Loading…
Loading…
3,736 results • Best match
Request for Proposal (RfP) for Design, Engineering, Procurement and Construction of a Sanitary Landfill Facility (SLF) at Morbi including Comprehensive Operation & Maintenance for a Period of 6 Years
Supply, Installation, testing and commissioning of approved make of LED Street light luminaire with die cast
REPAIR/RENEWAL TO ROOF SHEET, FALSE CEILING, WIND TIE, E/M POLES, CABLES AND ALLIED WORKS DUE TO STROM DAMAGE AT KALIMPONG MILITARY STATION UNDER GE 867 EWS
S &F street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 10 kV complete all as specified and directed by Engr in charge.
Construction /Redevelopment of Infrastructure at Kibithoo BOP of 25th Battalion ITBP, Tezu (Arunachal Pradesh), including ORs Accommodation, Cook House, Recreation Hall, Coy Office with OPs Room and WT Station, MI Room, Clothing/Ration/Miscellaneous
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). (a) 45 watt
Provision of NGOs Transit Facility (NGO TF) at Varuna Complex, NPOL, Kochi
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-32,P.F.≥0.95,IP-66,IK-10,CRI ≥70,under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
SPL REPAIR TO SWT AT SITE P AFS UNDER GE AF THANE
Supply and fixing LED Street light fitting of 90 watt, 230 v AC IP-66, ,complete all as specified and as directed by Engr-in-charge.
Electrical Items of multiple types
Led Street light The detailed specifications and eligiblity criteria are mentioned in the Additional Terms and Condition ATC document Bidders are requested to refer the ATC document