Loading…
Loading…
3,485 results • Best match
SUPPLY, DELIVERY, FITTING-FIXING OF VARIOUS SPARE PARTS ALONG WITH REPLACEMENT OF PERFORATED PIPELINE OF CHLORINATION SYSTEM AT WATER TREATMENT PLANT PH-V UNDER GRWW.
As per BOQ
M&L for water Proofing treatment to roof slabs by applying APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minium 3 Kg/Sqm, 3 mm thick (minimum) with minimum 75 mm side overlaps and minium 100 mm end overlaps complete all as specified and directed by Engr-In-Charge
Balance Works of the package of Design, Build of Raw Water Intake Well, Water Treatment Plant, Reservoir, Transmission Main for Indpur and Taldangra Block in Bankura including Operation and Maintenance for 2 years under package BKP 01
Planning, designing, preparation of site layout plan, construction/ other drawings/including submission of all supporting design calculations of work and approval by the Employer's Representative. The rate should be inclusive of all design and other allied works. and cost of any software that might be required to carry out the design including the following: (a) Design basis report, (b) Process and hydraulic design, HFD, plant layout drawing, general arrangement of individual units (c) Water treatment plant layout and hydraulic flow diagram (d) P&ID, Plant control and operation philosophy, (e) Selection of all the equipment/ pumping plant, design parameters, drawings and specifications of equipment as per make of supply items (f) Preparation of architectural and MEP drawings, (g) Structural designs and drawings (h) Process design etc including all associated Civil Works. The scope shall also include validation of the design & drawings already reviewed and approved by the Employer's Representative.
Providing and Laying of Sewer and Storm Water Line in Bishan Swaroop Colony including restoration of damaged Streets/Roads and construction of 3.00 MLD Sewerage Treatment Plant (CM Announcement Code No. 27802 dated 07.07.2024) Design, construction,
STP (SEWAGE TREATMENT PLANT): 3.00 MLD: Design, construction, erection, testing and commissioning of 3.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) including Electrical, Mechanical, Piping and Instrumentation work with PLC and SCADA arrangement for STP integrated with MPS and other works contingent thereto including 3 months successful trial-run and thereafter 6 Years Defect Liability-cum-Maintenance Period as per detail and specifications mentioned in DNIT along with following provisions 1.1 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED suitable size, outdoor type energy efficient lamps on each pole, 20 no. LED outdoor light with 7 m. high GI pole along road / path including all accessories, cable, wire etc complete in all respect. 1.2 Supply and fixing of 1 No. 3.65 m wide SS 304 main Gate along with1.25 m. wide wicket gate at STP to the entire satisfaction of Engineer-in-charge. (Total weight not less than 500 kg). 1.3 CC TV CAMERAS: Providing and Installing 6 CCTV Cameras (4 Cameras for STP and 2 Camera at MPS-1) within 96 hours of signing the agreement along with 120 days recording (DVR), 48 inch LED Screen, 16 Channel DVR at STP and MPS Site with connectors, cables, poles and power supply with online real-time output facility. The cameras at MPS and STP shall be synchronized at STP site complete in all respect. PTZ speed dome 360 degree 50X zoom camera, CP Plus Internet Protocol minimum 5 MP WDR, Night vision color mode, IR range up to 150 m. CCTV Cameras should be installed and commissioned before starting of the work.Make: Sony / Canon / Panasonic / Samsung 1.4 EWQMS (Effluent water quality monitoring system): Supply, Installation, Testing, Commissioning, Operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 3.00 MLD capacity STP for online (continuous) measurement of PH, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB and PHED, TUV approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents. 1.4.1 Multi-parameter measuring converter, for connecting up to 18 intelligent sensors Scope including 8 analog inputs / outputs (4 inputs and 4 outputs) (0/4-20Ma), wide- range power supply Optical COD/BOD and TSS probe with spectral processing of the UV-VIS range, for measurement in the outlet / effluent of 3.00 MLD capacity STP with integrated with automatic cleaning complete in all respect. 1.4.2 Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum) complete in all respect. 1.4.3 Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to the intelligent Sensor Net system. Cable length 100 meter (minimum) complete in all respect. 1.4.4 Data transfer to CPCB, HSPCB and PHED servers complete in all respect. 1.4.5 Providing GSM 3G, 4G modem with mobile network connectivity including network including complete in all respect. `1.5 Providing and installation of online flow measurement at inlet , outlet and byepass including suitable size flow meter complete in all respect` 1.6 Conveyance of treated effluent from cholorine contact tank to effluent collection tank through suitable size DI K9 pipe along with cost of pipe, sluice valves, specials, material and labour complete in all respect.
REPAIR / MAINT OF DG SETS, LT PANELS, AMF PANELS, SUPPLY OF DRINKING WATER TREATMENT CHEMICALS, CHLORINE DOSING SYSTEMS AND CONNECTED ITEMS UNDER GE CLEMENT TOWN
M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by department for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (v). The colour / shade will be all as approved by GE. (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
Providing waterproofing treatment of the terrace and replacement of old sanitary and water supply pipes of SIB Resdl. Bldg. No. 6 at Mahim dg. -2026-27.