Loading…
Loading…
3,485 results • Best match
DG HINGNA INDUSTRIAL AREA M and R to PWSS Hingna Industrial Area Supply of Poly Aluminium Chloride at Water Treatment plant at Hingna PWSS.
Supply of Poly Aluminium drinking water as per detailed specification stipulated in the tender text inclusive of all taxes, duties, transportation , loading/unloading etc. applicable for delivery of material at stores in Hingna Indl.. Area.. Supply of Poly Aluminium drinking water as per detailed specification stipulated in the tender text inclusive of all taxes, duties, transportation , loading/unloading etc. applicable for delivery of material at stores in Hingna Indl.. Area..
Procurement and supply of BIScertified water treatment chemicals for Urban Water Supply (UWS) Schemes, namely Alumina Ferric (Grade-IV conforming to IS 299 2012 Fifth Revision with latest amendments) and Hydrated Lime Grade-I, along with dosing of
Supply of ISI marked Allumino Ferric (Grade 4) strictly confirming to the requirements given in Table-1( Clauses 4.2, 8.3,B-2.3.1 & B-2.5.2) of ISI Fifth Revision with latest ammendment) in the form of slabs including loading, carriage at 3.0 MGD Surface water treatment Plant at Collegetilla as per stipulated schedule of supply, unloading, stacking properly etc complete as per direction of the Engineer- in Charge.
Procurement and supply of BIScertified water treatment chemicals for Urban Water Supply (UWS) Schemes, namely Alumina Ferric (Grade-IV conforming to IS 299 2012 Fifth Revision with latest amendments) and Hydrated Lime Grade-I, along with dosing of
Supply of ISI marked Allumino Ferric (Grade 4) strictly confirming to the requirements given in Table-1( Clauses 4.2, 8.3,B-2.3.1 & B-2.5.2) of ISI Fifth Revision with latest ammendment) in the form of slabs including loading, carriage at 3.0 MGD Surface water treatment Plant at Collegetilla as per stipulated schedule of supply, unloading, stacking properly etc complete as per direction of the Engineer- in Charge.
Procurement and supply of BIScertified water treatment chemicals for Urban Water Supply (UWS) Schemes, namely Alumina Ferric (Grade-IV conforming to IS 299 2012 Fifth Revision with latest amendments) and Hydrated Lime Grade-I, along with dosing of
Supply of ISI marked Allumino Ferric (Grade 4) strictly confirming to the requirements given in Table-1( Clauses 4.2, 8.3,B-2.3.1 & B-2.5.2) of ISI Fifth Revision with latest ammendment) in the form of slabs including loading, carriage at 3.0 MGD Surface water treatment Plant at Collegetilla as per stipulated schedule of supply, unloading, stacking properly etc complete as per direction of the Engineer- in Charge.
Procurement and supply of BIScertified water treatment chemicals for Urban Water Supply (UWS) Schemes, namely Alumina Ferric (Grade-IV conforming to IS 299 2012 Fifth Revision with latest amendments) and Hydrated Lime Grade-I, along with dosing of
Supply of ISI marked Allumino Ferric (Grade 4) strictly confirming to the requirements given in Table-1( Clauses 4.2, 8.3,B-2.3.1 & B-2.5.2) of ISI Fifth Revision with latest ammendment) in the form of slabs including loading, carriage at 3.0 MGD Surface water treatment Plant at Collegetilla as per stipulated schedule of supply, unloading, stacking properly etc complete as per direction of the Engineer- in Charge.
ROOF TREATMENT OF OFFICE EDC EUDC, PLATFORM, WATER SUPPLY, REPAIR OF PLASTER TOILET AND OTHER ASSOCIATED CIVIL WORKS AT MATATILA HYDEL COLONY JHANSI, DISTRICT-JHANSI.
Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work (NSI)