As per BoQ
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR ., LED Street Light fixture with Minimum lumen output 15000 lm
SPL REPAIR / REPLACEMENT OF STREET LIGHTS AND ALLIED INFRA AT ZONE-III UNDER GE(SOUTH) JAIPUR AT MIL STN JAIPUR
S&F in repair LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with motion sensor based driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and directed. Note :- (i) T&P (Tools and Plant) required such as ladder, crane vehicle, manpower etc. shall be inclusive with qouted rate. (ii) The rate of necessary arrangement for fixing LED light on existing bracket like reducer or extention of pipe of suitable size as per dia of GI pipe LED light by welding etc. are inclusive in the rate.
SITC and O and M of CCMS for Street Lighting on (i) Pipli-Bhavnagar section (L 33.303 km) (ii) Bhavnagar-Talaja-Mahuva- Kagvadar-Una-Kodinar-Veraval including Kodinar Bypass section of NH 8E (L 257.085 km) under PIU Bhavnagar on 5 yr Contract Basis
Supply, Installation, Testing, Commissioning, Operation & Maintenance of Centralized Control & Monitoring System (CCMS) for Street Lighting on (i) Widening of Pipli-Bhavnagar section from Ch. Km. 136+025 to 169+328 (Design Ch.km 136+000 to Ch.Km 169+308) four laning, (ii) Four laning of Bhavnagar-Talaja section of NH - 51 from km.07.090 to km.53.585 (design ch. from km 6.945 to km 54.990),(iii) Construction of left out work of Four laning of Talaja-Mahuva section of NH-8E from Km 53.585 to Km 100.100 (Design Chainage from Km 54.990 to Km 100.450),(iv) Construction of left out work of Four laning of Mahuva-Kagvadar section of NH-8E from Km 100.100 to Km 139.915 (Design Chainage from Km 100.450 to Km 140.470),(v) Four laning of Kagvadar-Una Section of NH 8E from km 139.915 to km 180.478 (Design Chainage from Km 140.470 to Km 181.450),(vi) Four laning of the Una-Kodinar section of NH-8E (new NH-51) from Km. 180.478 to Km. 221+610 (design chainage from km. 181+450 to km. 222+400),(vii) Execution of Urgent Work from Km.222.400 to Km.230.000 (Kodinar Bypass) of stalled project of Four Laning of Kodinar - Veraval Section of NH-8E, (viii) Four Laning of Kodinar-Veraval Section NH-8E from Km. 230.000 to Km. 263.000 (Design chainage from Km 230.400 to Km. 263.180) under PIU, Bhavnagar on Five (05 Year Contract Basis.
Astronomical Timer for Street Light Control (Timer Controls) as per IS 9000 (Q3) (3 (3 ))
Astronomical Timer for Street Light Control (Timer Controls) as per IS 9000 (Q3) (3 (3 ))
FIXING OF STREET LIGHT ON NORTH EASTERN SIDE OF KHB LAYOUT IN CMC LIMITS MANDYA
Painting of existing street light pole after scrapping the old paint and painted with suitable colour enamel/Silver paint including coping/footing of the pole. 8 m and above street light pole. Schedul...
REPAIRS/ REPLACEMENT OF STREET LIGHT AND OTHER MISC WORK AT ASD, BSD, CSD, DSD, ESD, FSD, CBU AND PERIMETER AREA UNDER GE PULGAON
Dismantling of existing street light fittings, including disconnecting of wiring for all types and wattages of street lights/flood lights from pole or wall.Repairing and replacing unserviceable parts, re-fixing the same on pole/wall after testing, including removal of carbon from line jumpers, tightening of jumpers, and proper alignment of fittings.The work also includes attending defective street lights/security lights/flood lights/LED lights installed on electric poles, complete in all respects, as directed by the Engineer-in-Charge. Note: Spare parts and accessories such as LED drivers and other connected items shall be measured and paid separately under respective supply items. Fixing of these components is deemed to be included in this item.