Loading…
Loading…
1,305 results • Best match
S.I.T.C of 18 Watt Solar Street Light at in District - Varanasi, Under Vidhan Mandal Kshetra Vikas Nidhi Programme.
Supply of 18 W Solar Street Light with 110 wp Solar module & 12.8 V 45 AH Lithium ferro phosphate Battery with 05 year Comprehensive warranty
Inviting Tender For Off grid solar system and submersible solar pump
Off Grid Solar System of minimum 2kva power consisting cumulative Battery capacity of minimum 400Ah, Solar panels with cumulative capacity of minimum 2000W and inverter of minimum capacity of 24volt
Installation of 4nos Solar Street Light (40W) at Sansad No VII Matikumra 128446986 (2025-26)
Installation of 4nos Solar Street Light (40W) at Sansad No VII Matikumra 128446986 (2025-26)
Design, Supply, Installation, Testing and Commissioning of Hybrid Run (Grid Solar) single stage/ Multi stage Split case/Centrifugal Pump coupled with squirrel cage Induction motor with Hybrid motor starter, SPV Panels and Rising main and its allied
Design supply testing and commissioning of Hybrid (Grid+Solar) control panel with 200Hp soft Starter Control panel with one Incomer and two out goings for two pump sets in parallel Operation. (One running and the other standby and vice versa (both on Grid + Solar) 200 HP Soft-Starter for each pump set. fixed type, floor mounted, cubical design motor control panel fabricated out of 2mm/14 SWG CRCA thick sheet duly painted, suitable for indoor use, internally wired complete with bus bar covered with PVC heat shrinkable sleeves, colour coded. Panel shall be fitted with 02 Nos. Soft Starter motor starters suitable for 3-phase, 415 Volts, 50 Hz Squirrel Cage Induction Motors, with all components of suitable rating fixed and wired in the panel. The panel shall be complete with all protections in-built (Over load/PTC/Line fault / Voltage imbalance / Phase reversal / Under voltage / Over voltage / Over temperature / Open Gate / Excessive Starts per Hr, Single phasing), Main incoming MDO ACB 300A with short circuit release including earth fault and under voltage protection. Bus bar, metering ( incoming and outgoing Voltmeter, Ampere meter, Frequency meter) (3-phase current/3-phase voltage/power factor of running motor, phase indication lamp (RYB with CTs), Outgoing ….. A ACB with 250 HP Soft starter for each pump sets, capacitor Bank 250KVAR for an improved power factor of .95 to 1, over load relays. The control panel shall be complete with single core copper cable of size 240 mm2 of 200 RMT confirming to IS 694 with required thimbles from LT transformer to Panel and 3 ½ core Al Cable of 40 RMT of current rating more than …… Ampere. Parts Catalog-01No The Soft starter component shall be at the bottom part of the panel so that the motor connection cable length is minimized.
REPAIR/REPLACEMENT OF UNSERVICEABLE STREET LIGHTS, SOLAR LIGHTS AND MAINTENANCE OF INTERNAL WIRING, LED LIGHTS AND MISC WORKS AT NAD SUNABEDA UNDER GARRISON ENGINEER (P) (NAVY) VISAKHAPATNAM
S&F in repairs 24Watt LED solar street light fitting fixed to existing pole complete all as specified and directed. (Make: CG/Surya /Bajaj / Philips / Havells)
Custom Bid for Services - Provision of Boundary Wall for New HSD Pump at DG Plant Similar Category Design, Supply, Installation, Commissioning and Maintenance of Grid Connected Roof Top Solar Power Plant Service
Commissioning and Maintenance of Grid Connected Roof Top Solar Power Plant Service