Loading…
Loading…
27 results • Latest
Monthly Basis Cab and Taxi Hiring Service - Without Fuel - SUV; Mahindra Bolero, Mahindra Scorpio; 2024; 75, 000- 1, 00, 000 kms; A/C; 24 Hrs
Fabricated Special Purpose Vehicle on Truck/Van (Q3) (3 (3 ))
GI Pipe 6 inch DIA, Carriage of 11 METER ST POLE SP55, Carriage of PCC POLE 8.5 METER, Carriage of 13 METER ST POLE SP55, Carriage of 3.5Cx240 Sq.mm LT XLPE CABLE AL, Carriage of 11 KV XLPE CABLE SIZE 3X185 SQ.MM, Carriage of 33 KV XLPE CABLE SIZE 3C300 SqMM, Carriage of CABLE LT ABC 3C120 AND 1C95 AND 1C16 SQMM, Carriage of COMPLETE STAY SET, Carriage of EARTHING OF POLE, Carriage of 11 KV PIN INSULATOR, Carriage of 11 KV PIN WITH NUT, Carriage of 11 KV DISC INSULATOR, Carriage of 11 KV DISC FITTING, Carriage of 11 KV CROSS ARM, Carriage of ACSR WEASEL CONDUCTOR, Carriage of GI WIRE 6or8 SWG, Carriage of Disc. Insulators BandS type 7000 kg, Carriage of Disc. Fittings Dog 7000 Kg, Carriage of 33 KV Pin Insulator, Carriage of 33 KV Pin with nuts, Carriage of THREE PHASE DISTRIBUTION BOX, Carriage of 33 KV V type Cross arm, Carriage of E bracket for 33 KV, Fixing of CABLE CROSSING DETAILS BOARD, Fixing work of cable in GI Pipe 6 inch DIA, Laying stringing sagging binding and jumpering ACSR WEASEL CONDUCTOR, Laying stringing sagging CABLE LT ABC size 3X120 1X95 1X16 SQMM, Mounting of Three Phase Distribution Box, Erection of single pole structure 8.5 Mtrs PCC Pole, Erection of single pole structure 11 Mtrs and 13 Mtr ST Pole, Erection of Double pole structure 11 Mtr STP Pole, Erection of TRI pole structure 11 Mtr STP Pole, Erection of Four pole structure 11 Mtr STP Pole, Grouting of PCC and STP POLE, Grouting of Stay, Earthing of pole by M S Earthing Rod, Guarding of 11 KV Line with Gaurding Angel, Laying of Cable by HDD Method 33 KV XLPE CABLE SIZE 3C300 SqMM, Laying of Cable by HDD Method 3.5CBY240 Sq.mm LT XLPE CABLE AL, Laying of Cable by HDD Method 11 KV XLPE CABLE SIZE 3X185 SQ.MM, Installation Of 11 KV CABLE JOINTING KIT SUITABLE FOR 3X185 SQMM, Installation Of 11 KV CABLE JOINTING KIT STREIGHT THROUGH 3X185 SQMM, Installation Of 33 KV Cable Outdoor Jointing, Installation Of 33 KV Cable streight through, Installation Of JOINTING KIT SUITABLE FOR 3.5C240 SQMM LT CABLE, Removal of 25 KVA Transformer and Mounting of newly constructed Double Pole, DISMENTLING AND RECEIVED BACK OF MATERIAL
Supply of 2200 Nos Jumper cones for 800kV ACSR Lapwing Conductor at Mainpuri
Fuse Set from ESC MNP, Carriage of 11 KV TPMO with Polymer Insulator from ESC MNP, Carriage of Complete Stay 9GI Stay Rod 20x1800 mm etc material from ESC MNP, Carriage of Distribution Transformer 25 KVA from ESC MNP, Carriage of Distribution Transformer 63 KVA from ESC MNP, Carriage of Distribution Transformer 100 KVA from ESC MNP, Carriage of Distribution Transformer 250 KVA from ESC MNP, Carriage of ACSR weasel Conductor from ESC MNP, Carriage of M S Earthing Rod 20 x2540 mm from ESC MNP, Carriage of LT AL. XLPE CABLE SIZE 1x240 Sq.mm. from ESC MNP, Carriage of LT XLPE CABLE 1X120 Sq.mm. FOR DTR from ESC MNP, Carriage of LT XLPE CABLE 1X400 Sq.mm. FOR DTR from ESC MNP, Carriage of LT XLPE Cable Size 3.5x70 or 35 Sq.mm. from ESC MNP, Carriage of LT AB Cable 3x120 1x95 1x16 Sq.mm. from ESC MNP, Carriage of LT AB Cable 3x50 1x35 1x16 Sq.mm. from ESC MNP, Carriage of LT AB Cable 3x95 1x70 1x16 Sq.mm. from ESC MNP, Carriage of 33 KV XLPE Cable 3x300 Sq.mm. from ESC MNP, Carriage of 33 KV Indoor or Outdoor Jointing Kit Size 3x300 Sq.mm. from ESC MNP, Carriage of 33 KV Straight Through Size 3x300 Sq.mm. from ESC MNP, Carriage of G.I. Wire 6 or 8 SWG for Guarding from ESC MNP, Carriage of Three Phase Distribution Box from ESC MNP, Erection of Fixing of LT Fuse Set Protection Box with all respective Accessories As per Norms, Execution of Chemical Earthing with G.I. Patti Clamp Nut and Bolts as per Norms, Erection of L.T. Tail Less unit with all respective material as Grouted Angel with Fabrication work etc., Laying of ACSR weasel Conductor, Laying of LT AB Cable 3x120 1x95 1x16 Sq.mm., Laying of LT AB Cable 3x50 1x35 1x16 Sq.mm., Laying of LT AB Cable 3x95 1x70 1x16 Sq.mm., Mounting of Three Phase Distribution Box, Erection of Double pole structure 8.5 Mtr PCC Pole, Erection of single pole structure 8.5 Mtrs PCC Pole, Erection of TRI pole structure 33 KV 13 Mtr ST Pole, Grouting of PCC or STP POLE, Grouting of Stay, Earthing of pole, Guarding of 11 KV Line, Fencing of 250 KVA Distribution Transformers, Plinth for 250 KVA Transformer, Installation of 11by0.4 KV TF 25 KVA, Installation of 11by0.4 KV TF 63 KVA, Installation of 11by0.4 KV TF 100 KVA, Installation of 11by0.4 KV TF 250 KVA, Laying of 33 KV XLPE Cable 3x300 Sq.mm., Installation Of 33 KV Indoor or Outdoor Jointing Kit Size 3x300 Sq.mm. As per Norms., Dismentlling, Received Back and Safe Carriage of Jarjar G.I. Wire and Weasel Conducter including with rolling from Pit Site to ESC, Mainpuri, Received Back of Distribution Transformer after Increasing Capacity from pit site to ESC