Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
30 Nov 2026, 8:00 pm5d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Published by the portal on this tender, for queries and grievance redressal.
Material and labour controlled by one one way switch using 4 sqmm nominal cross sectional area FRLSH cables in and including 20 mm dia switch boxes 3 mm thick
Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated size 4 sqmmTwo run of 6 sqmm cable one run of 4 sqmm cable
Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated unshethed single core Two run of 6 sqmm cable one run of 4 sqmm cable
Supply and fix epoxy powder coated sheet metal enclosure for double door Single pole and neutral 4 ways all as specified and directed by Engr-in-charge.
Supply and fixed MCB SPN 40- 63 Amps C series 10kA 240 Volts and to be housed in DBs complete all as specified and directed
Supply and fixed MCB SP 6-32 Amps C series 10kA 240 Volts and to be housed in DBs all as specified and directed by Engr-in- charge
Supply and install hi wall split units indoor outdoor complete with cordless remote better indoor air quality with minimum 4 star rating and capacity 1.5 Ton
Supply and fixing of voltage stablizer for split AC of 4 KVA complete all specified and directed
Supply and fix single pole and neutral wth a two pin an earth plug and socket MCB SP 20 Amps complete all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick GI wire 4 mm dia as earth strip electrode 25 mm dia GI pipe
Insulation Tester (Q3)
10162120
GEM/2026/B/8270856
Two Packet Bid
Supply and fixed MCB SPN 40-63 Amps C series 10kA 240
Bardhaman, West Bengal
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
2 yrs
30%
Exempted
Yes
19 Nov 2026
19 Nov 2026
1 Dec 2026
90 days from bid end date (until 1 Mar 2027)
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | Material and labour controlled by one one way switch using 4 sqmm nominal cross sectional area FRLSH cables in and including 20 mm dia switch boxes 3 mm thick | Material and labour wiring for socket out let on independent Boards controlled by one, one way switch using 4 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia switch boxes 3 mm thick bakelite sheet top cover fitted with Chromium plated brass screws washers and 2.5 sqmm nominal cross sectioanl area PVC insulated unsheathed washers etc. complete all as specified. | 6 | Per Point | Bardhaman | 90 |
| 2 | Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated size 4 sqmmTwo run of 6 sqmm cable one run of 4 sqmm cable | Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated unshethed single core multi-stranded copper conductor of size 4 sqmm and one run of 2.5 sqmm copper conductor as continuity earth wire drawn in and including PVC Conduit concealed of suitable size but not less than 20 mm dia on wall floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring all as specified and directe Two run of 6 sqmm cable,one run of 4 sqmm cable, one run of PVC conduit shall be measured and paid as one unit. | 150 | RM | Bardhaman | 90 |
| 3 | Matetial and labour for sub-main wiring with two run of FRLSH PVC insulated unshethed single core Two run of 6 sqmm cable one run of 4 sqmm cable | Matetial and labour for sub main wiring with two run of FRLSH PVC insulated unshethed single core multi-stranded copper conductor of size 6 sqmm and one run of 4 sqmm copper conductor as continuity earth wire drawn in and including PVC Conduit concealed of suitable size but not less than 20 mm dia on wall floor etc including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring all as specified and directed Note Two run of 6 sqmm cableone run of 4 sqmm cable one run of PVC conduit shall be measured and paid as one unit. | 90 | RM | Bardhaman | 90 |
| 4 | Supply and fix epoxy powder coated sheet metal enclosure for double door Single pole and neutral 4 ways all as specified and directed by Engr-in-charge. | Supply and fix epoxy powder coated sheet metal enclosure for DBs double door Single pole and neutral 4 ways with mounting fitted with 200 Amps rated bus bar DIN channel neutral link and incoming contact complete all as specified and directed by Engr-in-charge. | 4 | Each | Bardhaman | 90 |
| 5 | Supply and fixed MCB SPN 40-63 Amps C series 10kA 240 Volts and to be housed in DBs complete all as specified and directed | Supply and fixed MCB SPN 40-63 Amps C series 10kA 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed by Engr-in-charge. | 4 | Each | Bardhaman | 90 |
| 6 | Supply and fixed MCB SP 6-32 Amps C series 10kA 240 Volts and to be housed in DBs all as specified and directed by Engr-in-charge | Supply and fixed MCB SP 6-32 Amps C series 10kA 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed by Engr-in-charge. | 8 | Each | Bardhaman | 90 |
| 7 | Supply and install hi wall split units indoor outdoor complete with cordless remote better indoor air quality with minimum 4 star rating and capacity 1.5 Ton | Supply and install hi wall split units indoor outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and capacity 1.5 Ton complete all as specified and directed by Engr-in-charge. | 6 | Each | Bardhaman | 90 |
| 8 | Supply and fixing of voltage stablizer for split AC of 4 KVA complete all specified and directed | Supply and fixing of voltage stablizer for split AC of 4 KVA including all connected items complete all specified and directed by Engr-in-charge. | 6 | Each | Bardhaman | 90 |
| 9 | Supply and fix single pole and neutral wth a two pin an earth plug and socket MCB SP 20 Amps complete all as specified and directed. | Supply and fix single pole and neutral sheet metal enclosure wth a two pin an earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and directed. | 6 | Each | Bardhaman | 90 |
| 10 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick GI wire 4 mm dia as earth strip electrode 25 mm dia GI pipe | Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode 25 mm dia GI pipe | 3 | Each Set | Bardhaman | 90 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_10162120.pdf
GEM_BID • 0.15 MB
blank_pdf_2026-11-13-11-28-49_d2b4bbb914618ec9600f3c2dc55fbf7b.pdf
BOQ • 0.17 MB
rev_57_2026-11-13-11-28-49_f0752906208360ea5e20d165a4518401.csv
BOQ • 0.01 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .