Loading…
Loading…
883 results • Best match
SPL REPAIR TO LT UG CABLE AND ASSOCIATED WORKS AT OTM ACCN AT AF STN DINJAN AND UPGRADATION OF EXISTING OLD PIPE LINE INTO PPR PIPE LINE AND CONNECTED ITEMS AT OFFICER COLONY OF ASC BN UNDER GE (AF) MOHANBARI
Supply, install, testing and commissioning of LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54, double door type with bottom cable entry with suitable cable glands structure made out of 3.15 mm (outer) & 2.00 mm (inner) thick CRCA steel sheet of minimum size (1.0x0.8 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- (Locaton- Post-4,,Post-10,) INCOMER :- (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 100 Amps with fixed thermal and fixed magnetic setting- 01 No BUSBAR :- (i) Aluminium bus bar 200 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 Nos INDICATING DEVICES :- (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos. (b) Supply and fixing Digital Ampere Meter of 0-200 A, 3 phase, class 1 with selector switch including CT having CTR 105/5 - 01 No (c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1 with selector switch- 01 No OUT GOING :- (a) Supply and fixing MCCB 3P, 40Amps, 220 Volts, C curve of breaking capacity of 10KA - 3 Nos (b) Supply and fixing Astronomical digital Timer switch along with contactor 3P 16Amps, 415V, 50Hz for street light controlling.
Spare parts compatible to existing steam generator
Opto switch inline including Fiber optic Sensor with Amplifier for probe guide tube Compatible to existing SG Manipulator system ManPOS220
SUPPLY,INSTALLATION, TESTING, COMMISSIONING AND TRAINING
CABLING SYSTEM (119A)Supply & installation of following cables with end terminations (heat shrinkable kit, cable glands with PVC shrouds, earth tag & copper lugs for Cu cables & Bimetallic lugs for Al to Cu termination, wherever applicable as per detail tender technical specifications: iv) 1.1kV, 4C x 25 sq.mm, Copper Power cables (200 m & 4 nos. end terminations); v) 1.1kV, 4C x 10 sq.mm, Copper Power cables (500 m & 10 nos. end terminations); vi) 1.1kV, 4C x 6 sq.mm, Copper Power cables (250 m & 14 nos. end terminations); vii) 1.1kV, 4C x 4 sq.mm, Copper power cables (200 m & 4 nos. end terminations); viii) 4C x 2.5 sq.mm, Copper Power cables (200 m & 16 nos. end terminations); ix) 1.1kV, 3.5C x 35 sq.mm, Copper Power cables (100 m & 4 nos. end terminations); x) 1.1kV, 3.5C x 25 sq.mm, Copper Power cables (100 m & 4 nos. end terminations); xi) 1.1kV, 3C x 6 sq.mm, Copper Power cables (1000 m & 52 nos. end terminations); xii) 1.1kV, 3C x 4 sq.mm, Copper Power cables (600 m & 16 nos. end terminations); xiii) 1.1kV, 3C x 2.5 sq.mm, Copper Power cables (150 m & 8 nos. end terminations); xiv) 1.1kV, 2C x 25 sq.mm, Copper Power cables (100 m & 6 nos. end terminations); xv) 1.1kV, 2C x 10 sq.mm, Copper Power cables (100 m & 10 nos. end terminations); xvi) 1.1kV, 2C x 6 sq.mm, Copper Power cables (600 m & 8 nos. end terminations); xvii) 1.1kV, 2C x 4 sq.mm, Copper Power cables (100 m & 2 nos. end terminations); xviii) 1.1kV, 2C x 2.5 sq.mm, Copper Power cables (500 m & 24 nos. end terminations); xix) 1.1kV, 1C x 25 sq.mm, Copper Power cables (150 m & 20 nos. end terminations). Reference Drg. Nos. i) IP1/119A/05070000/DWG/001/R0; ii) IP1/119A/05070000/DWG/002/R0; iii) IP1/119A/05070000/DWG/003/R0; iv) Doc. No. IP1/119A/05070000/DOC/001/R0.
Procurement of PLC spares for HPU installed in VAS1 plant
ControlLogix RM module Fiber Optic cable, 3m (2pcs)
The construction of Lecture halls at SVSU Dudhola Palwal
[29.6]Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon separator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. [Through Rate]
SITC of Discharge Measurement Sensors at Headworks Sumbal and Wangath of Power House USHP II Kangan
SITC of complete non-contact radar-based discharge monitoring station with standalone data logger, telemetry, SCADA integration, solar power backup, mounting accessories, enclosure, installation, testing & commissioning. Range: 0-30 m. The Job includes the connectivity of the Data Logger with the SCADA system at Power House Control Room through GSM/Optic Fibre.