Loading…
Loading…
899 results • Best match
Construction and Maintenance of Industrial Safety and Security etc at Bodhjungnagar Industrial Estate Tripura PACKAGE 18
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable 24 Port Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect.
CONSTRUCTION WORK OF OVERHEAD(OH) PORTION OF LILO of 132 kV NARA-BAGHRA LINE 132 KV S/S SUZRU ON TURNKEY BASIS
GST shall be paid extra (applicable at the time of supply/work) on total of Ex-Works, Packing and Forwarding, Transportation and Insurance Charges. Present rate of GST on work contract is 18%. *One set of installation hardware set shall contain all installation hardware fittings& accessories as may be required for 1 km of OPGW/Fibre Optic Approach Cable
E-TENDER FOR PROCUREMENT OF DENTAL MATERIALS (CONSUMABLES) BY THE PRINCIPAL, DR. R. AHMED DENTAL COLLEGE AND HOSPITAL, KOLKATA-700014.
Fiber Optic Post
SPL REPAIR TO LT UG CABLE AND ASSOCIATED WORKS AT OTM ACCN AT AF STN DINJAN AND UPGRADATION OF EXISTING OLD PIPE LINE INTO PPR PIPE LINE AND CONNECTED ITEMS AT OFFICER COLONY OF ASC BN UNDER GE (AF) MOHANBARI
Supply, install, testing and commissioning of LT outdoor Feeder Pillar Box AC 415 V, 50 Hz 3 Phase 4 wire, totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 54, double door type with bottom cable entry with suitable cable glands structure made out of 3.15 mm (outer) & 2.00 mm (inner) thick CRCA steel sheet of minimum size (1.0x0.8 x 0.6) m with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:- (Locaton- Post-4,,Post-10,) INCOMER :- (a) Supply and fixing MCCB 4 pole 415 Volts of breaking capacity of 25 KA of 100 Amps with fixed thermal and fixed magnetic setting- 01 No BUSBAR :- (i) Aluminium bus bar 200 Amps, supported on non hygroscopic fibres and brass screws for mounting -04 Nos INDICATING DEVICES :- (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos. (b) Supply and fixing Digital Ampere Meter of 0-200 A, 3 phase, class 1 with selector switch including CT having CTR 105/5 - 01 No (c) Supply & fixing Digital Voltmeter 0-500 Volts, 3 phase, class 1 with selector switch- 01 No OUT GOING :- (a) Supply and fixing MCCB 3P, 40Amps, 220 Volts, C curve of breaking capacity of 10KA - 3 Nos (b) Supply and fixing Astronomical digital Timer switch along with contactor 3P 16Amps, 415V, 50Hz for street light controlling.
Spare parts compatible to existing steam generator
Opto switch inline including Fiber optic Sensor with Amplifier for probe guide tube Compatible to existing SG Manipulator system ManPOS220
SUPPLY,INSTALLATION, TESTING, COMMISSIONING AND TRAINING
CABLING SYSTEM (119A)Supply & installation of following cables with end terminations (heat shrinkable kit, cable glands with PVC shrouds, earth tag & copper lugs for Cu cables & Bimetallic lugs for Al to Cu termination, wherever applicable as per detail tender technical specifications: iv) 1.1kV, 4C x 25 sq.mm, Copper Power cables (200 m & 4 nos. end terminations); v) 1.1kV, 4C x 10 sq.mm, Copper Power cables (500 m & 10 nos. end terminations); vi) 1.1kV, 4C x 6 sq.mm, Copper Power cables (250 m & 14 nos. end terminations); vii) 1.1kV, 4C x 4 sq.mm, Copper power cables (200 m & 4 nos. end terminations); viii) 4C x 2.5 sq.mm, Copper Power cables (200 m & 16 nos. end terminations); ix) 1.1kV, 3.5C x 35 sq.mm, Copper Power cables (100 m & 4 nos. end terminations); x) 1.1kV, 3.5C x 25 sq.mm, Copper Power cables (100 m & 4 nos. end terminations); xi) 1.1kV, 3C x 6 sq.mm, Copper Power cables (1000 m & 52 nos. end terminations); xii) 1.1kV, 3C x 4 sq.mm, Copper Power cables (600 m & 16 nos. end terminations); xiii) 1.1kV, 3C x 2.5 sq.mm, Copper Power cables (150 m & 8 nos. end terminations); xiv) 1.1kV, 2C x 25 sq.mm, Copper Power cables (100 m & 6 nos. end terminations); xv) 1.1kV, 2C x 10 sq.mm, Copper Power cables (100 m & 10 nos. end terminations); xvi) 1.1kV, 2C x 6 sq.mm, Copper Power cables (600 m & 8 nos. end terminations); xvii) 1.1kV, 2C x 4 sq.mm, Copper Power cables (100 m & 2 nos. end terminations); xviii) 1.1kV, 2C x 2.5 sq.mm, Copper Power cables (500 m & 24 nos. end terminations); xix) 1.1kV, 1C x 25 sq.mm, Copper Power cables (150 m & 20 nos. end terminations). Reference Drg. Nos. i) IP1/119A/05070000/DWG/001/R0; ii) IP1/119A/05070000/DWG/002/R0; iii) IP1/119A/05070000/DWG/003/R0; iv) Doc. No. IP1/119A/05070000/DOC/001/R0.