Maintenance and Repair the Existing water Supply Distribution and main Pipeline at ward no 1 to 27 in Manapparai Municipality
Attending the following G.I Pipe leakage including cost of material ,Pipes from the pipe line and removal of slushy soil and baling out water and replacing the pipe line with sound pipe including jointing and cost of refilling the pipe line with water for retesting the pipe line etc., complete (including cost of sound pipe and jointing materials and earth work) and as directed by the Deptarmental Officers UPTO 1.5m Length (GI Pipe for 1.5m Length)
Replacement of Old Sewer Lines Providing and Laying of UPVC pipe and DIK pipe sewer from Gurudwara Sri Bhibhour Sahib upt NFL Rest House at Nangal Distt Ropar
Providing and fixing of 4 inch id and 6 inch id DI water supply pipeline in lieu of old rusted damaged CI water supply pipeline at Deen Dayal Upadhyay Colony Industrial Area Phase I Chandigarh and other contingent work thereto Ch to Capital Head Augm
Providing and laying S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes conforming to IS : 8329: (DSR No. 18.72)
REPLACEMENT OF PIPELINE WATER CONNECTION SLUICE VALVE REPAIR OF STAFF QUARTER and REPAIR OF EXPANSION JOINT OF WATER SUPPLY SCHEME SARINH BLOCK NAKODAR DISTT JALANDHAR UNDER 15th FC
Water Connection without Water Meter Providing proposed water connection without multijet water meter to house hold upto wall with providing laying jointing testing G.I. Pipeline 15mm i/d = 2.5 mtr (B-Class) as per CSR 28.36(A), (Above G.L.) Prov and fixing 20mm i/d PP-R pipe with specials = 3.00 mtr (Below GL) including cost of specials such as Tees, Bends., Sockets, Elbow, Peet Valve, Union, Nipple and Hook etc. cutting and threading testing in trenches in the ground and ISI 15mm i/d GM Ferrule as per IS:2692 and 3 inches i/d Clamp with C.I. Bib Cock, 15mm i/d as per IS:210 with Stainless Steel Strainer of approved make as per CSR 30.65(b)
Fixing of MS tank 270 ltrs. Capacity and providing, laying , jointing testing of HDPE pipe of 32mm dia
Excavating trenches of required width for pipes, cables, etc not exceeding 80 mm dia. including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including gettingout the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc.and disposing of surplus excavated soil as directed, within a lead of 50 m complete in all respect with in all leads and lifts as per direction of Engineer-in-Charge. (All kind of soil)
Providing and Laying of 12 inch i/d and 18inch i/d RCC Pipe NP-2, Storm Water Drain Pipeline on both side of the road from Junction 39 to Hallomajra Light Point including construction of Manhole, Road Gullies and other allied works thereto complete i
Excavating trenches by mechanical/ manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, by machinical/ manual means, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :