Loading…
Loading…
3,837 results • Best match
Supply of Led Light
LED Light Item 3 Street Light 30 W White, 230V, 50Hz
REPAIR REPLACEMENT TO SECURITY/PERIPHERY LIGHTS AND OTHER CONNECTED WORKS AT AF DETT KARGIL AND AF STATION LEH UNDER GE AF LEH
Labour only for checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV fittings, LED fitting of any type, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) (or) replecement of complete fitting either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge. NOTES FOR SCH `A’ ITEM NO 1:- (i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, internal wiring wire, gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition.
Supply and Fixing of 4X18 watt 10 No. Solar High Mast light in vidhansabha kerakat Lok sabha Machhlishar,distt-Jaunpur
Supply of Solar street lighting System with 4x18watt l.e.d.(W-LED Based), 4x110 Wp 12 V Solar Module , Battery 4x12.8v 50 AH, Li-Fe-PO4 Battery) MNRE APPROVED.with 05 years warrenty
1)Proposed interlocking of LC 155 at km. 901/6-7 between Bolda - Sirli station in PAU-AK section in Nanded Division- Electrical Arrangements. 2)Proposed interlocking of LC No. 33 between ADB-PMKT and LC 74 between BDU-Jalna stations over Nanded Division- Electrical Arrangements.
Supply of 60 W LED Street light luminarie made up of pressure die cast aluminum 30 housing with high efficiency LED as lighting source and lens with toughened glass having bottom opening separate driver compartment with IP 66 protection suitable to operate with necessary mounting accessories, clamps and hardware etc
Provision of 5m Octagonal poles with 45 W led fittings and 45 W led fittings on existing poles at various locations in Amar Colony in ward no. 146 under Central Zone.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 watt
REPAIR MAINT OF OLD VINTAGE LIGHTING INFRASTRUCTURE TIMERS JUNCTION BOX LIGHTENING PROTECTION SYSTEM AND CERTAIN MISC EM WORKS AT AFTC AND AFS JALAHALLI
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-