 150mm id Straight tubewell upto 160mtr depth with Reverse rotary rig Provision of Trial Bore Construction of OHSR 15KL Capacity having staging Height 13mtr and FSL 15mtr Prov and fixing Rising main
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. 5.00 BHPx 0.746= 3.73 3.73 x 70% = 2.61 KW Say 2.75KW(With 550watt Solar panel)
SPECIAL REPAIR OF ROAD AT AF STN WADSAR UNDER GE (AF) CHILODA
S&F in replacement solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc complete all as specified and directed.
Interception and Diversion of Nallahs with STP works Project of SARNI town under SBM 2.0 (2nd Call)
1. Design and build 3 sewage treatment plant of installed capacity 5.90,2.60 & 0.40 MLD and all appurtenant structures and allied works; 2. Construction of 1 Nos of Gravel Sand Filter of capacity 100 KLD. 3. Construction of Retaining Wall of length 100 m along the Nallah for STP. 4. Construction of 4 Nos. Interception and Diversion Structure 5. Construction of RCC sump well along with providing and installing pumps and pumping main Comprising of DI-K-7 class pipe of 150- 200 mm diameter having length of 3000 m respectively for reuse purpose. 6. Construction of RCC sump well along with providing and installing pumps and pumping main Comprising of DI-K-7 class pipe of 100 to 400 mm diameter having length of 1800 m respectively from Sump well to STP. 7. Providing, laying and jointing of NP-3 pipe of 300 mm Dia of length 100m for discharge of treated water. 8. Construction of RCC wall along the nallah of 1500 m length 9. Providing and laying of HT Feeder having length of 6.00 kms. and Electrical 1 Nos. Substation 10. On grid Solar Photo voltaic Power Plant of 200, 200 & 50 kw
Regarding Expansion of the existing RFSL building in Police Lines, Hisar
[32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate]
SPL REPAIR TO ROADS OF ATAL COLONY AND SUB DEPOT AREA AT BB CANTT, SRINAGAR IN THE AOR OF AGE B/R-II UNDER GE 864 EWS
S&F in repair of solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd manufactures instructions etc. complete all as specified and directed.
CA NO.CWE BLY/GE (W)/63 OF 2026- 2027SPECIAL REPAIRS TO ROAD INSIDE MILITARY FARM UNDER GE (WEST) BAREILLY
S&F solar cat eye aluminium alloy shall (100% water proofing design according to 65) of size 125mmx125mmx25mm shank 65mm) of high efficiency mono crystafie solar panel 2.4V/0.3 watt one Ni-ed rechargeable battery (1.2V/1600MA) conssisting of super bright LED with 10,000 to 18,000 mcd completed as per manufacturerers insturction etc all as specified and directed.