Fabricated Room For Training of Cadets
Hiring of Coach For Peep Sight Weapon For Shooting
Hiring of Coach For Open Sight Weapon For Shooting
Office Celling Renovation and Floor Repair
Glass Wind Screen Clear, Pasting for Wind Screen Glass, FIP Seal Wind Glass
Battery 12V 7AH, UPS 1 KVA, Keyboard and Mouse, Keyboard and Mouse wireless, Motherboard, CPU Fan, DVD Writer, Power Cable for CPU, Printer USB Cable, Printer Head, Pressure Roller, Teflon Sleeve, Pickup Roller, OPC Drum, Cleaning Blade
Plywood for General Purpose MR-BB 3ply, Fevicol SR-998, Aluminium Sheet Hard 1.22MM, Sheet Cellular 337MM Thick 2Mx1M, Cutting Wheel 4 Inch
Customized AMC/CMC for Pre-owned Products - X-BIS Machine; Time Watch TW100100; Comprehensive Maintenance Contract (CMC); Not Applicable; No
NK100014 Ram DDR 58 16 GB, NK000451 Mother Board H81, NK000504 Printer Head, NK100024 Power Cable, NK000129 Logic Card, NK100027 Maintenance Box
Repair and Overhauling Service - FXS; Cube Telecom; Yes; Buyer Premises
Repair and Overhauling Service - Potable water purification system Reverse Osmosis or UV based; Zero B; Yes; Buyer Premises
Repair and Overhauling Service - Computer Printers; HP, Epson; Yes; Buyer Premises
Repair and Overhauling Service - Uninterruptible Power Supply (Ups) (DFM); Uniline, BPE; Yes; Buyer Premises
Acrylic Sheet Horse 4 Feet x 7 feet, Vinyle Cutting & Design Pasting of Horse, ACP Board
Supply, laying testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip 11000 volts grade, of size 120 sq mm 3 core, Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft loose soil all as specified and as directed., Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft loose soil all as specified and as directed, Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr-in-charge., Supply and lay of PCC cable cover class HV type 1 flat size 300mm 180mm 40mm complete all as specified and directed., Supply and lay for dry, clean, dirtless river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering, ML for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 90mm dia laid in trenches for cable protection complete all as spcified and directed., ML for fixing GI tubing 80mm dia light grade use for the protection of cable all as specified and directed by Engr-in-Charge., ML for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed, SF PCC cable route marker of size 900x300x70mm, embossed with HT UG cable 11kV and excavation of 40cm depth, grouted in and including PCC 1 2 4 type B 2, ML Cable jointing kit for 11 KV Earthed grade cable for outdoor termination Heat shrink 3 core XLPE size 120 sqmm 3 Core, M L Cable jointing kit for 11 KV Earthed grade cable for straight through heat shrink 3 Core XLPE cable of size 120 Sqmm, Insulation Tester (Q3)
width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed., Taking downout unserviceable GI HDPE Pipes of any descriptions laid in trenches andor fixing with WallsPoles complete all as specified and as directed., S F 50 mm High density polyethylene pipe HDPE of pressure rating 6 kgfcm fixed complete to walls ceilings or in floors etc. complete all as specified and directed., SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts, SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts, SF Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps, Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia. under Road Foot Path not exc. 10.00 mtr in a Single Length, ML Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Sectional area 10 Sqmm to 16 Sqmm 4 Core, ML Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty CrossSectional area 25 Sqmm to 50 Sqmm 3 1 by 2Core, All as per Item No. 25 above but of Nominal CrossSectional area exc. 70120 Sqmm 3 1 by2 Core and Testing complete all as specified and as directed, S F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed, S F HDPE DWC Double Walled Corrugated of Diameter 40 mm including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed., S F HDPE DWC Double Walled Corrugated of Diameter 50 mm including disconnection and connection of cable near panelOH for pipe fixing including joints, S F HDPE DWC Double Walled Corrugated of Diameter 100 mm including disconnection and near panel OH for pipe fixing, ML for earthing complete with MS galvanized plate of size 60cm 60cm 6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level, 06 sqmm to 16 sqmm, 25 sqmm to 50 sqmm, 70 sqmm to 95 sqmm, 120 sqmm to 240 sqmm, M L for mild steel n 5 cm long and of neck 5 to 10 mm complete all as specified and directed., Material and labour for Painting of outdoorindoor Feeder Pillar Boxes of MS Sheet with spray gun after scrapping old surfaces any size complete all as specified and directed, Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm x 4 mm with Circular 100 mm diameter 150 mm below ground level with PCC 136 40 mm aggregate, Dismantling existing LT panels of any type any size carefully for reuse including necessary excavation demolition of concrete disconnecting of earthing cable taking out burn out lugsMCCBs, SF Framed work as in doors or gates of angle or other section with gusset plates rails braces, M L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nuts bolts washers, ML PCC 136 type C2 using 40mm graded aggregate as in foundation for stay set Pole Panels etc including fair finish even and fir to exposed surfaces, M L PCC 124 type B1 with using 20 mm graded stone aggregate as coping of polepanel including necessary form work as required complete all as directed, M L for brick in CM 14 rendering using sub class B bricks straight or, M L for 15mm thick in cm 14 rendering on fair face of brick work finished even fair complete all as specified directed., M L for Hardcore of gauge n exc. 63 mm deposited spread and levelled in layers n exc. 15 cm thick watered and rammed to a true surface as specified and directed., SF Al Busbar rating as required Amps including making Holes for connections and colour coding as per existing busbar including taking down, SF in wiring Single core stranded copper conductor FRLS of size 16 sqmm including copper lugs at both ends complete all as specified and directed, SF in wiring Single core stranded copper conductor FRLS of size 10 sqmm including copper lugs at both ends complete all as specified and directed, Taking downdismantling of unserviceable LT panels complete all as specified and directed by EngineerinCharge, Supply commissioning and testing Outdoor type LT Distribution Panel Double door type IP 54 protection installed on concrete base made of PCC 136 20mm graded aggregate, Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved IP 54 protection installed on concrete base made of PCC 136, Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof 3.15mm thick sheet including IP 54 IP 54 protection installed on concrete base made of PCC 136, Insulation Tester (Q3)
Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip 1100 volts grade of size 10 sq mm 4 core, Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip 1100 volts grade of size 16 sq mm 4 core, Supply laying testing cable XLPE insulated screened PVC bedded galvanized steel strip 1100 volts grade of size 70 sq mm 3.5 core, Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in softloose soil all as specified and as directed., Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated softloose soil all as specified and as directed., Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engrincharge., ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness, ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, ML for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 40mm dia laid in trenches, ML for fixing GI tubing 40mm dia light grade use for the protection of cable all as specified and directed by EngrinCharge., ML for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed., Supply commissioning and 0 Outdoor type LT Distribution Panel Double door RIP 54136 type C1 using 20mm, ML for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs, Insulation Tester (Q3)
S and F for fibre reinforced plastic smooth white weather resistant with anti UV 30 feet long Roman pillar min dia 4 x 4 ft incl insignia of Indian Army and Corps HQ with lighting, Supply only mettalic body Air circulator 600 mm sweep pedastal 230 volt single phase 1440 RPM minimum air delivery 125 cmm 90 degree oscillotion, Surface dressing n.exc Not exceeding 15 cm deep and getting out softloose soil complete all as spd and directed., Excavation in trenches not exc 1.5m wide and not exc 1.5m deep 10 Sqm on plan and n.exc 1.5m in depth soil complete all as specified and directed., ML for Kankar or mix of fly ash clinke 1 3 6 i.e. 10 fly ash30 clinker 60 stone dust laying in layers n.exc 100mm complete all as directed by Enggincharge ., ML for broken stone or boulders hard core gauge n.exc 63mm deposited spred and levelled in layers n.exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed, ML for PCC 1 8 type D2 using 40mm graded stone aggregates as in bed concrete for foundation filling mass concrete complete all as specified and directed, M L for reinforced cement concrete Design Mix M25 20mm graded stone aggregate bases for columns etc. concrete etc complete all as directed., M L for reinforced cement concrete Design Mix M25 20mm graded stone aggregate in columns pillars piers etc complete all as specified and directed, M L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for complete all as specified and directed, Ditto but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders complete all as specified and directed, M L for formwork to sides of concrete foundations footings bases of columns raft and raft beams sides surfaces of concrete complete all as specified and directed, M L for formwork for rough finished surface of concrete flat surface to sides of surfaces of concrete complete all as specified and directed, ML for old size brickwork with fly ash bricks straight or curved on plan to any radius built in CM 1 6 complete all as specified and directed, Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed, Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in softloose complete all as specified and directed, SF for FRP Fiber Plastic display panel boards Size 14 7minimum 30mm50mm weather resistant with antiUVe complete all as spd and directed., SF for FRP Fiber Reinforced Plastic designer 10 ft Roman pillar with minimum dia 4060cm thick, Insulation Tester (Q3)
Jumper, ML for 32 6mm galvanised iron strip including connection from earthing in continuation to end point complete all as specified and as directed, Supply Install transformer 100KVA 110.433 kv 3 phase 50 Hz 63 mm graded aggregate deposited, Material and Labour RCC cable route indicator of size 1300 300 100 mm duly written HT CABLE in block letter duly engrave as MES and painted, Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip or wire armoured 70 sq mm 3.5 core, Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip or wire armoured heavy duty 1100 Volts grade size 16 sq mm 4 core., Supply laying and testing cable XLPE Insulated screened PVC beddedgalvanized steel strip, Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed, Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in SoftLoose Soil complete all as specified and as directed, Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed, ML Sand Cushioning dry in Trenches for protection of UG Cables 230mm Spread thick ness and consolidated punned upto 180mm thickness complete all as specified and as directed, Supplying and laying unreinforced precast concrete cable coverClass HV Type I flat size 300 mm x 180mm x40mm complete all as specified and as directed, ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed, SF Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps, SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts, Labour only for Horizontal Boring for Passing Protection Pipe up to 100mm Bore dia under Road Foot Path not exc. 10.00 mtr in a Single Length, S F 50 mm High density polyethylene pipe HDPE of pressure rating 6 kgfcm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed, Supply and fixing garden light 10WLED IP65 rated inverted pyramid tripod type LED bolland with soft 360 degree light distribution complete all as specified, SF Cable Junction Box 200X160X98mm in size made out of thermoplastic having IP 65 protection for outdoor installation fixed with 4 way bakelite cable, Supply commissioning and testing Outdoor type LT Distribution Panel Double door typeof size 1.2 1.2 0.450 m3.15 mm thick weather proof 3.15, Insulation Tester (Q3)
Supply laying testing cable XLPE heavy duty with stranded aluminium conductor 11000 volts grade of size 120 sq mm 3 core all as specified and as directed., Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in softloose soil all as specified and as directed., Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick as specified as directed, Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engrinchargeas specified as directed, Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm complete all as specified and directed, Supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm deep before laying and 15cm, ML for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 90mm dia, ML for fixing GI tubing 80mm dia light grade use for the protection of cable, ML for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed., SF PCC cable route marker of size 900x300x70mm embossed with HT UG cable 11kV and excavation of 40cm depth grouted, ML Cable jointing kit for 11 KV Earthed grade3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 Core all as specified and directed., M L Cable jointing kit for 11 KV Earthed grade3 Core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed., Insulation Tester (Q3)
cast iron base palate final taper plug bolts naliminium paint over a coat of red oxide zinc chrome primer, M and L for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle AC suitable for current rating upto 400 Amps, M and L for 11 kV 200 Amps outdoor type Horn Gap Fuse set conforming to IS 9385 PartI IS standards GI channel angle mounting structure, M and L for cross arms bracing supports clamps and back plates fabricated from structuralcold or hot and complete all as specified and as directed, M and L for pin type porcelain or polymer vitreous brown insulator of size 150mm height 150mm dia 11000 volts grade including one and one galvanized iron nut, M and L for disc type porcelain polymer insulator vitreous 145 mm height and 255 mm diameter ball and socket type suitable for 11000 volts grade, M and L for lightning arrestersurge protector 11 KV grade heavy duty single pole self supporting station expulsion type class 65 KA capacity, S and F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and M.S. clamps bolts and nuts of approved size for HT, M and L for Cement concrete in foundations filling and mass concrete type D2 1 4 8 using 40mm grade aggregate, M and L for PCC 1 3 6 type C2 using 40mm grade aggregate as in foundation for pole etc complete, M and L for PCC 1 2 4 type B1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth, M and L for Earthing complete with galvanised steel earth plate electrode 60 60cm 6mm thick buried directly in ground earth pit not less than 2.25 metres, M and L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in etc as required 32 6 mm, Dismantling concrete poles struts any size, Dismantling cross arms of M S channel or angle sections etc complete and setting aside for reuse with in 50m, Dismantling insulators LA any type any size, Insulation Tester (Q3)
Material and labour controlled by one one way switch using 4 sqmm nominal cross sectional area FRLSH cables in and including 20 mm dia switch boxes 3 mm thick, Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated size 4 sqmmTwo run of 6 sqmm cable one run of 4 sqmm cable, Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated unshethed single core Two run of 6 sqmm cable one run of 4 sqmm cable, Supply and fix epoxy powder coated sheet metal enclosure for double door Single pole and neutral 4 ways all as specified and directed by Engr-in-charge., Supply and fixed MCB SPN 40- 63 Amps C series 10kA 240 Volts and to be housed in DBs complete all as specified and directed, Supply and fixed MCB SP 6-32 Amps C series 10kA 240 Volts and to be housed in DBs all as specified and directed by Engr-in- charge, Supply and install hi wall split units indoor outdoor complete with cordless remote better indoor air quality with minimum 4 star rating and capacity 1.5 Ton, Supply and fixing of voltage stablizer for split AC of 4 KVA complete all specified and directed, Supply and fix single pole and neutral wth a two pin an earth plug and socket MCB SP 20 Amps complete all as specified and directed., Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick GI wire 4 mm dia as earth strip electrode 25 mm dia GI pipe, Insulation Tester (Q3)
ML for cable in trenches or XLPE electric LT cable with stranded aluminium for 1100 volts grade cross sectional area 16 sqmm 4core, ML for cable in trenches or passing through pipe XLPE insulated heavy duty aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 3.5 core, ML for cable in trenches or passing through pipe XLPE insulated heavy duty 1100 volts grade cross sectional area 35 sqmm 3.5 core, ML for cable in trenches or passing through pipe XLPE insulated heavy duty 1100 volts grade cross sectional area 95 sqmm 3.5 core, Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed., Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified and as directed, Removing excavated Materials Soil not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr as specified as directed, ML Sand Cushioning in Trenches for of UG Cables and in of 230mm Spread thickness and punned upto 180mm thicknesscomplete all as specified and as directed, ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable as specified as directed, SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable as pecified as directed, SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable inMild Steel Clamps Nuts Bolts as specified as directed, S F HDPE DWC Double Walled Corrugated of Diameter 40 mm as specified as directed, S F HDPE DWC Double Walled Corrugated of Diameter 63 mm with including disconnection as specified as directed, ML for Horizontal Boring for Passing Protection Pipe up to 80mm Bore under Road Foot Path not exc. 10.00 mtr in a Single Length as specified as directed, ML for earthing MS galvanized plate of size 60cmx60cmx6mm buried directly in ground earth pit not less than 2.25 mtrs deep below ground level, Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof PCC 136 type C1 using 20mm graded aggregate, Supply Fixing sheet moulding compound junction box IP 66 suitable size with knockouts for cable 2 Nos 4 x 10 to 35 Sqmm, Supply Fixing submain wiring with 4 Runs of 6 Sqmm PVC insulated unsheathed single core multi stranded 1100 volts, Supply Fixing submain wiring with 2 Runs of 6 Sqmm PVC insulated unsheathed single core 1100 volts FRLS copper conductor cable 6 sqmm, Insulation Tester (Q3)
Surface dressing n exc 15 cm deep and getting out soft loose soil complete, Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc or for shafts n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft or loose soil complete, M and L for Kankar or laterite with mix of fly ash clinker stone dust in the proportion of 1 3 6 laying in layers n exc 100mm thick watering ramming and compacted complete, M and L for broken stone or boulders hard core gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surfaces complete all as specified and directed, M and L for PCC 1 4 8 type D 2 as in bed concrete for foundation filling and mass concrete complete all as specified and directed, M and L for reinforced cement concrete Design Mix M 25 foundations including rafts footings foundation beams plinth beams bases for columns, M and L for reinforced cement concrete Design Mix M 25 20mm graded stone aggregate in columns pillars piers etc complete all as specified and directed, M and L for TMT bars 10mm dia and over cut to length bent to shape required not less than 0.9mm dia or securing with clips complets all as specified and directed, Ditto but 5mm dia and over upto and including 10mm dia in stirrups spacers and binders complete all as specified and directed, M and L for formwork to sides of concrete foundations for rough finished surfaces of concrete complete all as specified and directed, M and L for formwork for rough finished surface of concrete flat surface to sides of pillars concrete complete all as specified and directed, M and L for old size brickwork with fly ash bricks straight or curved on plan to any radius built in CM 1 6 complete all as specified and directed, Removing surplus soil to a distance not exceeding 50 mtr and directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed, Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft or loose complete all as specified and directed, S and F for FRP display panel boards Size 14 7 minimum 30mm to 50mm thickness with smooth white weather resistant with anti UV coating anchored on FRP structure, S and F for FRP designer 10 ft Roman pillar with minimum dia 40 to 60cm heavy duty anchor bolts with smooth white weather resistant with anti UV coating, S and F for FRP upper beam with MS or Iron base designed with tile matchign alongwith other connected items complete, S and F for parking stand floor mount heavy duty mild steel 20 mm dia min thickness 1.50 mm with powder coated, Insulation Tester (Q3)