Loading…
Loading…
6,768 results • Latest
AMPERE METER MOVING COIL TYPE, WITHOUT SHUNT, AMPERE METER SHOULD BE 0.75 MV SHUNT OPERATED RANGE 300-0-300 AMPERE DC, OUTER DIA 135MM INNER DIA 112 MM, FLUSH MOUNTED TYPE, SUITABLE FOR USE IN ROLLING STOCK APPLICATION, CONFIRMING TO RCF SPECIFICATION NO. EDTS-006 (REV-H) WITH CORRIGENDUM-5 & IS 1248-2003. ACCEPTED MAKE: AE, INDOTECH, YOKINS.
HRC Cylindrical fuse link 4A (Without holder), 1.2kV, Size 50&8MM for voltage control and item code F01 to F06 and place of installation in Switch Board Cabinet S1F90 to S1F96, as per RDSO specification No. RDSO/PE/SPEC/AC/0184-2015 (Rev-1) used for voltage control, confirming to RDSO spec No. RDSO/PE/SPEC/AC/0184-2015 (Rev-1) Suitable for LHB type AC Coaches (S1F90, S1F-91, S1F-93, S1F94, S1F-95, S1F-96)", Accepted Make as per Sr. No. 13 of Annexure of RDSO letter no. EL/7.1.108/MSSBC, dated 17.09.2021 or any RDSO approved make. RDSO specification No. RDSO/PE/SPEC/AC/0184-2015 (Rev-1) Accepted Make as per Sr. No. 13 of Annexure of RDSO letter no. EL/7.1.108/MSSBC, dated 17.09.2021 or any RDSO approved make. ACCEPTED MAKE- EATON, BUSSMAN, SIBA,WOHNER AND FERRAZ Only.
CONTACT , BHEL DRG. NO. 35801130007V00,ACS 2201/ A018 OR DLW DRG. NO. EL/PT/0630 ALT R4 CONFIRMING TO ITEM NO. 017
ALUMINIUM MOLDING FLAT SILKY WHITE ANODI
SINGLE POLE DC MCB 5A, 130V,1KA to RDSO SPECIFICATION NO: SPEC/E/-12/1/04 OF MARCH 1992 WITH AMMENDMENT 1 OF JUNE 1993 AND RDSO DRG NO SKEL 3700 ALT.1 DATED 05.09.94, SUITABLE FOR ICF BUILT MAINLINE EMU
INSULATION MONITORING RELAY, 415V AC, 3 PHASE, NEUTRAL ISOLATED, VOLTAGE RANGE 0-500V AC, INSULATION MEASURING RANGE 10K OHM TO 150K OHM, CONTROL SUPPLY 24- 240V AC/DC, PLACE OF INSTALLATION - S1A7, USED FOR INSULATION CONTROL OF 415V IN LHB TYPE AC COACHES, CONFIRMING TO RDSO SPECIFICATION NO. RDSO/PE/SPEC/AC-0184- 2015 (REV-1), SUITABLE FOR SWITCH BOARD CABINET OF LHB TYPE AC COACHES. ACCEPTED MAKE & CAT NO.: AS PER Sr. No. 68 OF RDSO LETTER NO. EL/7.1.108/MSSBC, DATED 17.09.2021, OR ANY OTHER RDSO APPROVED MAKE. RDSO SPECIFICATION NO. RDSO/PE/SPEC/AC-0184-2015 (REV-1) ACCEPTED MAKE & CAT NO.: AS PER Sr. No. 68 OF RDSO LETTER NO. EL/7.1.108/MSSBC, DATED 17.09.2021, OR ANY OTHER RDSO APPROVED MAKE. ACCEPTED MAKE :-CONTREL, WOKA, BENDER, ABB, SCHNEIDER, SIEMENS AND DOLD.
DISCONNECTING AND EARTHING DEVICE, 8-POLE, 2-WAY
RATCHET ASSEMBLY, SUITABLE FOR USE IN INTER VEHICULAR COUPLER OF 500A, 750V, OF LHB TYPE EOG COACHES, AS PER RCF DRAWING NO. LW 71330 ALT "A" AND CONFORMING TO RDSO SPECIFICATION NO. RDSO/PE/SPEC/AC/0177-2013 (REV.1).
Body side stanchion complete for BOXN wagon
Crawler Chain Assembly
Work including garbage collection and separation from every house (residential and commercial), road and drain cleaning, and cleaning of community sanitation premises in all the villages of Gram Panchayat BHAGWANPURA
SBM CLEANING WORKS GP SATOLAV
BLOOD BAG FOR COLLECTION AND PRESERVATIO
ERBA ENZYMATIC CREATININE SYSTEM PACK
TRIGLYCERIDE SYSTEM PACK FOR ERBA
URIC ACID SYSTEM PACK
Biomodified, silk protein & silver impregnated, soft, conformable, absorbent, polyurethene foam with super fluid handling capacity, (1 set consisting of 5 Dressing of 10cm x 10cm)
Hex head bolt M16x55 mm high tensile, grade 10.9,
Hex head bolt M16x170 high tensile
Hydroxyzine hydrochloride 25mg. Tab/Cap
Human Neutral insulin Inj. 40IU/ml.10 ml. Vial
Inj. semaglutide 1 mg solution for injection ( r-DNA origin) in prefilled pen
KIT SET OF FILTER & CHECK VALVE FOR ESCORTS MAKE LHB COACHES. (1) REPAIR KIT FOR AIR FILTER CONSISTING OF 04 ITEMS AS PER ANNEXURE-A TO ESCORTS DRAWING NO- 3EB 5655. (2) REPAIR KIT FOR CHECK VALVE ASSEMBLY CONSISTING OF 03 ITEMS AS PER ANNEXURE-B TO ESCORTS DRAWING NO.4EB 5664. Spec:RDSO/2011/CG%B704 (Rev.04)
RCC drain construction work from Gadwal house at Reliance Fresh Beawar Road to Beawar Road Chungi
Manpower Outsourcing Services - Fixed Remuneration - Admin; Multi-tasking Staff; Middle School
Construction work of New Sub Health Center Building at Naya Badiya (Block Raipur) District Beawar
Construction work of New Sub Health Center Building at Dhuwala (Block Kekri) District Ajmer
Construction work of New Sub Health Center Building at Didwada (Block Kishangarh) District Ajmer
Installation Of Decoratiove Pole From Entry Gate Jaipur Road To Ghugra Ghati
Construction work of New Sub Health Center Building at Arniya (Block Sarwar) District Ajmer
Construction work of New Sub Health Center Building at Alori (Block Sawar) District Ajmer
GTL_MEDICAL_PH.No.58035_MEDICINE_NORMAL SALINE 3000 ML BOTTLE.
Press plate for 3-phase traction motor as per SC Rly. Drg
Stationary Storage Type Electric Water Heaters (Geyser) (V3) ISIMarkedto IS2082 (Q2)
ERBA SGOT SYSTEM PACK EM 360
COOLANT PUMP I 170 380V 50 C S, T, A, B, C
development of water facility in anganwadi centers
Entry and Mid Level Desktop Computer (Q2), High End Desktop Computer (Q2) (3 (3 ))
ELITE H580 LYSE 1
Conforming To IS10322 (Part5/Section2) (V4) (Under BISScheme-II) (Q2)