Loading…
Loading…
3,986 results • Best match
Proposed Construction of Weigh Bridge and Operator Room with 1000 MT Godown at Satbarwa, Palamu, Jharkhand
Supply, fitting, fixing, commissioning and testing of Solar LED Standalone Street Light( 45W LED) with low maintenance lead acid battery for 3 day backup: A LED based solar street lighting system consisting of PV modules, electronics ,lead acid battery, and LED based luminaries all suitably mounted on a 6.0m tubular pole above ground , base plate etc as required included . The battery of 160(2x80Ah) is charged by electricty generated through the PV module panel (200 i.e 100x2 )during day time and the luminaries provides light from dusk to dawn. Specification of of solar LED Standalone street Light: Poly crystalline silicon solar panels, High lumen LED for max. efficiency with lifetime> 50,000 hrs CRI nominal 70. Pressure die cast aluminium IP66 enclosure. Controller to charge batteries & microcontroller for autonomously determination of sunrise & sunset. Specific deep discharge batteries are used to store the energy. Metal battery box to be fitted at 3.0m height.
Electrification work in PHC Building at Aasotra, Block Balotra, District Balorta
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
REBUILD- R-K-I Construction of Regulator across Bharathapuzha at Koottakkadavu in Anakkara Panchayath - Balance WorkElectrical works-General Electrical Work
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Upkeeping of entire Right of Way (ROW) excluding main carriageway of various Street Scaped Road comes under South Zone, PWD, New Delhi. (SH Civil and Electrical Work).
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver asper the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMCAs per CISPR -15, lenses for beam angle asper IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
ADEN/MYA Sub-division: Construction of OHT (Over Head Tank) of 1.00 lakh litre at Maddur (MAD) station, under ADEN/Mandya jurisdiction, including Electrical portion. Maintenance period is 6 months or one monsoon period whichever is later. (Composite tender)
Supply and fixing of 45 Watt ,230 Volt Numbers AC,50 Hz, IP66 LED street light fitting along w i t h l a m p & driver with all connected materials for proper fixing and alignment conforming to specification No.SWR /LED LIGHT FITTING(Indoor/Out door)/011-2016 dt 18.04.16
C/o Divider and centre Lighting from Ambedkar centre to cherla road in Bhadrachalam Town, Bhadradri Kothagudem District, Est Cost Rs. 115.00 Lakhs
Supply and Transporation of 120W LED Street Light Body made of high grade pressure die-cast Aluminium alloy with corroaion resistant powder coal , having protective toughened glass cover, less Glare , IP 66(Silicon gasket ensure Optical & Electrical compartments are IP 66) protected , wide operating voltage range, P.F> 0.90. System having more than 10KV inbuilt and more than 4KV external,THD15% CCT:3000-6500K as desired by the department and as per IS, CRI>80, Inbuilt Electrical Protections like Over voltage, short circuit , over load , Open circuit, miswiring, etc complete with BIS manufacturer warranty letter, LM 79 andLM 80 certificates MAKE:PHILIPS/OSRAM/CROMPTON/BAJAJ/Wipro/HAVELLS/Jaquar/Eveready/Polycab LED MAKE: PHILIPS LUMILEDS/CREE/NICHIA/OSRAM/SAMSUNG/ LG LEDs