Loading…
Loading…
3,810 results • Best match
Construction of Stadium Complex at Dr.APJAKMGSSS Ground at Chetlat Island under MPLAD Scheme (18 th Lok Sabha, Lakshadweep)
Supplying and erecting waterproof LED street light/flood light fittings with High power White LED,s wattage of 250 Watt and above assembled on single MCPCB,efficiency more than 130 m/w and corrosion free high pressure die cast aluminium housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and polycarbonate optics/lenses with company mark/name engrave or embosees 120 to 300 V power Factor morethan0.95,THD10% CCT 5000 K uniformity ration >0.45,Luminaire efficiency >85 CREE/OSRAM/Philips Lumileds /NICHIA/ SEOUL/ Bridge Lux (USA) make LED used for luminaire (Each fittings requred LM 79 M& LM 80 certificates) (A) Street light (IP-65).Surge-4KV(e) above 48 to 60Watt
Additional works of New Urban Primary Health Centre Building at KVR Nagar in Ward No 42.
supply and fixing of 30W LED Street Light Fitting with LED (Lower end) with 19mm dia. GI pipe (class B) with 1 no.19mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
Development work for Tribal Destination at Mangarh Dham district Banswara (Rajasthan)
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .LED Street Light fixture with Minimum lumen output 17500 lm
As per TD
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Execution of Rural Water Supply Scheme RWSS1 for 11 MH and 48 Dhanies 12 villages and its Operation and Maintenance for 10 years after completion of 1 year DLP under CM budget announcement 2024_25 Block Kumbhalgarh District Rajsamand
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
SPL REPAIR TO SWIMMING POOL AT RSJIC UNDER GE EAST DELHI CANTT-10
S & F 35W High efficient LED Street Light Fitting with pressure die cast Aluminium Housing and Has lenses specially designed for street light with polycarbonate cover . System level efficacy og the Luminaire should more than 100lm/W. The color temperature is around 6500k with a color rendring index of 70. The luminares is IP:66 Protected . it has an electronicdriver complaint to IEC safety standards with a power factor> 0.9, voltage variation range 120-270V, THD20%, High and Low protection along with a surge protection of 4 KV including provision of 32mm dia GI light grade pipe 1.2 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed system, complete all as specified and directed.