Loading…
Loading…
3,606 results • Latest
Single acting air lock Relay Make: Azbil, Single acting positioner model HTTP Make: Azbil, Pilot relay assy of double Acting Positioner Model VPP 03 Make: Azbil, Double acting positioner model VPP-03 Make: Azbil
Procurement of New Generation Cranes for different Plants
Facility Management Services - LumpSum Based - Cleaning of CHP; Cleaning of CHP; Consumables to be provided by service provider (inclusive in contract cost)
Procurement of miscellaneous electrical spares
Welding Receptacle
Customized AMC/CMC for Pre-owned Products - Non comprehensive Annual maintenance Contract services ETP online effluent quality monitoring system installed installed at Atps Anpara along with data transmission service support to CPCB and UPPCB for One..
Facility Management Services - LumpSum Based - Thermal Power Station; Housekeeping, catering & canteen; Consumables to be provided by service provider (inclusive in contract cost)
M/s Emerson make Hart Calibrator & Communicator for precise Field calibration & communication of Sma
RENOVATION AND MODERNIZATION OF OIL SUPPLY UNITS OF LPBP SYSTEM IN STAGE 1 RIHAND
RENOVATION AND MODERNIZATION OF SERVO VALVES OF HPBP SYSTEM IN STAGE 1 RIHAND
Schedule 1 - 10 - M5507286226, Schedule 2 - 20 - M5507286238
100259221 - M1010012016 - CARBON-DECHLORNATION, 50KG
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - BMD-I, 3X 210 MW ATPS ANPARA; Online Leak Sealing of HP valves of boiler and Turbine area of all the seven units of all three stages A B and D TPS of Anpara Sonebhadra; ..
HAND HELD COMMUNICATOR (FOR SMART PRESSURE TRANSMITTERS, DIFF. PRESS. TRANSMITTER, 10 TO+ 90 MBAR, FLOW TRANSMITTER, 0-1800 MBAR, PRESSURE TRANSMITTER 0-400 BAR, PRESSURE TRANSMITTER 0-80 BAR, PRESSURE TRANSMITTER 0-16 BAR, PRESSURE TRANSMITTER (-) 1 TO 399 BAR, PRESSURE TRANSMITTER (-1) TO (+ 39) BAR, PRESS. TRANSMITTER, 0-1.3BAR, ABS, 0-10BAR (ABS), PRESSURE TRANSMITTER (-1) TO (+ 3) BAR, TURBINE, PRESSURE TRANSMITTER (-1) TO (+ 9) BAR, PRESSURE RANSMITTER (- 1) TO (+ 19) BAR, PRESSURE TRANSMITTER (-) 1 TO 50 BAR, PRESSURE TRANSMITTER, 1 TO+ 79 BAR, PRESSURE TRANSMITTER (-) 1 TO (+ ) 109 BAR
Procurement of Disc of MS stop valve St 1 at NTPC RIHAND.
SCRAPER GEARED MOTOR Part no. TB2486, SCRAPER GEAR BOX Part No. - TB2206
Boiler Tube Fins and Shield
Pressure rlief valve
Custom Bid for Services - Misc. Electrical Maintenance/OH of Power Plant LT Systems/Battery and Battery Chargers/DCDB/Lighting Maintenance & Street Lighting Electrical Shift Maintenance Jobs/EOT Crane & Hoist, VFD, Fire Fighting, Hydrogen Plant, DM .. Similar Category MULTI-PROTOCOL LABEL SWITCHING SERVICE(MPLS SERVICE)
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - LT Switchgear; Electrical System or Installation; Service Provider
List of Seller Organization for participation SAPS POWER EQUIPMENTS PRIVATE LIMITED Winflex Resilient, Coupling No. 152 AEE ( 4 set ), Grid For Winflex Resilient Coupling No. 152 AEE (SPL)
Facility Management Services - LumpSum Based - Industrial; Work of Maintenance & Installation of rolling shutter infront of TG Building; Consumables to be provided by service provider (inclusive in contract cost)
LED LIGHTS
Item_10_M1618920498_100273330_Schedule 1 _ PIPE,CS,A106-B,SMLS,6.30MM,25MM, Item_20_M1618027627_100273330_Schedule 2 _ PIPE,CS,A106-C,10.15 MM,40 NB, Item_30_M1618033572_100273330_Schedule 3 _ PIPE,CS,A106- C,8.74MM,60.33MM,50MM, Item_40_M1618037617_100273330_Schedule 4 _ PIPE,CS,A106-C,SMLS,9.74MM,65MM, Item_50_M1718390606_100273330_Schedule 5 _ ELBOW,BW,CS,A234- WPC,90DEG,LR,25MM, Item_60_M1713959449_100273330_Schedule 6 _ BEND,EQ,BW,CS,A234- WPB,90DEG,SCH160,40MM, Item_70_M1711994562_100273330_Schedule 7 _ BEND,BW,CS,A234- WPB,90DEG,1.5D,SMLS,50MM, Item_80_M1712990032_100273330_Schedule 8 _ BEND,EQ,BW,CS,A234- WPA,90DEG,SCH160,65MM
Filtration of Transformer Oil of Transformers installed at Krishnashila Project and Repairing Rewinding of 100 KVA 25 KVA and 6.6 kV Auto Transformers required for Monsoon 2026 at Krishnashila Project
Custom Bid for Services - 200155124 BIENNIAL MAINTENANCE CONTRACT FOR COMPRESSED AIR SYSTEMS & AIR WASHER SYSTEMS OF STAGE-I & II UNITS IN OFFSITE AREA OF SSTPS Similar Category Operation and Maintenance Power House/Power Plant
Spiral Wound Gasket 314
Repair maintenance Testing and Commissioning of Field Switch Motor Starter and HT Feeders of Main Workshop substation s for Monsoon 2026 at Krishnashila Project
Repairing and Strengthening of HT overhead lines GOAB Switches Cable termination Kit Erection Dismantling Rerouting SAG tightening of HT overhead lines as required of any feeders of CHP Mines Field and Township for Monsoon 2026 as and when required..
Supply Installation and Commissioning Making of maintenance-free earthing with earthing pits Lighting Arrestors Surge Arrestors at various locations of mines and CHP feeders in view of safe and reliable operations as per requirement for monsoon 2026
Repairing of 10UPH6 10UPH4 Make Kirloskar and 03 Nos of Wilo MandP Pumps required for monsoon 2026 at Krishnashila Project
Fabrication of One New Pontoon and Repairing of 04 Nos existing pontoon floating drum structure including their shed and railings and fixing of mesh grizzly on existing and newly fabricated ladders/ stairs and its strengthening for monsoon 2026 at Kr
PR_ 100273895_ M2293993851_ WINCH, ELEC: WINCH MACHINE, 3T, 415V, 16MM_ Item-10_ Schedule-1, PR_ 100273895_ M2293993850_ WINCH, 5T, 22MM_ Item-20_ Schedule-2
Fabrication of universal joint moving units and MS Bends of different sizes and repairing of Non Return Valve Sluice Valve required for monsoon 2026 at Krishnashila Project
CBMC of Single Loading Computer Radiography System SLCRC at NTPC Rihand Hospital
Refrigerant Charging and maintaining of the air conditioning system in Operators Cabin of Dozers and Drills, Working at Bina Project.
Split Oil Sea l, Split oil seal Dust Guard for mech, O ring oil seal V15, Oil Seal Modified, Wear Sleave Jr Shaft, O Ring for pressure spring, Split Oil Seal, Split Oil Seal Dust Guard Viton, Oil Seal Modi U J HSG, Trunion Shaft Bushing STY 02, Oil Seal Sl No 6, Oil Seal 40X52X7, Oil Seal 55X75X9, Oil Seal 75X95X13 Nitrile Rubber, Oil Seal 16X28X7
Power Contactor Kit spare contact set ZL50 suitable for A50 contactors, Power Contactor Kit spare contact set ZL63 suitable for A63 contactors, Power Contactor Kit spare contact set ZL95 suitable for A95 contactors, Power Contactor Kit spare contact set ZL110 suitable for A110 contactors, Power Contactor Kit spare contact set ZL185 suitable for A185 contactors, Power Contactor Kit spare contact set ZL210 suitable for A210 contactors, OFF Delay Timer CT AHC 110V AC
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Power House Equipment; Service Provider
Polymer Surge Arrestor Rated Voltage 9 KV, Limit Switch Type PC904NP, Indoor Type Porcelain Surge Arrester For 11KV Dry Type Transformer, DC Supply ON OFF Switch, Diode Plate Assembly, Limit Switch For Spring Charge, LED Indicator Lamp Make ESSEN, Local Remote Selection Switch SPD10825BH30, MCB 2Pole 16 Amp 240V 415V, RE 302 Voltage Operated Auxiliary Relay, RYB NVIOA Voltage Indicator, High Speed Trip Relay 86, Oil Seal 120X180X13 Of TCK Make, Oil Seal 65X95X10 Of TCK Make, Neoprene Rubber Cord 2 Mm Dia, Neoprene Rubber Cord 3 Mm Dia, Neoprene Rubber Cord 5 Mm Dia, Neoprene Rubber Cord 6 Mm Dia, Neoprene Rubber Cord 7 Mm, Neoprene Rubber Cord, Size 09mm Dia For Ash Slurry Pump, Neoprene Rubber Sheet 1x2mtr Thick 3mm, Neoprene Rubber Sheet 1x2mtr Thick 4mm, Neoprene Rubber Sheet 1x2mtr Thick 5mm, Neoprene Rubber Bush Size OD 30 Mm, Expanded PTFE Super Seal Sealant Tape Size 15X3 Mm Length 20 Mtr, Polymer Surge Arrestor Rated Voltage 9 KV Discharge Current10 KA, Overload Relay Make SIEMENS
PROCUREMENT OF INTERNAL SPARES OF B3 400,B2 200 and B3 200 GEARBOX FORCHP STAGE-1 AT NTPC RIHAND
OVER CURRENT RELAY WITH INSTANTANEOUS ELEMENT CTU-62 CT SEC CURRENT: 1A CURRENT RATINGS FOR DEF TIME, BREAKER CONTACT MULTIPLE RELAY-52X Model No- VAJC11BF33A, AUX-220VDC
KASTURBA GANDHI BALIKA VIDYALAYA JUGAIL ME SAMPARK MARGE KA NIRMAN
LayingDismantling and jointing of 300 250 200 mm MS Pipeline and supply and fixing of miscellaneous control valves for monsoon including erection laying jointing of 5th pipeline from junction to both side pumps at Krishnashila Project
Construction of Barrel Syphon At km. 14.950 of Right Kanhar Canal
FEED ROLL SHAFT of RC Feeder, RCF Chain, Clutch assembly for R C Feeder, SS Grooved angle of 5 mm L 720mm, Complete Set of Sprocket Wheel, Sprocket Wheel small, Cover for Sprocket bearing, Gun Metal Seal Spindle Assy RCF, Brash Bush for R.C. Feeder, Brass Guide Bar for Hot Air gate
Facility Management Services - LumpSum Based - Industrial; O&M of Mechanical Work, Assistance in pump operation and day to day maintenance at Pump House of Kakri Project for One Year; Consumables to be provided by service provider (inclusive in contr..
Air filter regulator range 0-2 kg/cm2 with pressure gauge 0- 2.5 kg/cm2 Make SHAVO (As per Sample provided by user Division), Air filter regulator range 0-7 kg/cm2 with pressure gauge 0-10 kg/cm2 Make SHAVO (As per Sample provided by user Division), COPPER LUG PIN TYPE 1.5 MM2, insulated (As per Sample provided by user Division), FLEXIBLE (RUBBER) HOSE PIPE. ID=14 MM. OD= 20 MM (As per Sample provided by user Division), Seal kit for ID fan actuator (As per Sample provided by user Division)
KGBV STATIONARIES ITEMS
CONSTRUCTION OF MULTIPURPOSE HALL AT RAJKIYA HIGH SCHOOL BELAHATTHI DISTT- SONEBHDRA