IOAOD ENGG-Development of new A site Retail Outlet BETWEEN KM STONE 2 AND KM STONE 8 WILLIAMNAGAR ON RHS PWD ROAD District East Garo Hills STATE MEGHALAYA under Guwahati Divisional office.
Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL.
IOAOD ENGG-Development of new A site Retail Outlet FROM BPCL RETAIL OUTLET M/S SOGANI MEGHALAYA SERVICE STATION UPTO MAIRANG BAZAR ON MEGHALAYA SIDE Village JIRANG District RI BHOI State MEGHALAYA under Guwahati Divisional office.
Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL.
ADDN ALTN TO BLDG NO P-11 AND P-13 AT 17 FBSU, TRIVANDRUM
M&L for overhauling & servicing the solar water heater 100 ltr capacity by removing scales from tank, painting of backup stainless steel hot water tank outer container and stands with two coat of epoxy paint over one coat of epoxy primer after cleaning foreign materials from the body all as specified and directed.
Rehabilitation, Improvement, and Basic Facilities at Dholbaha Dam, District Hoshiarpur, Punjab under Dam Rehabilitation and Improvement Project DRIP
Development of 10 KW on Grid Solar PV Power Plant i/c Solar Modules, Module Mounting Structure, Solar invertor, Wires, LA Earthing, ACDB & DCDB (Switches), Civil Works Pile Foundation, Meter & Liaoning, Structure Design.
PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR SAILORS (POS AND BELOW) AT NAVAL BASE PORBANDAR (48 DUS)
Solar Power Plant
REPAIR/MAINT TO SANITARY FITTING, PLUMBING, PLASTER, TILING, SUNKEN TREATMENT, PERIODICAL SERVICES CERTAIN B/R WORKS AND WELCOME MAINTENANCE AND REPAIR/MAINT TO ROAD AND ROAD SIDE FURNITURE AT CQA(I) RESIDENTIAL AND TECHNICAL AREA RAIPUR, DEHRADUN
S&F in repairs of solar cat eye aluminium allloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3watt one NI-ed rechargeable battery (1.2V/1600MA)consisting of super bright LED with 10000 to 18000 mcd completed as per manufactures instructions etc. all as specified and directed.