Loading…
Loading…
16,941 results • Best match
Procurement, Supply, Installation, Testing Commissioning of 90 Nos. Semi Integrated Solar LED Street Lights 15W each including poles, panels, batteries, wiring, civil foundation in MC Una
Procurement, Supply, Installation, Testing & Commissioning of 90 Nos. Semi-Integrated Solar LED Street Lights (15W each) including poles, panels, batteries, wiring, civil foundation, and accessories at various locations under the jurisdiction of Municipal Corporation Una. Technical Specifications Each Solar Street Light must consist of: - LED Luminaire: 15W (minimum), semi-integrated type. - Solar PV Module: 50W (minimum), poly/mono crystalline. - Battery: Li-PO4, 18Ah (minimum). - Pole: 5 mtr galvanized steel pole with mounting brackets. - Wiring: 2.5 mm², 2-core copper wiring. - Autonomy: Minimum 10–12 hrs per day with 2-day backup. - Standards: As per MNRE/HP Govt. specifications.
Construction of SuSasthya Kendra(Healthand Wellness Center) (HWC TypeB)under XV FC health grants for FY 2025-26forJalpaiIII atBoyalII under Nandigram II Block in the District of Purba MedinipurSITCof 2.2 kWp off grid Rooftop Solar PV Power plant
Design, Engineering, Installation, Testing, Commissioning & Additional 1 Year of Comprehensive Maintenance Work for Off-grid Rooftop Solar PV Power Plant (2.2 kWp) of the above said Su-Swasthya Kendra (Type-B)
REPAIR/ MAINT OF STREET/ SECURITY LIGHT FITTINGS HIGH MAST LIGHTS, SOLAR STREET LIGHT, JETTY TOWER LIGHTS, TRANSIT LIGHT AND CONNECTED WORKS AT CORE AREA, OTM ACCN INCLUDING PATANJALI, MES COMPLEX, NSRY, PIER-L, KADAMBA VANAM, MANZIL CREEK, AMB
Supply & installation outdoor panel for HML control panel housing suitable control circuit for the operation of the high mast light , made out of 3.15 mm thick CRCA sheet, double door type with sloppy canopy including suitable size of MCB TPN, contactor, digital timer and PVC connector fixed with on bus bar including wiring arrangement from panel to light fittings with suitable copper conductor cable, glands, lugs including suitable PCC (1:2;3) foundation for panel complete all as specified & directed Engr- in- Charge. NOTE:- The panel shouled be CPRI type test approved, the degree of outer shell shall be IP- 54 and should be comply IS - 8623 / 93
panels and a solar pump near the water supply well in Velhane village, Dhule taluka, Dhule district.
Installation of solar panels and a solar pump near the water supply well in Velhane village, Dhule taluka, Dhule district.
PROVN OF ROOFTOP SOLAR PLANTS (820KW) AT CERTAIN BUILDINGS UNDER GE DEOLALI
Supply, installation & Erection of suitable height as directed by engineer in charge module mounting structure with required accessories for panel mounting [Material: Hot-dip galvanized mild steel (minimum 80μm zinc coating)] suitable for 320KW roof top solar power plant . Column’s And Rafters with digging, cementing and Panel laying. (STADD PRO -180KMPH WIND), structure standard for solar panels. Structure shall be mounted using RCC/PCC blocks.MS mounting structures may be used for mounting the modules/ panels/arrays. Each structure should have angle of inclination asper the site conditions to take maximum insolation. Including structure with suitable ladder & walkway and including water pipelines, fittings, jets,valves & pump of suitable capacity with electric cableand connection complete for cleaning of solar panels with accessories. Each structure should have angle of inclination asper the site conditions to take maximum insolation. Including structure with suitable walkway MS chequered plate, 600 mm width, load capacity 150 kg/m² & Ladder: GI/MS, 450 mm width with handrails. It has to follow IS safety standards. It should include water pipelines, fittings, jets, valves & pump of suitable capacity with electric cable and connection complete for cleaning of solar panels with accessories.
Design, Supply, Installation, Testing and Commissioning of Solar rooftop work at various buildings and other requisites of Rashtriya Raksha University, Lavad Campus,Lavad, Gandhinagar
Design, Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with Solar Panels (ALMM approved): Frame Material : Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-Iron Tempered Glass (AR Coated), High efficency and positive power tolerance Pmax: 0/+5, Module Efficiency should be approx. 18%-21%, Normal operating temperature 45'C, Junction Box with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the PV module shall equal or better than -0.45%/degree C. Solar PV modules of minimum fill factor 75% to be used. Unit Production:- 4 to 5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear Power Warranty., Solar Inverter: MPPT Range: 80-1000 V, Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: 3%, Operating Tempreture Range: -25~60°C, Anti-islanding Protection: Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over Current Protection Integrated, Output Short Circuit Protection Integrated, Output Over Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: Seamless Box Pipe / 'C' Channel of suitable size for rooftop solar installations with good stability agaist wind & weight load., Hot Dipped Galvanized steel coils. suitable arrangement for base plate for foundation , solar panel mounting, the structure should be suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture should be (SS 304) quality. and Balane of System with necessary Swithgears (Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing system, lightining arrester system, all liasoning work with various gov. dipartment like state nodal agency,DISCOM & CEIG is included in agency scope. (Excluding GEDA Application fees, Solar connectivity Charges, Meter connectivity Charges, Meter testing Charges.) . Solar Panel shall be min 595Wp Each or above unit with N-Type Topcon Mono crystalline Silicon Bifacial Module with 30 years Linear Performance Warranty. (D) Grid Tied Solar Power System: 26 - 50 kW (3 - phase)