Loading…
Loading…
15,006 results • Best match
Waterproofing Treatment to be carried out on internal walls and slab area of Overhead Water Tank of Boys Hostel building at NID Gandhinagar campus
DEPOSIT Elamkunnappuzha Panchayath Laying 75 mm PVC Pipe at Fisherman road in ward 2 and Anganavady lane in Ward 8 Pipeline Work
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
Comprehensive Operation and Maintenance of Civil and Electromechanical assets such as intake wells structures, HR on NMC Canal , elevated service reservoirs (E.S.R), HGLR, sump, water treatment plant (Satun 60.00 mld and Zazam 6.00 mld ), chemical ... Head works , ... RWSS water supply ... water supply scheme ... including supply of ... potable water to ... Including supply of ... Raw Water Charges, ... of Pipes , ...
elevated service reservoirs (E.S.R), HGLR, sump, water treatment plant (Satun
IMPROVEMENT/ REPAIRS/ MAINTENANCE/OVERHAULING OF DG SETS AND ALLIED WORKS AND COMPREHENSIVE MAINT OF SEWAGE TREATMENT PLANT/SWIMMING POOL OF VARIOUS RATING ALONG WITH ACCESSORIES UNDER THE AOR OF GE DEOLALI
M&L for Fast Electrode maintenance free Chemical Earthing of Dual Pipe Technology of 3 Mtr long electrode with Outer pipe Diameter of 88 mm & inner pipe diameter 48 mm, Outer Surface of pipe shall be properly copper coated up to 250 Micron and Wall thickness of inner pipe 2.6 mm and 1.8 mm of outer pipe. The terminal for connection of 75 X 5.2 mm with two holes of 14 mm diameter. Fast Electrode is dully filled with the highly conductive material with sealing at both ends with lead terminal of 75 X 5.2 mm at top. The 88 mm Dia 3 Mtr Length Electrode should have type test report from CPRI. Type test report for Short time current of 42 kA rms for 1 Sec with initial peak of 88.2 kA. The Electrode should be tested in MSME Govt of India. The Electrode should be tested for Salt Spray Test as per BIS 117-09 for Corrosion for minimum 500hrs. Along with 2 bags of 25kgs each of Earth Enhancing Compound. The chemical compound should be tested and certified by any NABL accredited and BIS (Bureau of Indian Standards) accredited laboratory. The testing laboratory should be ISO 9001 & ISO 14001 certified. The earth enhancing compound should be tested referring to protocol IS 1350 & IEC62321/111/54/CDV. The pH value of compound should be between 7 to 8. The content of mercury (Hg) & Hex chromium should be below detection level. Make- FAST ELECTRODE or equivalent meke as approved by GE.(rate of GI strip of size 32x6mm upto 7.5 mtr length, GI protection pipe 40mm light grade & earth work deemed to be included in to rate quoted)
SH Laying, Jointing and Testing of G.I. Pipe of various Dia i/c Fittings/ Accessories in various locations under Section Manai (Under PDNA).
Laying jointing and testing of bevlled ended G.I. pipe (M-Class) various dia table-5 with circumfernital butt welded joints every two joints (94%) by electrical are welding thincless shall be equal to pipe wall thinckes)and testing of G.I. pipe of following dia cinfirming to ISI 1239-1990 (part-III) having wall thinckess as specfic below capable of with standing required test pressure including manufacturing and fabrication of reducers/tapers all short pieces etc. as per site requirement made from parent tubes the laying of pipe shall also providing MS flanged of required table including welding of flanges of every third pipe (6%) duly welded including nuts. complete within all leads and lifts. 150mm
Providing and Laying of PVC Pipe line and Restoration to Moolai street and Agathiswarar kovil street perungalathur in ward No.56 in zone 4 TCMC
Earth work excavation and depositing on bank initial lead of 1.00mand lift of 2m in narrow trenches for laying of pipes for water supply in the following type of soils of sand,silt or othe loose soil ,wey sand or silt not under water light black cotton soil ,sandy loam and ordinary soil etc complete as per standard specification.