Loading…
Loading…
9,570 results • Best match
Augmentation of Water Supply Scheme Village Nanak Nagri in Block Phagwara, District Kapurthala (Under head NABARD XXXI/State Share/4215)
Construction One No. 25KL (25,000 Itrs) capacity having height 17.20 mtr of up to FSL & 15.50 mtr sill level from Ground level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing D.I. K-9 D/F expansion joints latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 9523 and C.I/D.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI double flanged pressure pipes DI K-9 horizontally as per IS 8329-2000 and latest Amendments duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel Providing & applying integral crystalline slurry hydrophilic in nature for water freezing management for vertical & horizontal service and swell able type water stop tape & painting of all complete shall be included in cost & P/F aluminum ladder inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil not less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. then the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 including overflow scour haudi complete in all respects. Note 1) Providing and applying integral crystalline slurry of hydrophilic in nature for water proofing management etc. (For vertical and horizontal surface) 2) Providing and applying of swellable type water stop tape etc
Dismantling and removal of Unserviceable GNFC water pipeline including bracket etc supported on bottom of girder passing through Railway Bridge(OWG) No. 502 between Ankleshwar-Bharuch station of ST-MYG section in the jurisdiction of SSE(Br ) BH of Vadodara Division of Western Railway.
Construction of UGSR, Estate Water Supply, Medical Bio-Waste Pre-Treatment Plant, Estate Sewerage and Rain Water Harvesting System in Trauma Center of Govt. Rajindra Hospital Patiala, Punjab (Under Head 4210 Capital Outlay on Medical and PH).
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
Electrification work in connection with "Khandwa - Improvement to water supply lines from filter house to RCC tank of Ghaspura colony and chidiya maidan colony and extension of WRP water supply line from PF No.5 to PF No. 1/2 and repairs to pump installation of Aabna pump house, filter house and Pump room No.01".
Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as
DAY TO DAY MAINT OF B/R NATURE RELATED COMPLAINTS LIKE DOOR REPAIR, INTERNAL WATER SUPPLY RELATED COMPLAINTS, WINDOW GLASS/ JALLIES, WATER TANK CLEANING AND OTHER ALLIED WORKS IN TECHNICAL AREA AT AFS HASI MARA
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed.
REPAIR/REPLACEMENT OF EXTERNAL WATER SUPPLY LINES (GI/HDPE) OF ZONE C AND D AT PATIALA MIL STN UNDER GE (N) PATIALA
Excavation in trenches for taking out, laying of pipes not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.