Loading…
Loading…
9,294 results • Best match
Providing and Laying 100 mm dia of DI water supply line various street in house no. 600 pocket and house no. 1100 pocket in sector - 8 in ward no. 34 Old Faridabad. (Recall)
Providing and Laying 100 mm dia of DI water supply line various street in house no. 600 pocket and house no. 1100 pocket in sector - 8 in ward no. 34 Old Faridabad. Details as per tender document (DNIT)
Operation Maintenance of CI/DI/HDPE/ UPVC/AC/GI Rising Main Distribution System for Nebadhui Duttapukur Zone-II Water Supply Scheme under Barasat Sub Division, P.H.E. Dte.
Supplying, laying, fiting, fixing and jointing of UPVC pipes onforming to IS:4985-2000 with latest revision and amendments, if any, with ecessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing elephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as pplicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good uality/approved brand solvent cement (as per IS:14182-1994 cluding cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as equired at site by adopting suitable method so as to facilate the aintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with istribution pipes etc. all complete as per drawing direction and atisfaction of the E.I.C. N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to beproduced before laying of pipe line. ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list.iii)No part payment at any stage on account of supply of materials shall be entertained. iv)Payment will be made on actual consumption of materials. v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate ofentire item. viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill. (PHED SOR 2019, P-L.3-5, It-2(ii) ) (A) Pressure Rating : Class - III Laying of pipe line including cost of pipe & fittings/specials butexcluding cost of valves.
Engagement of Special Third Party Independent Techno Financial Auditor for Techno Financial Audit SBM 2.0 under the jurisdiction of Punjab Water Supply and Sewerage Division No. 2, Patiala
PUNJAB WATER SUPPLY AND SEWERAGE BOARD, CHANDIGARH.
COMPREHENSIVE MAINTENANCE OF DRAINAGE PUMPS, HIGH/ LOW TRADE WASTE WATER PUMPS AND WATER SUPPLY COPE POINT AT PIER-1 NSRY INCLUDING CONNECTED ALLIED WORK IN TUNNEL SERVICES AT NSRY OF NAVAL BASE AREA KARWAR
S&F in repair of 100 mm NB sea water cope point assembly suitable for marine/ship connection with existing line after dismantling the old one consisting of: Horizontal pipe (MS/ DI/ HDPE with flange) of 100 mm NB. Bell mouth / funnel inlet for easy hose insertion. Gun metal / bronze / DI valve (sluice or butterfly valve) suitable for sea water. Non-return valve (NRV). Flanged joints with rubber insertion gasket, SS/HT nuts & bolts. Support structure / base plate fixing arrangement. The cope point shall be designed for quick connection of ship flexible hose and shall withstand saline water corrosion and marine environment. The cope point shall be robust, corrosion resistant, suitable for marine sea water application and capable of handling required discharge. Work includes: Dismantling of existing damaged cope point fabrication and alignment, proper horizontal installation, tightening of flange joints, leak testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Construction of 200mm x 165mm dia x 225 mtrs Deep HYDTW with extra Deep Well Hand Pump Platform installation of Submersible Motor Pump set and Water Supply arrangements with 4 x 1000 by 2 x 2000 ltrs HDPE Water Tank over Platform Pump Handset Hydrent
Supplying all materials, labours and tools and equipments for drilling 200 X 165mm dia. X 225 Mtr. bore well in all kinds of soil and rock in urban area with Installation of Extra Deep Handpump or Supplying and commissioning of submersible Motor Pump set of reputed make i.e. KSB/Kirloskar/V-guard/CRI or equivalent make with ISI marked 3.0/5.0/7.5 HP with required discharge & Head, Standred make (Ashirwad/ Suraksha/Gupta/Prince etc.) 32/40/50mm dia PVC submersible pipe 125mtr. pipe & 2.5/4.0 sq.mm size finolex ISI copper cable about 150.00mtr with Main Switch, (03 - phase) 32 Amp. & BCH make Panel board consisting voltmeter, ammeter, on/off switch HRC fuse unit and Internal Wiring arrangement with Platform/Pump House/Electric Meter (03-phase) & Connection/Water Supply arrangement with PVC Water tank with all complete job as per specification and direction of E/I. 06 Inch HYDTW + 3.0 H.P. Motor Pump with Iron Panel Box + 02 X 2000/4 X 1000 Litre Water Tank With all Fittings + Pump House+Platform. (Annexure - B, D, J, I & G)
Re TENDER O M Water Supply Schemes Demolishing of OHSR MWSS TO Trikkarippur Tank at Trikaripur near Kooleri SchoolGeneral Civil Work