Loading…
Loading…
16,944 results • Best match
Construction of Su-Sasthya Kendra (Health and Wellness Center) (HWC Type-B) at Dalang , Jagannathpur under Keshpur Block, Paschim Medinipur, XV FC- Health grants for FY 2025-2026- SITC of 2.2 kWp off grid Rooftop Solar PV Power Plant.
Design, Engineering, Installation, Testing, Commissioning & Additional 1 Year of Comprehensive Maintenance Work for Off-grid Rooftop Solar PV Power Plant (2.2 kWp) of the above said Su-Swasthya Kendra (Type-B)
Construction of Su-Sasthya Kendra (Health and Wellness Center) (HWC Type-B) at Tabageria, Sarisakhola under Keshpur Block, Paschim Medinipur, XV FC- Health grants for FY 2025-2026- SITC of 2.2 kWp off grid Rooftop Solar PV Power Plant.
Design, Engineering, Installation, Testing, Commissioning & Additional 1 Year of Comprehensive Maintenance Work for Off-grid Rooftop Solar PV Power Plant (2.2 kWp) of the above said Su-Swasthya Kendra (Type-B)
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION CEILING FANS AND EXHAUST FANS ELECTRIC WATER HEATER DBs EARTHING LIGHT AND CONNECTED ITEMS AND REPAIR REPLACEMENT OF SOLAR WATER HEATER AND EARTHING INFRA STRUCTURE WORKS AT 39 FAD DEPOT AREA AT MIL STN
Supply and fixing in replacement of Lithium base energy efficient integrated Solar Street Light of 30/32 in aluminium Die casting body/FPR body corrosion resistance integrated PV Panel automatic dusk to input voltage 12.8V with suitable battery driver efficiency 85% PV Module itself will be used to sense the ambient light to switch ON/OFF the lamp, inbuilt MPPT charge controller, IP 65 both PIR and fixed dimming available 4500 lumens(at full brightness) with greater than 150 lumen per watt, 5700 ANSI cool white (5500K-6500K) CRI 7.0 Moptical used metal core PCB low voltage cutt offf high power LED wide beam angle (120 degree) LED Life 50000hrs weight less than 15kg with green/Red indicator with suitable battery rating 12.8V-BIS standard of complete all as specified.
Complete installation of High power Street light, Up gradation of Street Light, Installation of Solar Lightat Booth 92,96,98,99, Ward 11, Nabadwip Municipality under APAS
Installation of High Power Light (Sitanath Choudhury Lane, Ishan Saha Lane), of Booth-92, Ward no 11 within Nabadwip Municipality under APAS
Providing and Fixing 10 Nos Solar Panel Street Light from HO Dinabandhu Ray to HO Ramprosad Mondal at Mouza Shukpukuria under Dharmapukuria Gram Panchayat
Providing and Fixing 10 Nos Solar Panel Street Light from HO Dinabandhu Ray to HO Ramprosad Mondal at Sansad No XXI Mouza Shukpukuria under Dharmapukuria Gram Panchayat
REPAIR AND MAINTENANCE OF STREET LIGHT SECURITY LIGHT PERIMETER LIGHT AND SOLAR LIGHTS IN TOM ENCLAVE DEVASHISH ENCLAVE HAMID ENCLAVE AND KHULNA MARG AT SI LINES UNDER GE BHOPAL
Supply and fixing of hybrid all-in-two solar street light luminaire 70 watts with minimum 165 lm /watt system efficacy and minimum 11550 lumen. The system should consist of luminaire and Integrated solar sub-system. The solar sub system should consist of a solar panel, battery, charge controller and hybrid power supply. Solar Sub-system should be independent unit consisting of battery box with hinged cover and latches for easy maintenance and box should have prover slots for mounting of battery, charge controller and hybrid power supply. All the components should be connected with IP-66 connectors. The lithium ferrophate battery should have life class of 2000 cycles with 90% DoD and capacity should be 25.6V 48AH. System should be equipped with MPPT charge controller with AC driver. Charging efficiency should be minimum 97% and discharging efficiency should be minimum 96%. The system should be with minimum 10KV surge protection. Charge controllers should have battery/panel reverse polarity protection, over voltage/under voltage protection, over temperature protection, short circuit and open circuit protection, reverse current blocking into PV module. The system should be with 190Wp36Vmpp Solar panel. Dimming profile should be easily configurable with the help of a handheld device. The luminaire should be IP66 and IK10 protected. All the components within the solar sub-system should be connected with IP67 connector. The system should comply with IEC55015, EN61000-6-3, IEC62109, IEC 61000-4-5:2017. Battery should comply to IS16046:2018, IEC52133-2: 2017.Panel should comply to IEC61215, IEC61730-1 and IEC62804 including connecting upto junction box with 2.5sqmm 3 core PVC insulated flexible copper wire. Panel and Battery should be BIS certified complete all as specified and directed. Notes for Ser item No 18 and 19 :- 1. The Bidder has to be submitted the sample with as per CA with all required Test report. 2. Test Reports required - NABL Certified LAB, certificate of OEM , LM 80 , BIS certificate of fixture and driver both. 3. IK Test report Third Party required. 4. Department will visit the factory during technical evaluation of the OEM where accredited NABL lab consist of two photo gonio meter should be there for testing the sample 5. Bidder and OEM both should have a ISO certificate. 6. OEM and the Bidder both should declare that they have never been Blacklisted / Debarred from Any Govt. Organization 7. The contractor has submitted 5 year warranty form OEM.