Loading…
Loading…
14,617 results • Best match
Providing AND Laying of GI Pipe Line Fixing of Cistern Tank in Nagalakere Beside Tippu Sultan Masjid Fort in Ward No. 39 Ballari city
Providing AND Laying of GI Pipe Line Fixing of Cistern Tank in Nagalakere Beside Tippu Sultan Masjid Fort in Ward No. 39 Ballari city
Comprehensive Operation and Maintenance of Civil and Electromechanical assets such as intake wells structures, HR on NMC Canal , elevated service reservoirs (E.S.R), HGLR, sump, water treatment plant (Satun 60.00 mld and Zazam 6.00 mld ), chemical ... Head works , ... RWSS water supply ... water supply scheme ... including supply of ... potable water to ... Including supply of ... Raw Water Charges, ... of Pipes , ...
elevated service reservoirs (E.S.R), HGLR, sump, water treatment plant (Satun
Waterproofing Treatment to be carried out on internal walls and slab area of Overhead Water Tank of Boys Hostel building at NID Gandhinagar campus
IMPROVEMENT/ REPAIRS/ MAINTENANCE/OVERHAULING OF DG SETS AND ALLIED WORKS AND COMPREHENSIVE MAINT OF SEWAGE TREATMENT PLANT/SWIMMING POOL OF VARIOUS RATING ALONG WITH ACCESSORIES UNDER THE AOR OF GE DEOLALI
M&L for Fast Electrode maintenance free Chemical Earthing of Dual Pipe Technology of 3 Mtr long electrode with Outer pipe Diameter of 88 mm & inner pipe diameter 48 mm, Outer Surface of pipe shall be properly copper coated up to 250 Micron and Wall thickness of inner pipe 2.6 mm and 1.8 mm of outer pipe. The terminal for connection of 75 X 5.2 mm with two holes of 14 mm diameter. Fast Electrode is dully filled with the highly conductive material with sealing at both ends with lead terminal of 75 X 5.2 mm at top. The 88 mm Dia 3 Mtr Length Electrode should have type test report from CPRI. Type test report for Short time current of 42 kA rms for 1 Sec with initial peak of 88.2 kA. The Electrode should be tested in MSME Govt of India. The Electrode should be tested for Salt Spray Test as per BIS 117-09 for Corrosion for minimum 500hrs. Along with 2 bags of 25kgs each of Earth Enhancing Compound. The chemical compound should be tested and certified by any NABL accredited and BIS (Bureau of Indian Standards) accredited laboratory. The testing laboratory should be ISO 9001 & ISO 14001 certified. The earth enhancing compound should be tested referring to protocol IS 1350 & IEC62321/111/54/CDV. The pH value of compound should be between 7 to 8. The content of mercury (Hg) & Hex chromium should be below detection level. Make- FAST ELECTRODE or equivalent meke as approved by GE.(rate of GI strip of size 32x6mm upto 7.5 mtr length, GI protection pipe 40mm light grade & earth work deemed to be included in to rate quoted)
civil repair work, sanitary, plumbing work
Modernization of visitors toilet at science park of RSC Tirupati- (For details refer NIT- BoQ. The bill will be paid as per actual detailed measurement) (1 Works)
DEPOSIT Elamkunnappuzha Panchayath Laying 75 mm PVC Pipe at Fisherman road in ward 2 and Anganavady lane in Ward 8 Pipeline Work
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.