Loading…
Loading…
1,426 results • Best match
CONSTRUCTION OF SOLAR WATER TANK AT KATHAL BARI SSK CENTRE AND ICDS CENTRE AT PART NO.-64(SL. NO -01)
Power Conditioning unit with enclosure : Supply, transportation, installation and commissioning of Solar Power conditioning Unit consisting of following componants and features: 1) Variable frequency Drive with inbuilt MPPT, voltage range suitable for opertating pump-motor set of 1 HP to 20 HP, detail mention in Cl. 6.1. 2) Pwer input: DC source for 1HP, 2HP & 3HP. 3) Power inpu: AC/DC source or hybrid for 5HP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5 HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2. 5) Incomer: AC MCB 4 Pole 16 amp upto 5.0 HP, 25 amp for 7.5 HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2. 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/DC of Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5 HP and 7.5 HP, 40 amp for 10 HP, 63 amp for 15 to 20 HP. 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote monitoring system. 12) Should have built-in EMC filters. 13) IP 65 glands for cable in and out. 14) Min. IP 54 enclosure. For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standeards to be qualified, etc. please refer to Cl. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I) a) For 1 HP capacity Pump-motor set with DC input.
CONSTRUCTION OF SOLAR WATER TANK AT RPF MORE NEAR KALIMANDIR AT PART NO.-70(SL. NO -04)
Power Conditioning unit with enclosure : Supply, transportation, installation and commissioning of Solar Power conditioning Unit consisting of following componants and features: 1) Variable frequency Drive with inbuilt MPPT, voltage range suitable for opertating pump-motor set of 1 HP to 20 HP, detail mention in Cl. 6.1. 2) Pwer input: DC source for 1HP, 2HP & 3HP. 3) Power inpu: AC/DC source or hybrid for 5HP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5 HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2. 5) Incomer: AC MCB 4 Pole 16 amp upto 5.0 HP, 25 amp for 7.5 HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2. 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/DC of Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5 HP and 7.5 HP, 40 amp for 10 HP, 63 amp for 15 to 20 HP. 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote monitoring system. 12) Should have built-in EMC filters. 13) IP 65 glands for cable in and out. 14) Min. IP 54 enclosure. For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standeards to be qualified, etc. please refer to Cl. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I) a) For 1 HP capacity Pump-motor set with DC input.
CONSTRUCTION OF SOLAR WATER TANK AT MAJHI PARA AT PART NO.- 62(SL. NO -05)
Power Conditioning unit with enclosure : Supply, transportation, installation and commissioning of Solar Power conditioning Unit consisting of following componants and features: 1) Variable frequency Drive with inbuilt MPPT, voltage range suitable for opertating pump-motor set of 1 HP to 20 HP, detail mention in Cl. 6.1. 2) Pwer input: DC source for 1HP, 2HP & 3HP. 3) Power inpu: AC/DC source or hybrid for 5HP and above. 4) Incomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5 HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2. 5) Incomer: AC MCB 4 Pole 16 amp upto 5.0 HP, 25 amp for 7.5 HP and 10 HP, 40 amp for 15 to 20 HP as per IS/IEC 60947-2. 6) Type II DC SPD of 40 KA. 7) Type II AC SPD of 40 KA for AC/DC of Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5 HP and 7.5 HP, 40 amp for 10 HP, 63 amp for 15 to 20 HP. 9) Reverse protection diode 1600 VDC with heat sink. 10) Data Logger. 11) Remote monitoring system. 12) Should have built-in EMC filters. 13) IP 65 glands for cable in and out. 14) Min. IP 54 enclosure. For detail features, protections, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standeards to be qualified, etc. please refer to Cl. 6.1 of technical qualification. Note: AC SPD, AC MCB and Selector switch to be provided only for item no. 3(f) to 3(I) a) For 1 HP capacity Pump-motor set with DC input.
Upgradtion & Installation of solar lights with poles in Jeelanabad area in ward No 40 in kalaburagi city. (SC CATEGORY)
Solar panel 150 watts :- (Application class as per Cl. 3 of IS/IEC 61730-1 : 2004Class A, PV Module rating (in Wp):330, Efficiency for PV Modules: 14%, BIS CRS: as per IS:IS 14286 (for Crystalline Sil...
LAC-ADS- Construction of District Library building Kozhikode- Final stage works.- Finishing work, Compound wall,Paver block laying and painting work etc-Electrification- General Electrical Work
OD23143/2026-2027:Supply, fixing, testing & commisioning of 36W(+/-2) All in One Solar street light with not less than 6000 Lumens light output and more than 160 Lumens per watt system efficiency. 50,000 burning hours as per L70. Built in maintenance free Lithium Ferro Phosphate Battery(Life Po4) with >308Wh capacity, 12v 60w solar panel module with ultra sonic sensor. The housing shall be made of CRCA Housing in non corrosive 500 hours NSS Salt spray tested finish and UV stabilised polycarbonate cover with lens for each LED's. MPPT Charge controller and driver efficency shall be greater than 90%. Equivalent to Philips BRP111 LED60/ kesslec /Osram and must have fied on existing octagonal pole
CONSULTANCY SERVICES FOR PREPARATION OF DETAILED PROJECT REPORT (DPR) FOR EXECUTION OF OTHER THAN OPERATIONAL WORKS AT MINICOY UT OF LAKSHADWEEP
(vi) Detailed external services design and layouts (a) External electric supply (b) Solar power Generation (c) External water supply (d) Road path (e) Area drainage (f) Sewage disposal (g) Fencing (h) Special Services such as Fire fighting and external fire hydrant, central AC plant, cooling & heating appliances etc. (j) Arboriculture (k) Wind energy (l) Street lights (m) Lightning protection (vii) Detail estimates (viii) Preparation of tender documents