Loading…
Loading…
1,419 results • Best match
Term Contract for maintenance/ improvements and upgradation of toilets on smart toilet complex in Delhi Cantt.
Providing, Fixing, Testing, Commissioning Solar PV roof top panels system suitable for 2KWP capacity complete with all accessories, fittings, cabling, interconnection, switch overs, fan control panel and all essential and necessary ancillary fittings, fixtures, instruments, complete in all respect for trunkey operation. The rates shall include for successful functioning of Solar roof panels as per contractors design for providing specified current rating including cost of all accessories, equipments, materials, cabling, inverter etc. as approved by the Engineer-in-charge
SPL REPAIRS TO VARIOUS RD ALONGWITH CONNECTED ITEMS AT CERTAIN AREA AT MORABADI POCKET, RD, PATH, PAVER BLOCK, CULVERT AND HARDSTANDING AT NAMKUM AREA AND RD INCL REPLACEMENT OF DAMAGED CULVERTS, OTHER ASSESTS ALONGWITH ALLIED WORKS UNDER GE RANCHI
Supply and fix in Repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc., complete all as specified and directed.
SPECIAL REPAIR TO CERTAIN EM AND BR WORKS IN ELECTRIC SUPPLY INSTALLATIONS AT KANCHRAPARA MIL STN UNDER GE BARRACKPORE
Supply, erection, installing and testing of Solar LED light fittings with Extruded Aluminium Housing corrosion proof, Solar panel (Mono Crystalline Solar PV module) 60 W , LED power 24 W, Lumen/Watt > 125, Solar Charge Controller - MPPT, Battery capacity - Maintenance free Lithium Ferro Phosphate battery 12.8V - 36 Ah, BIS Approved Cells, Inbuilt BMS for Battery Safety & Enhanced battery life, Operating temperature -20 Degree to + 55 Degree, Designed for 2000 life cycle : > 5yrs life, Faster Charging, Maintenance free Backup for 2 days, PIR Motion Sensor for Automatic brightening & dimming, Lumen(LM) >3120lm, LED life time - 50000hrs, Viewing angle - 120°, Charging time - 1 day, Autonomy 2 days, CCT(K) - 5700K, Mounting height 5-6m, Working temp. -10-+55C, Dimension (mm) 1230*382*55, Net weight 18.5 Kg, including earthwork, PCC foundation as per site requirement with all accessories, cables including taking down old unserviceable solar light fitting complete all as specified and directed by E-in-C. Make: Havells- LHSTAKU7CBAF024 or equivalent in Philips/ Crompton/Wipro.
As per BOQ
M&L for solar water heater of existing capacity including checking serviceability of FPC and ETC panel choking cleaning and adding heat transfer, chemical( glycol) suitable grade with top up of suitable capacity ,replacement of defective items such evacuted tube, flat plate, nuts, washer, gasket, end bracket, insulation, reflectro of any size, complete all as specified and directed. Note: Flate plate collector and Evacuted tube collector measured and paid seprately.
Establishment Of Oil Processing Unit at Bandh Baretha Sub-Project Stage 1
Name: Solar Basic 10KW – On-Grid Solar Power Plant Description: Specs:PV Panel Make: Reputed Indian MNRE Approved Make Panel: Polycrystalline/Monocrystalline biffacial /topcon Wattage: 540-620 WP(NDCR) Inverter: Standard/Inverter type Inverter Type: On-Grid Inverter Capacity: 10 KW Structure: GI standrad ( height 6 feet)Balance of System: Included AC Cable: Polycab/Reputed – 30 meterDC Cable: Polycab/Reputed – 200 meter ACDB – 1 no IP rating IP65 or IP66 capacity 10KW,Three Phase, Voltage Rating 415V AC, Current rating 32A,UV Protected, Transparent Polycarbonate or ABS Box, AC ; MCB & surge protection device(SPD );A3 Plle ac 40ka Type 2 spd ; terminal blocks Copper Terminal Blocksfor secure AC connections, Cable Glands. All Accessories Included: Lugs, MC4 Connector etc.Earthing copper Electrode – 3 nos; Copper Bonded rods (40 mm dia, 1-2meter),Bentonite Chemical Earthing bag 10 Kg, Nut Bolt with -Washer 1 set, Ring Lug 1 No.Earthing cable– 50 meter, 6 sqmm dia ,conduction material : tinned copper ,insulation material : PVC colour : yellow / green ; spart test KV 6 (AC ) non bvreakdown , Rated temprature 70 dgree rated voltage 450/750 v , DC 1000V ,Europeon cpr : nCcca / Dca / Eca . according tot EN5057 Certificate of TUV / CE ,Construction (AWG)X B35n x mm2, conductor co instruction 494x.3n x2mm , conductor :8.8 mm Resistance max : .536 ohms/km , current carring capacity 218 A Lighthing arrestor : 1 nos , solar copper lighthing arrestor (upto 100 micron copper bonded ), solid rod with 14.2 mm diameter , dimension LXWXH 100X5X5 cm ,lighting arrestor blash plate , item weight 12 kg on GI stand METER / NET METERING -HPL /Equal STANDRAD OTHERS ;: transportation , transit insurance , 3 year warranty after 1 year from installation , 3 year annual maintence contract after 1 year fron installation , training 2 days , spare ,tool box etc ...
BUILDING AND ALLIED WORKS INCLUDING ELECTRIFICATION WORKS, HVAC, LIFT, ESCALATOR AND FIREFIGHTING WORKS ETC. IN CONNECTION WITH CONSTRUCTION OF INTERSTATE BUS TERMINAL (ISBT) AT SABROOM UNDER SOUTH TRIPURA DISTRICT.
Supplying & installation of All in one Solar Street light 40 watt (>150Lm/w,IP 66 ,LED life >50,000 hrs, 5000K,PIR,>100Wp,>36Ah) i/c necessasry connection etc as required or as per the instruction of the Engineer -in-charge:-