Loading…
Loading…
3,984 results • Best match
Electrification work of Ambedkar ST Hostel building sirohi
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current 750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.
Rate Contract for Electrical Repair and Maintenance work at RB type 1and2 Ajmer
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current 750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.
Proposed Construction of Weigh Bridge and Operator Room with 1000 MT Godown at Naudiha Bazar, Palamu, Jharkhand
Supply, fitting, fixing, commissioning and testing of Solar LED Standalone Street Light( 45W LED) with low maintenance lead acid battery for 3 day backup: A LED based solar street lighting system consisting of PV modules, electronics ,lead acid battery, and LED based luminaries all suitably mounted on a 6.0m tubular pole above ground , base plate etc as required included . The battery of 160(2x80Ah) is charged by electricty generated through the PV module panel (200 i.e 100x2 )during day time and the luminaries provides light from dusk to dawn. Specification of of solar LED Standalone street Light: Poly crystalline silicon solar panels, High lumen LED for max. efficiency with lifetime> 50,000 hrs CRI nominal 70. Pressure die cast aluminium IP66 enclosure. Controller to charge batteries & microcontroller for autonomously determination of sunrise & sunset. Specific deep discharge batteries are used to store the energy. Metal battery box to be fitted at 3.0m height.
Proposed Construction of Weigh Bridge and Operator Room with 1000 MT Godown at Kanda Khas, Nawabazar, Palamu, Jharkhand
Supply, fitting, fixing, commissioning and testing of Solar LED Standalone Street Light( 45W LED) with low maintenance lead acid battery for 3 day backup: A LED based solar street lighting system consisting of PV modules, electronics ,lead acid battery, and LED based luminaries all suitably mounted on a 6.0m tubular pole above ground , base plate etc as required included . The battery of 160(2x80Ah) is charged by electricty generated through the PV module panel (200 i.e 100x2 )during day time and the luminaries provides light from dusk to dawn. Specification of of solar LED Standalone street Light: Poly crystalline silicon solar panels, High lumen LED for max. efficiency with lifetime> 50,000 hrs CRI nominal 70. Pressure die cast aluminium IP66 enclosure. Controller to charge batteries & microcontroller for autonomously determination of sunrise & sunset. Specific deep discharge batteries are used to store the energy. Metal battery box to be fitted at 3.0m height.
Proposed Construction of Weigh Bridge and Operator Room with 1000 MT Godown at Satbarwa, Palamu, Jharkhand
Supply, fitting, fixing, commissioning and testing of Solar LED Standalone Street Light( 45W LED) with low maintenance lead acid battery for 3 day backup: A LED based solar street lighting system consisting of PV modules, electronics ,lead acid battery, and LED based luminaries all suitably mounted on a 6.0m tubular pole above ground , base plate etc as required included . The battery of 160(2x80Ah) is charged by electricty generated through the PV module panel (200 i.e 100x2 )during day time and the luminaries provides light from dusk to dawn. Specification of of solar LED Standalone street Light: Poly crystalline silicon solar panels, High lumen LED for max. efficiency with lifetime> 50,000 hrs CRI nominal 70. Pressure die cast aluminium IP66 enclosure. Controller to charge batteries & microcontroller for autonomously determination of sunrise & sunset. Specific deep discharge batteries are used to store the energy. Metal battery box to be fitted at 3.0m height.
Electrification work in PHC Building at Aasotra, Block Balotra, District Balorta
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .