Loading…
Loading…
1,038 results • Best match
Monthly Basis Cab & Taxi Hiring Services - MUV; Hiring of Non AC base Model Pickup Van (MUV) of 1 tonne & above capacity to SSE/TrD/MALM Depot for OHE/PSI Breakdowns and Inspections for a period of 24 Months; Outstation 24*7
Monthly Basis Cab & Taxi Hiring Services - MUV; Hiring of Non AC base Model Pickup Van (MUV) of 1 tonne & above capacity to SSE/TrD/MALM Depot for OHE/PSI Breakdowns and Inspections for a period of 24 Months; Outstation 24*7
Monthly Basis Cab & Taxi Hiring Services - MUV; Guntakal Division Hiring of Non AC base Model Pickup Van (MUV) of 1 tonne & above capacity to SSE/TrD/HX Depot for OHE/PSI Breakdowns and Inspections for a period of 24 Months; Outstation 24*7
Monthly Basis Cab & Taxi Hiring Services | Billing:monthly | Amount:1637136
Monthly Basis Cab & Taxi Hiring Services - MUV; Hiring of 2 Nos of MUV Pick up Van at Guntakal for movement of section in charges Supervisors ie SSE CN TRD GTL and SSE E CN GTL on duty for inspections and power block works for a period of Twenty Four..
Monthly Basis Cab & Taxi Hiring Services - MUV; Hiring of 2 Nos of MUV Pick up Van at Guntakal for movement of section in charges Supervisors ie SSE CN TRD GTL and SSE E CN GTL on duty for inspections and power block works for a period of Twenty Four..
Supply, Erection and Commissioning of 3 No. 1000 KVA transformer at pump house No. 1,2 and 3 of Badhwana Disty.
Supply, Installation & Commissioning of 1000 KVA Transformer 11 KV/440V, Three phase Copper wound (i/c ACSR Conductor 50 Sqmm (Rabbit), GSL 85WG GI Nut & Bolts of sizes, eye screw bolt Wt. 0.483 Kg, earthing rod Wt. 6.175 Kg Gl pipe 40 mm dia 6 Mtr. Long earthing set B class, Gl strip 25x6 mm 9 Mtr. For earthing Wt. 10.80 Kg, lighting arrestor 9 KV, HT XLPE cable 3 C x95 Sq mm with TR, Termination Kit O/D 3 C x 95 Sq mm, Wooden Gutka GI channel 100x50x6 mm 2200 mm for holding fuse board, LT fuse board with bus bar & aluminum patti, plinth structure including PCC pole 11 Mtr. Long with half clamp weight 1.47 kg. HVPN Drg. No. 2380, full clamp weight 2.325 Kg HVPH Drg. No. 2349, 11 KV polymeric pin with insulator, 11 KV polymeric disc insulator wtih fitting (T&C type), stay set 8 ft. long complete with X-plate 460 nn of angle 65x65x6 mm elbow rod Wt. 13.80 Kg., stay wire 7/8 SWG, Gi channel 100x50x6 mm 2200 mm for H-pole Wt. 21.032 Kg, GI channel 50x50x6 mm 2400 mm for earth wire Wt. 10.80 Kg. Gl channel 75x40x6 mm 2200 mm for fuse unit Wt. 15.708 Kg, 100x50x5 mm 2200 mm for H-pole Wt. 21.032 Kg, 11 KV GO switch complete with handle, pipe & supporting channel with proper thumbing including construction of transformer platform, fencing & stone gravels & required safety signboards in switch yard area complete in all respect as per site condition & any other leftover items if any as per site requirement and specification approved by DHBVN Department) (All Type of Third party Inspections Charges e. Pre-Dispatch, Final Inspection, M&P, CEI inspection departmetal Inspection, etc. during any state inclusive of rate) at Badhwana 1,2 & 3PH.
Five Yearly Statutory Testing of 02 nos 150 MT Capacity Propane Mounded Bullets including NDT and Hydrotest and issuance of Complete Inspection report and Certificate as per appilcable Guidelines Rules and standard of PESO and OISD 150
Third party inspection services for statutory testing of mounded storage bullets including the scope of jobs of(i) Visual inspection of bullets (ii) Internal & External inspection (nozzles etc.) of the entire bullet surface to detect to deterioration (iii) Witnessing, guiding, supervising, interpretation and analysis of NDT as per scope of work given in schedule (iv) Witnessing and supervision of HPT & all tests (V) Preparation of detail reports containing observation, recommendation and certification as per SMPV rules & OISD 150. (Vi) Certifying Hydro test of each Mounded Bullet. An inspection engineer should be posted at site for supervision of the works all the time till the completion of work. The parties hired shall be reputed and are dealing/having past experience in inspection and certifications of hydro testing of LPG vessels. Should have PESO approval certificate in the name of certifying person as competent person for Mounded Storage vessel.
construction of Additional infrastructure at IISc campus, bengaluru Subwork/Packages: Providing inspection vehicle for EE& SM(C)-II(Bangalore), O/o SE&PD, CPWD, Bangalore
1 Providing service of Inspection vehicle for EE&SM(C)-II (Bangalore), O/o SE&PD, CPWD, Bangalore 533752 Above 2.99 549711.1848